These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

83 related articles for article (PubMed ID: 5765713)

  • 1. A cyclotron produced 81Rb-81mKr generator and its uses in gamma-camera studies.
    Jones T; Clark JC
    Br J Radiol; 1969 Mar; 42(495):237. PubMed ID: 5765713
    [No Abstract]   [Full Text] [Related]  

  • 2. A krypton-81m generator for organ ventilation and perfusion investigations.
    van Zyl WH; Kleynhans PH; Lötter MG; Ungerer MJ; van Aswegen A; Minnaar PC; Iturralde M; Weich DJ
    S Afr Med J; 1979 Jun; 55(23):920-4. PubMed ID: 472931
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Initial experiences with nuclear medicine diagnostic use of the 81Rb/81mKr generator of the ZfK Rossendorf].
    Franke WG; Woller P; Hliscs R; Beyer GJ; Hilbert K; Kühne A; Kroemer B; Löffler I
    Radiobiol Radiother (Berl); 1982; 23(3):309-20. PubMed ID: 7178466
    [No Abstract]   [Full Text] [Related]  

  • 4. Lung function studies using short-lived 81mKr and the scintillation camera.
    Yano Y; McRae J; Anger HO
    J Nucl Med; 1970 Nov; 11(11):674-9. PubMed ID: 5528162
    [No Abstract]   [Full Text] [Related]  

  • 5. [Clinical evaluation of 81Rb-81mKr generator as a ventilation and perfusion imaging agent (author's transl)].
    Fukuchi M; Hyodo K; Tachibana K; Onoue K; Kido A; Morita T; Maeda Y; Hamada K; Nagai K
    Kaku Igaku; 1979 Aug; 16(5):757-62. PubMed ID: 537238
    [No Abstract]   [Full Text] [Related]  

  • 6. Myocardial perfusion measured by dual-isotope acquisition of 81rubidium/81mkrypton: an experimental verification of the method.
    Stoll HP; Bay W; Vogel W; Ozbek C; Hanser A; Schieffer H; Harbauer G
    Basic Res Cardiol; 1994; 89(4):354-65. PubMed ID: 7826309
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 81mKr generator and its uses in cardiopulmonary studies with the scintillation camera.
    Jones T; Clark JC; Hughes JM; Rosenzweig DY
    J Nucl Med; 1970 Mar; 11(3):118-24. PubMed ID: 5416925
    [No Abstract]   [Full Text] [Related]  

  • 8. Measurements of the rubidium isotopic activities and the elution parameters of 81mKr generators using a standardized 114mIn source.
    Williams NR; Childs PO; Causer DA; Mostafa AB
    Eur J Nucl Med; 1985; 10(1-2):33-8. PubMed ID: 3979408
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new type of 81Rb-81mKr generator for medical use.
    Beyer GJ; Ravn HL; Huang Y
    Int J Appl Radiat Isot; 1984 Nov; 35(11):1075-6. PubMed ID: 6526523
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Trial preparation and evaluation of a 81mKr-generator for medical use].
    Kato M; Hazue M
    Radioisotopes; 1977 Jan; 26(1):25-9. PubMed ID: 577019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow.
    Stoll HP; Huwer H; Vollmar B; Bialy J; Schmitt M; Peters JW; Sommer A; Hellwig N; Bonaventura K; Menger MD; Schieffer H
    J Nucl Cardiol; 2000; 7(3):255-62. PubMed ID: 10888397
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Letter: The preparation of 81Rb in high specific activity quantities and its use in a 81Rb-81mKr generator.
    Mayron LW; Kaplan E; Friedman AM; Gindler JE
    Int J Appl Radiat Isot; 1974 May; 25(5):237-8. PubMed ID: 4833457
    [No Abstract]   [Full Text] [Related]  

  • 13. Administered dosage and effective dose estimated from 81Rb-rubidium hydroxide for lung ventilation scintigraphy using 81mKr noble gas.
    Kamiya T; Iimori T; Maeda Y; Yada N; Hayashi N; Iguchi H; Narita M
    Radiat Prot Dosimetry; 2024 Feb; 200(2):149-154. PubMed ID: 37987214
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Unilateral kidney blood flow measurement using the 81Rb/81mKr ratio.
    van Herk G; de Zeeuw D
    Contrib Nephrol; 1978; 11():67-72. PubMed ID: 699597
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 81mKr gas generator for lung ventilation study.
    Koyama T; Koyama T; Hirokawa Y; Yoshizawa Y; Noma H; Horiguchi T; Kiso Y; Hasai H; Takemi H
    Eur J Nucl Med; 1980 Dec; 5(6):481-6. PubMed ID: 7460973
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous radionuclide generation. I. Production and evaluation of a 81mKr minigenerator.
    Colombetti LG; Mayron LW; Kaplan E; Barnes WE; Friedman AM; Gindler JE
    J Nucl Med; 1974 Oct; 15(10):868-73. PubMed ID: 4421402
    [No Abstract]   [Full Text] [Related]  

  • 17. Comparison of four commercially available 81Rb-81mKr generators: quality testing using a breathing lung phantom.
    Camps JA; Blokland JA; Blok D; Pauwels EK
    Int J Rad Appl Instrum B; 1990; 17(3):269-72. PubMed ID: 2341281
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Definition of myocardial perfusion by continuous infusion of krypton-81m.
    Kaplan E; Mayron LW; Friedman AM; Gindler JE; Frazin L; Moran JM; Loeb H; GUNNAR RM
    Am J Cardiol; 1976 May; 37(6):878-84. PubMed ID: 1266754
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A 81Rb/81mKr generator made by ion implantation.
    Beyer GJ; Ravn HL
    Int J Rad Appl Instrum A; 1991; 42(2):141-2. PubMed ID: 1648034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous radionuclide generation. II. Scintigraphic definition of capillary exchange by rapid decay of 81mKr and its applications.
    Kaplan E; Mayron LW; Barnes WE; Colombetti LG; Friedman AM; Gindler JE
    J Nucl Med; 1974 Oct; 15(10):874-9. PubMed ID: 4421403
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.