These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
97 related articles for article (PubMed ID: 591397)
1. Improvement of the skin sparing characteristics of the Clinac 4 by the use of leaded glass electron filters. Ames TE; Saylor W; Dillard M Int J Radiat Oncol Biol Phys; 1977; 2(9-10):1027-9. PubMed ID: 591397 [No Abstract] [Full Text] [Related]
2. [Electron and low-energy photon contamination of the radiation beam from a Theratron 780 cobalt unit]. Groenewald WA; van der Merwe EJ S Afr Med J; 1980 Oct; 58(14):568-70. PubMed ID: 7423296 [TBL] [Abstract][Full Text] [Related]
3. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays. Gagnon WF; Peterson MD Radiology; 1978 Jun; 127(3):785-8. PubMed ID: 663179 [TBL] [Abstract][Full Text] [Related]
4. Skin dose measurements for head and neck radiotherapy. Fiorino C; Cattaneo GM; del Vecchio A; Longobardi B; Signorotto P; Calandrino R; Fossati V; Volterrani F Med Phys; 1992; 19(5):1263-6. PubMed ID: 1435607 [TBL] [Abstract][Full Text] [Related]
5. Effects of filters and wedges on skin sparing and gamma/neutron dose ratios in neutron teletherapy. Smathers J; Graves R; Almond P; Otte V; Grant W Med Phys; 1980; 7(1):65-7. PubMed ID: 6767906 [TBL] [Abstract][Full Text] [Related]
6. Effect of block trays on skin dose in radiotherapy. Butson MJ; Mathur JN; Metcalfe PE Australas Phys Eng Sci Med; 1996 Dec; 19(4):248-51. PubMed ID: 9060211 [TBL] [Abstract][Full Text] [Related]
7. Improvement in the depth-dose characteristics of a 10 MV photon beam with electron filters. LaRiviere PD Phys Med Biol; 1985 Nov; 30(11):1260-1. PubMed ID: 4080823 [No Abstract] [Full Text] [Related]
8. [Physico-technical aspects of total skin irradiation with high-intensity-dose electrons]. Scielzo G; Grillo Ruggieri F; Brunelli B; Bistolfi F Radiol Med; 1990 Oct; 80(4 Suppl 1):147-50. PubMed ID: 2251406 [TBL] [Abstract][Full Text] [Related]
9. First application of total skin electron beam irradiation in Greece: setup, measurements and dosimetry. Platoni K; Diamantopoulos S; Panayiotakis G; Kouloulias V; Pantelakos P; Kelekis N; Efstathopoulos E Phys Med; 2012 Apr; 28(2):174-82. PubMed ID: 21515082 [TBL] [Abstract][Full Text] [Related]
10. Skin exit dose in megavoltage x-ray beams determined by means of a plane parallel ionization chamber (Attix chamber). Kron T; Ostwald P Med Phys; 1995 May; 22(5):577-8. PubMed ID: 7643795 [No Abstract] [Full Text] [Related]
12. [Individual field shaping in rotational irradiation]. Bruggmoser G; Hodapp N; Nanko N; Wannenmacher M; Neher A Strahlenther Onkol; 1987 Nov; 163(11):734-8. PubMed ID: 3686336 [TBL] [Abstract][Full Text] [Related]
13. An update of the depth dose of the Clinac-6X. Ekstrand KE; Dixon RL Int J Radiat Oncol Biol Phys; 1978; 4(7-8):757-8. PubMed ID: 101493 [No Abstract] [Full Text] [Related]
14. Dosimetry measurements and analyses of 10-MV x rays for Clinac-18. Wu A; Leavitt DD; Campbell DW Med Phys; 1977; 4(1):71-3. PubMed ID: 840194 [TBL] [Abstract][Full Text] [Related]
15. Application of a radiotherapy stimulator for imaging of body cross sections. Webb S; Lillicrap SC; Steere H Br J Radiol; 1977 Feb; 50(590):152-3. PubMed ID: 831943 [No Abstract] [Full Text] [Related]
16. [Preliminary evaluation of the clinical use of a system for intraoperative radiotherapy with electrons (IORT)]. Grillo Ruggieri F; Parietti E; Brunelli B; Scielzo G Radiol Med; 1990 Oct; 80(4 Suppl 1):104-8. PubMed ID: 2251395 [TBL] [Abstract][Full Text] [Related]