These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Timing device used at radiation dosimeter calibration. Samuelson G; Bengtsson LG Health Phys; 1975 Apr; 28(4):464-6. PubMed ID: 1120679 [No Abstract] [Full Text] [Related]
6. [An instrument for localization of brain neoplasms during surgery with the use of P32]. Desiatnikov VM; Kotliarov EV; Liass FM Med Radiol (Mosk); 1968 Nov; 13(11):41-4. PubMed ID: 5742630 [No Abstract] [Full Text] [Related]
7. [A comparison of the performances between the ionization chamber dosimeters used in radiation therapy]. Li GQ; Lin MY Zhongguo Yi Liao Qi Xie Za Zhi; 2002 Jul; 26(4):301-2, 304. PubMed ID: 16104292 [TBL] [Abstract][Full Text] [Related]
9. In-phantom dose imaging with polymer gel layer dosimeters. Vanossi E; Carrara M; Gambarini G; Negri A; Mariani M Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S195-8. PubMed ID: 19375935 [TBL] [Abstract][Full Text] [Related]
10. [An electrostatic charge device for the DK-O.2 dosimeter]. Sokolov VM Vestn Rentgenol Radiol; 1966; 41(1):57-8. PubMed ID: 5984694 [No Abstract] [Full Text] [Related]
11. Effects of threshold voltage variability on the characteristics of high sensitivity metal-oxide-semiconductor dosimeters. Sarrabayrouse G; Siskos S; Boukabache A Appl Radiat Isot; 2005; 63(5-6):775-7. PubMed ID: 15975805 [TBL] [Abstract][Full Text] [Related]
13. Measurement of high doses with glass dosimeters. Freytag E Health Phys; 1971 Jan; 20(1):93-4. PubMed ID: 5559159 [No Abstract] [Full Text] [Related]
14. In-phantom imaging of all dose components in boron neutron capture therapy by means of gel dosimeters. Gambarini G; Colli V; Gay S; Petrovich C; Pirola L; Rosi G Appl Radiat Isot; 2004 Nov; 61(5):759-63. PubMed ID: 15308140 [TBL] [Abstract][Full Text] [Related]
16. Phantoms for calibrating albedo neutron dosimeters. Hankins DE Health Phys; 1980 Sep; 39(3):580-4. PubMed ID: 7440176 [No Abstract] [Full Text] [Related]
17. A constant-power circuit for heating thermoluminescent dosimeters. Attix FH Health Phys; 1967 Jun; 13(6):656-7. PubMed ID: 6035218 [No Abstract] [Full Text] [Related]
18. The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters. De Deene Y; Pittomvils G; Visalatchi S Phys Med Biol; 2007 May; 52(10):2719-28. PubMed ID: 17473347 [TBL] [Abstract][Full Text] [Related]
19. The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels. De Deene Y; Vergote K; Claeys C; De Wagter C Phys Med Biol; 2006 Feb; 51(3):653-73. PubMed ID: 16424587 [TBL] [Abstract][Full Text] [Related]