These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. [Ventricular fibrillation after implantation of an internal pacemaker]. Bertrand M; Cabrol C; Guiraudon G; Conso C; Léon Presse Med (1893); 1967 Jun; 75(28):1455-7. PubMed ID: 6025532 [No Abstract] [Full Text] [Related]
5. [Cathode stimulation as a cause of ventricular fibrillation induced by a pacemaker. Report of a case]. Vera Almazán A; Alonso Pulpón L; Lezaun Burgui R; Puente Arús A; Teresa Galván E; Artaza Andrade M Rev Esp Cardiol; 1980; 33(6):617-20. PubMed ID: 7209090 [No Abstract] [Full Text] [Related]
7. Abnormal ECG following insertion of a temporary pacing wire. Thomas MD; Hildick-Smith D Heart; 2006 Aug; 92(8):1016. PubMed ID: 16844849 [No Abstract] [Full Text] [Related]
8. [Ventricular fibrillation through pacemaker tachycardia]. Diederich KW; Severidt HJ; Glatzel KH; Mühlberg B Z Kreislaufforsch; 1966 Dec; 55(12):1257-64. PubMed ID: 5994574 [No Abstract] [Full Text] [Related]
9. [Syncopal attacks due to ventricular tachyarrhythmias ("torsade de pointe type") in a patient with a PM of hysteresis type (author's transl)]. Speca G; Di Sabatino P; Potena A G Ital Cardiol; 1978; 8 Suppl 1():283-8. PubMed ID: 754966 [TBL] [Abstract][Full Text] [Related]
10. Strength-duration curves for cardiac pacemaking and ventricular fibrillation. Jones M; Geddes LA Cardiovasc Res Cent Bull; 1977; 15(4):101-12. PubMed ID: 884694 [No Abstract] [Full Text] [Related]
11. Induced ventricular tachycardia and fibrillation by a fixed rate pacemaker. The fibrillation threshold in humans. Case report. Sallam IA J Cardiovasc Surg (Torino); 1973; 14(4):443-5. PubMed ID: 4732062 [No Abstract] [Full Text] [Related]
12. [Abnormal pacing following defibrillation - exit block after microdislocation of the electrode (author's transl)]. Wehr M; Schmitt CG; Köhler F; Crayen P Z Kardiol; 1980 Dec; 69(12):840-4. PubMed ID: 7281867 [TBL] [Abstract][Full Text] [Related]
14. Ventricular fibrillation induced by double premature ventricular pacing stimuli in a dual-chamber pacemaker with AutoCapture. Sweeney MO; Porkolab FL Heart Rhythm; 2009 Mar; 6(3):429-32. PubMed ID: 19251223 [No Abstract] [Full Text] [Related]
15. Ventricular arrhythmia; sign of myocardial perforation by transvenous pacemaker electrode. Quan K; Amelkin SA; Wesolowski SA N Y State J Med; 1972 Aug; 72(15):1986-90. PubMed ID: 4506218 [No Abstract] [Full Text] [Related]
16. [Harmful interference between preoperative prophylactic cardiac pacemaker and cutting diathermy. Case report]. Protin F; Dodinot B; Lefèvre JC; Laxenaire MC Ann Anesthesiol Fr; 1979; 20(2):127-30. PubMed ID: 38707 [TBL] [Abstract][Full Text] [Related]
17. Ventricular fibrillation induced by a unipolar implanted pacemaker (cathodal stimulation). Seipel L; Bub E; Loogen F Am Heart J; 1976 Dec; 92(6):810-1. PubMed ID: 998490 [No Abstract] [Full Text] [Related]