These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 573350)

  • 1. Haemolysis due to formaldehyde-induced anti-N-like antibodies in haemodialysis patients.
    Fassbinder W; Frei U; Koch KM
    Klin Wochenschr; 1979 Jul; 57(13):673-9. PubMed ID: 573350
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Formaldehyde induced anti-N: a possible cause of renal graft failure.
    Gorst DW; Riches RA; Renton PH
    J Clin Pathol; 1977 Oct; 30(10):956-9. PubMed ID: 338635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The role of formaldehyde in the formation of haemodialysis-associated anti-N-like antibodies.
    Fassbinder W; Seidl S; Koch KM
    Vox Sang; 1978; 35(1-2):41-8. PubMed ID: 566486
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A specific immunohaemolytic anaemia induced by formaldehyde sterilisation of dialysers.
    Fassbinder W; Koch KM
    Contrib Nephrol; 1983; 36():51-67. PubMed ID: 6839775
    [No Abstract]   [Full Text] [Related]  

  • 5. Influence of reuse and of reuse sterilants on the first-use syndrome.
    Vanholder R; Ringoir S
    Artif Organs; 1987 Apr; 11(2):137-9. PubMed ID: 3496070
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Anti-Nform antibody in hemodialysis patients.
    Ng YY; Chow MP; Wu SC; Lyou JY; Harris DC; Huang TP
    Am J Nephrol; 1995; 15(5):374-8. PubMed ID: 7503135
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of formaldehyde-related antibodies encountered in hemodialysis patients at different stages of immunization.
    Lynen R; Rothe M; Gallasch E
    Vox Sang; 1983; 44(2):81-9. PubMed ID: 6402858
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Formation of anti-N-like antibodies in dialysis patients: effect of different methods of dialyzer rinsing to remove formaldehyde.
    Lewis KJ; Dewar PJ; Ward MK; Kerr DN
    Clin Nephrol; 1981 Jan; 15(1):39-43. PubMed ID: 6971198
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Allergy in chronic haemodialysis. 1. Double-blind intravenous challenge with formaldehyde.
    Bousquet J; Rivory JP; Maurice F; Skassa-Brociek W; Larrson P; Johansson SG; Florence P; Michel FB
    Clin Allergy; 1987 Nov; 17(6):499-506. PubMed ID: 3436030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Formaldehyde-related antibodies in hemodialysis patients.
    Sandler SG; Sharon R; Bush M; Stroup M; Sabo B
    Transfusion; 1979; 19(6):682-7. PubMed ID: 574996
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relationship between formaldehyde-related antibodies and cross-reacting anti-N-like antibodies in patients undergoing chronic haemodialysis.
    Sharon R
    J Clin Pathol; 1981 Jan; 34(1):41-3. PubMed ID: 7053234
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Specificity and possible origin of anti-N antibodies developed by patients undergoing chronic haemodialysis.
    Boettcher B; Nanra RS; Roberts TK; Mallan M; Watterson CA
    Vox Sang; 1976; 31(6):408-15. PubMed ID: 1007165
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Importance of anti-N-like antibodies in hemodialysis patients].
    Biondi C; Arriaga S; Piveta M; Solís E
    Sangre (Barc); 1993 Oct; 38(5):415-6. PubMed ID: 8140510
    [No Abstract]   [Full Text] [Related]  

  • 14. Relationship between dialyzer reuse and the presence of anti-N-like antibodies in chronic hemodialysis patients.
    Kaehny WD; Miller GE; White WL
    Kidney Int; 1977 Jul; 12(1):59-65. PubMed ID: 302361
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Incidence of the anti-N-like antibodies in the serum of patients dialyzed for chronic uremia].
    Illés M; Gál G
    Orv Hetil; 1991 Nov; 132(46):2531-2, 2535-6. PubMed ID: 1811202
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reduced antibody response in patients with chronic renal failure undergoing hemodialysis with formaldehyde sterilized units.
    Sharon R
    Transfusion; 1979; 19(6):754-5. PubMed ID: 574997
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components].
    Fulín P; Pokorný D; Slouf M; Vacková T; Dybal J; Sosna A
    Acta Chir Orthop Traumatol Cech; 2014; 81(1):33-9. PubMed ID: 24755055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prevention of anti-N like antibodies development with nonformaldehyde reuse procedure.
    Man NK; Lebkiri B; Polo P; de Sainte-Lorette E; Lemaire A; Funck-Brentano JL
    Proc Clin Dial Transplant Forum; 1980; 10():18-21. PubMed ID: 7346845
    [No Abstract]   [Full Text] [Related]  

  • 19. [The influence of formaldehyde, ethylene oxide, high pressure on the tension of silk sutures].
    Lin YL; Cai JH
    Zhonghua Hu Li Za Zhi; 1997 May; 32(5):259-60. PubMed ID: 9304983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stages of anti-N-like immunization: a further contribution to problems arising from anti-N-like antibodies in hemodialysis patients.
    Lynen R; Baumert H; Gallasch E
    Infusionstherapie; 1989 Dec; 16(6):267-72. PubMed ID: 2625365
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.