These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
99 related articles for article (PubMed ID: 591346)
1. Neutron dose monitoring using a multiple lithium fluoride TLD badge. Otterberg JE; Cipolla SJ Health Phys; 1977 Sep; 33(3):256-8. PubMed ID: 591346 [No Abstract] [Full Text] [Related]
2. A TLD fast-neutron dose monitor suitable for clinical use. Cunningham DE Health Phys; 1982 Aug; 43(2):259-63. PubMed ID: 7129882 [No Abstract] [Full Text] [Related]
3. [Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values]. Meissner P Strahlentherapie; 1985 Feb; 161(2):102-6. PubMed ID: 3975938 [TBL] [Abstract][Full Text] [Related]
4. Analytical modeling of thermoluminescent albedo detectors for neutron dosimetry. Glickstein SS Health Phys; 1983 Feb; 44(2):103-14. PubMed ID: 6826377 [TBL] [Abstract][Full Text] [Related]
5. [The use of thermoluminescent dosimetry systems in individual dosimetry and environmental monitoring]. Burgkhardt B Strahlentherapie; 1985 Feb; 161(2):84-5. PubMed ID: 3975943 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of the fast neutron dose equivalent using the thermal neutron response of LiF TL material. Hankins DE Health Phys; 1976 Aug; 31(2):170-3. PubMed ID: 972057 [No Abstract] [Full Text] [Related]
7. Thermoluminescent response of LiF dosimeters to fast neutrons produced with 25--60-MeV protons on thick beryllium target. Momeni MH Health Phys; 1974 Aug; 27(2):217-9. PubMed ID: 4443265 [No Abstract] [Full Text] [Related]
8. [Clinical dosimetric properties of the TLD-300 thermoluminescent dosimetry detector and its use for measuring spatial dose distribution in patient radiation planning]. Olthoff-Münter K; Baumhoer W Strahlentherapie; 1985 Feb; 161(2):98-101. PubMed ID: 3975947 [TBL] [Abstract][Full Text] [Related]
9. Fading of unannealed LiF(TLD-600) for thermal neutrons and gamma-rays. Johnson TL; Luersen RB Health Phys; 1980 May; 38(5):853-6. PubMed ID: 7390850 [No Abstract] [Full Text] [Related]
10. Neutron dose precision using LiF TLD. Zeman GH; Snyder GI Health Phys; 1979 Jan; 36(1):75-6. PubMed ID: 422384 [No Abstract] [Full Text] [Related]
11. The response of thermoluminescence dosemeters to fast (14-7 MeV) and thermal neutrons. Rossiter MJ; Lewis VE; Wood JW Phys Med Biol; 1977 Jul; 22(4):731-6. PubMed ID: 887651 [TBL] [Abstract][Full Text] [Related]
12. On the reassessment of thermal neutron doses in TLD-100 by measuring the residual dose. Abraham A; Weinstein M; German U; Alfassi ZB Radiat Prot Dosimetry; 2007; 126(1-4):524-7. PubMed ID: 17507383 [TBL] [Abstract][Full Text] [Related]
13. Personnel neutron dosimetry by means of cellulose nitrate film combined with LiF as both radiator and TLD. Tymons BJ; Tnyn JW Health Phys; 1977 Jun; 32(6):547-9. PubMed ID: 881355 [No Abstract] [Full Text] [Related]
14. Study of a method based on TLD detectors for in-phantom dosimetry in BNCT. Gambarini G; Klamert V; Agosteo S; Birattari C; Gay S; Rosi G; Scolari L Radiat Prot Dosimetry; 2004; 110(1-4):631-6. PubMed ID: 15353721 [TBL] [Abstract][Full Text] [Related]
15. A comparison of two methods of in vivo dosimetry for a high energy neutron beam. Blake SW; Bonnett DE; Finch J Br J Radiol; 1990 Jun; 63(750):476-81. PubMed ID: 2379072 [TBL] [Abstract][Full Text] [Related]
16. Calibration and testing of a TLD dosemeter for area monitoring. Buchillier T; Aroua A; Bochud F; Schuler C; Stritt N; Valley JF; Wernli C Radiat Prot Dosimetry; 2004; 110(1-4):705-10. PubMed ID: 15353735 [TBL] [Abstract][Full Text] [Related]
17. Neutron dosimetry with TL albedo dosemeters at high energy accelerators. Haninger T; Fehrenbacher G Radiat Prot Dosimetry; 2007; 125(1-4):361-3. PubMed ID: 17766258 [TBL] [Abstract][Full Text] [Related]
19. Thermoluminescence dosimetry of a thermal neutron field and comparison with Monte Carlo calculations. Fernandes AC; Santos JP; Kling A; Marques JG; Gonçalves IC; Carvalho AF; Santos L; Cardoso J; Osvay M Radiat Prot Dosimetry; 2004; 111(1):35-9. PubMed ID: 15367765 [TBL] [Abstract][Full Text] [Related]
20. Study of the neutron field in the vicinity of an unshielded PET cyclotron. Méndez R; Iñiguez MP; Martí-Climent JM; Peñuelas I; Vega-Carrillo HR; Barquero R Phys Med Biol; 2005 Nov; 50(21):5141-52. PubMed ID: 16237246 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]