These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 591030)

  • 21. Unstable trochanteric fractures. A comparative analysis of four methods of internal fixation.
    Jensen JS; Sonne-Holm S; Tøndevold E
    Acta Orthop Scand; 1980 Dec; 51(6):949-62. PubMed ID: 7211302
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Comparison of the Ender's nailing and Dynamic Hip Screw (DHS) fixation in the treatment of trochanteric fractures in elderly patients].
    Sliwka A; Zgoda M; Górski R; Purski K; Wasilewski P; Górecki A
    Chir Narzadow Ruchu Ortop Pol; 2006; 71(4):269-73. PubMed ID: 17455526
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail.
    Park SY; Yang KH; Yoo JH; Yoon HK; Park HW
    J Trauma; 2008 Oct; 65(4):852-7. PubMed ID: 18849802
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Gamma nail in the treatment of closed trochanteric fractures. Results and indications of 121 cases.
    Kempf I; Grosse A; Taglang G; Favreul E
    Orthop Traumatol Surg Res; 2014 Feb; 100(1):75-83. PubMed ID: 24456767
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A prospective randomized study of the use of sliding hip screws and Ender nails for trochanteric fractures of the femur.
    Stark A; Broström LA; Barrios C; Walheim G; Olsson E
    Int Orthop; 1992; 16(4):359-62. PubMed ID: 1473889
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Hemiarthroplasty for treatment of comminuted trochanteric fractures in elderly patients].
    Szczesny G; Górski R; Biedrzycki J; Górecki A
    Chir Narzadow Ruchu Ortop Pol; 2009; 74(6):337-40. PubMed ID: 20201331
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mini-invasive nail versus DHS to fix pertrochanteric fractures: a case-control study.
    Foulongne E; Gilleron M; Roussignol X; Lenoble E; Dujardin F
    Orthop Traumatol Surg Res; 2009 Dec; 95(8):592-8. PubMed ID: 19945367
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Proximal femoral nails antirotation, Gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: A meta-analysis.
    Ma KL; Wang X; Luan FJ; Xu HT; Fang Y; Min J; Luan HX; Yang F; Zheng H; He SJ
    Orthop Traumatol Surg Res; 2014 Dec; 100(8):859-66. PubMed ID: 25453927
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [From the nail/plate to the dynamic hip screw--example of a generation change in implants for para-articular femoral fractures].
    Kohlmann H; Vécsei V; Neugebauer G; Gottsauner-Wolf F
    Wien Klin Wochenschr; 1987 Oct; 99(19):677-82. PubMed ID: 3687027
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of nail-plate fixation and Ender's nailing for intertrochanteric fractures.
    Hall G; Ainscow DA
    J Bone Joint Surg Br; 1981 Feb; 63-B(1):24-8. PubMed ID: 7204468
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ender nailing in intertrochanteric fractures of the femur.
    Waddell JP
    Instr Course Lect; 1984; 33():218-21. PubMed ID: 6546103
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Comparative results of osteosynthesis of trochanteric fractures with Ender elastic nails and 130 degree angle nail plates].
    Lanfranchi R; Contro E; Spina F
    Chir Organi Mov; 1982; 68(2):225-34. PubMed ID: 7187883
    [No Abstract]   [Full Text] [Related]  

  • 33. Anteversion measurements in trochanteric fractures of the femur.
    Herrlin K; Egund N; Andersson S; Wallöe A
    Acta Radiol Diagn (Stockh); 1982; 23(4):409-13. PubMed ID: 7158404
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Ender nail with interlocking mechanism or dynamic hip screw in pertrochanteric fractures? A prospective study extending its limits].
    Muller B; Bonnaire F; Heckel T; Jaeger JH; Kempf I; Kuner EH
    Unfallchirurgie; 1994 Feb; 20(1):18-29. PubMed ID: 8154055
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Intertrochanteric fractures: a comparison between fixation with a two-piece nail plate and Ender's nails.
    Hayward SJ; Lowe LW; Tzevelekos S
    Int Orthop; 1983; 7(3):153-8. PubMed ID: 6368412
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Treatment of femur shaft fractures in children with Ender nails].
    Träger D; Rode P
    Aktuelle Traumatol; 1988 Aug; 18(4):173-6. PubMed ID: 2905582
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Surgical treatment of unstable trochanteric fractures of the femur. I. Evaluation of the surgical treatment of trochanteric fractures of the femur using angular nails].
    Frańczuk B
    Przegl Lek; 1989; 46(2):292-6. PubMed ID: 2772232
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Critical analysis of Ender nailing in the treatment of trochanteric fractures.
    Jensen JS; Sonne-Holm S
    Acta Orthop Scand; 1980 Oct; 51(5):817-25. PubMed ID: 7468175
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Surgical treatment of unstable trochanteric fractures of the femur. IV. Evaluation of the surgical treatment of trochanteric fractures of the femur using intramedullary Y nails].
    Frańczuk B
    Przegl Lek; 1989; 46(5):433-9. PubMed ID: 2772243
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.
    Vallier HA; Cureton BA; Patterson BM
    J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.