These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 5781432)

  • 1. An inexpensive high-resolution densitometer for disc electrophoresis.
    Petrakis PL
    Anal Biochem; 1969 Apr; 28(1):416-27. PubMed ID: 5781432
    [No Abstract]   [Full Text] [Related]  

  • 2. [Self-recording densitometer for the disc electrophoregrams].
    Lutsik MD; Kokodyniak IP; Krishchishin NV; Kirilenko NV
    Lab Delo; 1977; (8):506-7. PubMed ID: 72868
    [No Abstract]   [Full Text] [Related]  

  • 3. [Photoelectrocolorimeter attachment for electrophoretogram densitometry].
    Elchiev IaIa
    Lab Delo; 1981; (1):47. PubMed ID: 6163024
    [No Abstract]   [Full Text] [Related]  

  • 4. A microprocessor-based scanning densitometer.
    Widdoss AS; Ferris CD
    Biomed Sci Instrum; 1978 Apr 17-18; 14():115-9. PubMed ID: 687720
    [No Abstract]   [Full Text] [Related]  

  • 5. High-resolution densitometry: analysis of stained albumin bands as a model for electrophoresis of serum proteins.
    Epstein DJ; Neeley WE
    Clin Chem; 1984 Jun; 30(6):847-50. PubMed ID: 6202439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of the results of polyacrylamide gel disc electrophoresis on the BIAN-2 densitometer].
    Alekhina SM
    Lab Delo; 1979; (4):243-4. PubMed ID: 85795
    [No Abstract]   [Full Text] [Related]  

  • 7. [Constant current and tension mains set for microdisk electrophoresis].
    Neuhoff V; Mühlberg B; Meier J
    Arzneimittelforschung; 1967 May; 17(5):649. PubMed ID: 5631602
    [No Abstract]   [Full Text] [Related]  

  • 8. Gel electrophoresis destaining apparatus.
    Peterson JI
    Anal Biochem; 1968 Oct; 25(1):257-9. PubMed ID: 4178698
    [No Abstract]   [Full Text] [Related]  

  • 9. [Apparatus for electrophoresis in a vertical gel block].
    Gineĭtis AA
    Tsitologiia; 1969; 11(3):396-7. PubMed ID: 5404199
    [No Abstract]   [Full Text] [Related]  

  • 10. [Photoelectric densitometer and its application in evaluation of results of paper electrophoresis].
    SOKOLOV AA; VLASENKO VI; GURVICH AE; STAROSEL'TSEVA LK
    Vopr Med Khim; 1956; 2(3):222-8. PubMed ID: 13352891
    [No Abstract]   [Full Text] [Related]  

  • 11. [Preparative electrophoresis in sucrose density gradient].
    Kobozev GV; Azhitskiĭ GIu
    Ukr Biokhim Zh; 1968; 40(2):217-21. PubMed ID: 5696403
    [No Abstract]   [Full Text] [Related]  

  • 12. A rapid, inexpensive, quantitative, general-purpose densitometer and its application to one-dimensional gel electrophoretograms.
    Haselgrove JC; Lyons G; Rubenstein N; Kelly A
    Anal Biochem; 1985 Nov; 150(2):449-56. PubMed ID: 3841468
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simplified technique for preparative disc electrophoresis. II. Further improvements in apparatus and some details of performance.
    Sulitzeanu D; Slavin M; Yecheskeli E
    Anal Biochem; 1967 Oct; 21(1):57-67. PubMed ID: 6062774
    [No Abstract]   [Full Text] [Related]  

  • 14. [Use of the BIAN-170 densitometer and the BIAN-120 colorimeter in laboratory practice].
    Tukachinskiĭ SE
    Lab Delo; 1972; 2():74-7. PubMed ID: 4112082
    [No Abstract]   [Full Text] [Related]  

  • 15. A new device for slicing polyacrylamide gels.
    Goldberger RF
    Anal Biochem; 1968 Oct; 25(1):46-54. PubMed ID: 4883829
    [No Abstract]   [Full Text] [Related]  

  • 16. An elution device for analytical-scale polyacrylamide gel electrophoresis.
    Ray DK; Troisi RM; Rappaport HP
    Anal Biochem; 1969 Nov; 32(2):322-30. PubMed ID: 4919538
    [No Abstract]   [Full Text] [Related]  

  • 17. [Integrator for densitometers and microphotometers for the quantitative processing of electrophoregrams and chromatograms].
    Vinogradov GA; Silkin NF
    Lab Delo; 1979; (10):631-2. PubMed ID: 94139
    [No Abstract]   [Full Text] [Related]  

  • 18. A double-beam recording spectrodensitometer.
    Staynov D; Stainov G
    J Sci Instrum; 1969 Dec; 2(12):1114-5. PubMed ID: 5361298
    [No Abstract]   [Full Text] [Related]  

  • 19. Discontinuous electrophoresis of pepsin and pepsinogen in thin sheets of polyacrylamide gel.
    Cunningham L; Rasch EM; Lewis AL; Heitsch R
    J Histochem Cytochem; 1970 Dec; 18(12):853-61. PubMed ID: 4100580
    [No Abstract]   [Full Text] [Related]  

  • 20. A vertical microsystem for discontinuous electrophoresis of insect tissue proteins using thin sheets of polyacrylamide gel.
    Been AC; Rasch EM
    J Histochem Cytochem; 1972 May; 20(5):368-84. PubMed ID: 4336810
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.