These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 5760754)

  • 1. Theory of gas-exchange units in artificial heart apparatuses: some problems. II. Some aspects of the control of the operation of foam-film type oxygenators determining their priming volume.
    Balabin EE; Kasulin VS; Super NA
    Biomed Eng (NY); 1968; 2(4):196-8. PubMed ID: 5760754
    [No Abstract]   [Full Text] [Related]  

  • 2. Some theoretical problems connected with gas-exchange mechanisms in artificial hearts. 1. Determination of minimum priming volume for foam-film type oxygenators.
    Super NA; Kasulin VS
    Biomed Eng (NY); 1968; 2(3):134-5. PubMed ID: 5760824
    [No Abstract]   [Full Text] [Related]  

  • 3. New design of heat exchanger for foam-film type oxygenators.
    Bobrov BS; Turchaninova TI
    Biomed Eng (NY); 1968; 2(3):160-2. PubMed ID: 5760831
    [No Abstract]   [Full Text] [Related]  

  • 4. [Comparative evaluation of membrane, bubble and foam-film oxygenators in artificial circulation during heart surgery].
    Shumakov VI; Pisarevskiĭ AA; Karasev AB; Naumov SP; Doletskiĭ AS
    Vestn Khir Im I I Grek; 1978 Jun; 120(6):15-21. PubMed ID: 675979
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculation of heat exchangers for cardiopulmonary bypass apparatus.
    Turchaninova TI
    Biomed Eng (NY); 1968; 2(4):199-202. PubMed ID: 5760755
    [No Abstract]   [Full Text] [Related]  

  • 6. [Regulation of gas metabolism in the oxygenators of artificial circulation apparatus].
    Fridman VE; Osipov VP
    Med Tekh; 1972; 5():9-15. PubMed ID: 4663472
    [No Abstract]   [Full Text] [Related]  

  • 7. The effects of solid and hollow fiber screens on gas exchange in membrane oxygenators.
    Eberhart RC; Curtis RM
    Trans Am Soc Artif Intern Organs; 1973; 19():66-71. PubMed ID: 4737353
    [No Abstract]   [Full Text] [Related]  

  • 8. [Artificial organs--developmental trends and problems].
    Bücherl ES
    Langenbecks Arch Chir; 1971 Dec; 329():354-9. PubMed ID: 5161686
    [No Abstract]   [Full Text] [Related]  

  • 9. Cardiac surgery with competely disposable membrane oxygenators.
    Landé AJ; Carlson RG; Ivey LA; Bloch JH; Lillehei CW
    Surg Forum; 1971; 22():185-6. PubMed ID: 5121349
    [No Abstract]   [Full Text] [Related]  

  • 10. Biomedical engineering provision of extracorporeal circulation under hyperbaric oxygenation conditions.
    Bokeriya LA; Khapii KK
    Biomed Eng (NY); 1974 Nov; 8(1):21-5. PubMed ID: 4412205
    [No Abstract]   [Full Text] [Related]  

  • 11. [Pneumatic control for the heart-lung machine].
    Weissbach G
    Z Exp Chir; 1972; 5(2):81-6. PubMed ID: 4680974
    [No Abstract]   [Full Text] [Related]  

  • 12. Partial and total circulatory support in the rat using a small heart-lung machine [proceedings].
    Proctor E
    J Physiol; 1978 Aug; 281():8P-10P. PubMed ID: 702408
    [No Abstract]   [Full Text] [Related]  

  • 13. A range of research oxygenators for experimental cardiopulmonary bypass.
    Proctor E; Fernando AR
    J Surg Res; 1973 Aug; 15(2):112-6. PubMed ID: 4725217
    [No Abstract]   [Full Text] [Related]  

  • 14. [Gas exchange and acid-base equilibrium in variations in ventilation and perfusion in a dog perfused with the heart-lung machine. With an appendix: On the theory of the oxygenator].
    LOESCHCKE HH; GERTZ KH; BUECHERL ES
    Pflugers Arch Gesamte Physiol Menschen Tiere; 1959; 270():121-46. PubMed ID: 14417900
    [No Abstract]   [Full Text] [Related]  

  • 15. Development and evaluation of a new hollow-fiber membrane oxygenator.
    Dutton RC; Mather FW; Walker SN; Lipps BJ; Rudy LW; Severinghaus JW; Edmunds LH
    Trans Am Soc Artif Intern Organs; 1971; 17():331-6. PubMed ID: 5158114
    [No Abstract]   [Full Text] [Related]  

  • 16. An ultrasonic detector for microgasemboli in a bloodflow line.
    Lubbers J; Van Den Berg JW
    Ultrasound Med Biol; 1977; 2(4):301-10. PubMed ID: 867565
    [No Abstract]   [Full Text] [Related]  

  • 17. Oscillating silicone membrane tubes: a new principle of extracorporeal respiration.
    Melrose DG; Burns N; Singh MP; Elliot RL; Read R; Williams FE; Becket J; Lamb MP; Adams JS
    Biomed Eng; 1972 Mar; 7(2):60-6. PubMed ID: 5020702
    [No Abstract]   [Full Text] [Related]  

  • 18. [Open heart surgery in infancy using a new heart-lung machine of own construction].
    Turina M
    Ther Umsch; 1973 Dec; 30(12):858-63. PubMed ID: 4764641
    [No Abstract]   [Full Text] [Related]  

  • 19. A low priming volume oxygenator for bloodless priming in cardiopulmonary bypass.
    Proctor E; De Bono AH
    Thorax; 1965 Nov; 20(6):540-4. PubMed ID: 5862754
    [No Abstract]   [Full Text] [Related]  

  • 20. New method of complete and auxiliary extracorporeal blood circulation.
    Brazhnikov EM; Mamlina VI; Pisarevskii AA; Russiyan EK; Cherepnina OO
    Biomed Eng (NY); 1975 Jan; 8(2):73-5. PubMed ID: 122782
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.