These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 599889)

  • 21. A method for sampling representative muscular venous blood during exercise in rats.
    Pagés T; Fernández JA; Adán C; Gámez A; Viscor G; Palacios L
    Lab Anim; 1993 Apr; 27(2):171-5. PubMed ID: 8501900
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Recirculation of urea and dialysis efficiency using dual-lumen dialysis catheters in various locations: may the venous lumen of the catheter be used as the arterial lumen and vice versa?].
    Sefer S; Kes P; Degoricija V; Heinrich B; Vrsalović M
    Lijec Vjesn; 2003; 125(1-2):1-5. PubMed ID: 12812016
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A novel bile duct cannulation method with tail cuff exteriorization allowing continuous intravenous infusion and enterohepatic recirculation in the unrestrained rat.
    van Wijk H; Donachie P; Mann DL; McMahon H; Robb D
    Lab Anim; 2001 Oct; 35(4):325-33. PubMed ID: 11669316
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ileal cannulation and associated complications in dogs.
    Hill RC; Ellison GW; Burrows CF; Bauer JE; Carbia B
    Lab Anim Sci; 1996 Feb; 46(1):77-80. PubMed ID: 8699825
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A simple catheterization from the ear vein into the jugular vein for sequential blood sampling from unrestrained pigs.
    Niiyama M; Yonemichi H; Harada E; Syuto B; Kitagawa H
    Jpn J Vet Res; 1985 Apr; 33(1-2):1-9. PubMed ID: 4032920
    [No Abstract]   [Full Text] [Related]  

  • 26. Complications of ileal cannulation in cats.
    Mawby DI; Mathew AG; Mears EA; Moyers TD; Krahwinkel DJ
    Lab Anim Sci; 1999 Aug; 49(4):406-10. PubMed ID: 10480646
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Vascular access recirculation in hemodialysis patients with two noncuffed, single-lumen, jugular catheters in the same jugular vein.
    Kovac J; Buturović-Ponikvar J; Ponikvar R
    Ther Apher Dial; 2009 Aug; 13(4):350-3. PubMed ID: 19695073
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Simple technique for chronic venous catheterization of swine.
    Ford JJ; Maurer RR
    Lab Anim Sci; 1978 Oct; 28(5):615-8. PubMed ID: 723225
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An all-plastic double-lumen catheter for continuous blood sampling.
    Gander RE; Albisser AM; Botz CK; Leibel BS; Zingg W
    Med Instrum; 1975; 9(4):187-8. PubMed ID: 1143121
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Rumen cannulation: procedure and use of a cannulated bovine.
    Laflin SL; Gnad DP
    Vet Clin North Am Food Anim Pract; 2008 Jul; 24(2):335-40, vii. PubMed ID: 18471573
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Preparation of a chronic gastric fistula in the rat.
    Paré WP; Isom KE; Vincent GP; Glavin GB
    Lab Anim Sci; 1977 Apr; 27(2):244-7. PubMed ID: 853711
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Objective evaluation of the efficacy of various venous cannulas.
    Arom KV; Ellestad C; Grover FL; Trinkle JK
    J Thorac Cardiovasc Surg; 1981 Mar; 81(3):464-9. PubMed ID: 7464209
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Use of a new double lumen catheter within the scope of intensive care medicine].
    Schockenhoff B; Hoffmann P; Koch H
    Infusionsther Klin Ernahr; 1984 Dec; 11(6):328-30. PubMed ID: 6526496
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Blood sampling technique for measurement of plasma arginine vasopressin concentration in conscious and unrestrained rats.
    Suzuki K; Koizumi N; Hirose H; Hokao R; Takemura N; Motoyoshi S
    Lab Anim Sci; 1997 Apr; 47(2):190-3. PubMed ID: 9150500
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Polyurethane II catheter as long-indwelling intravenous catheter in patients with cancer.
    Volkow P; Vázquez C; Téllez O; Aguilar C; Barrera L; Rodrgíuez E; Vilar-Compte D; Zinser J; Calderón E; Pérez-Padilla JR; Mohar A
    Am J Infect Control; 2003 Nov; 31(7):392-6. PubMed ID: 14639434
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Considerations for gastrointestinal cannulation (rumen, duodenum and ileum) in sheep with a ruminal, a simple t-type and a modified t-type cannula.
    Atasoy N; Taş A
    Dtsch Tierarztl Wochenschr; 2003 Jul; 110(7):299-302. PubMed ID: 12910869
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Permanent cannulation of the hepatic portal vein in rats.
    Sable-Amplis R; Abadie D
    J Appl Physiol; 1975 Feb; 38(2):358-9. PubMed ID: 1120765
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Percutaneous cervical central venous line placement: a comparison of the internal and external jugular vein routes.
    Belani KG; Buckley JJ; Gordon JR; Castaneda W
    Anesth Analg; 1980 Jan; 59(1):40-4. PubMed ID: 6985778
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Utility of intravenous catheters for femoral arterial cannulation in infants having complicated sternal re-entry.
    Kogon B; Voss J; Villari C; Shah N; Spitzer K; Moore M; McGoldrick A; Kirshbom P; Kanter K
    J Thorac Cardiovasc Surg; 2007 Sep; 134(3):746-9. PubMed ID: 17723828
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [A new cannula for the introduction of catheters or other cannulas into the vascular system].
    Viehweger G
    Rofo; 1975 Jan; 122(1):77-9. PubMed ID: 122963
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.