These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Spontaneous rupture of nylon sutures in the cornea spontaneously (author's transl)]. Schmitt H; Doden W Klin Monbl Augenheilkd; 1977 Sep; 171(3):392-5. PubMed ID: 926642 [TBL] [Abstract][Full Text] [Related]
3. [Experiences with absorbable corneoscleral sutures in 455 cataract extractions]. Fechner PU; Mutlak S; Reinke H Klin Monbl Augenheilkd; 1971 Aug; 159(2):228-36. PubMed ID: 4938058 [No Abstract] [Full Text] [Related]
4. [Hermetic sealing of the cataract incision with intracorneal mattress sutures]. Alekseev BN; Voronin GV Vestn Oftalmol; 1998; 114(5):15-8. PubMed ID: 9865177 [TBL] [Abstract][Full Text] [Related]
5. Suture use in pediatric cataract surgery: a survey. Lavrich JB; Goldberg DS; Nelson LB Ophthalmic Surg; 1993 Aug; 24(8):554-5. PubMed ID: 8233322 [TBL] [Abstract][Full Text] [Related]
6. Should nylon corneal sutures be routinely removed? Jackson H; Bosanquet R Br J Ophthalmol; 1991 Nov; 75(11):663-4. PubMed ID: 1751460 [TBL] [Abstract][Full Text] [Related]
7. [Absorbable polydioxanone monofilament in the surgery of the anterior segment of the eye]. Desbordes JM; Hamard H; Pouliquen Y J Fr Ophtalmol; 1983; 6(12):1007-10. PubMed ID: 6425394 [TBL] [Abstract][Full Text] [Related]
8. [Experiments on suture material prolene 10-0 and vicryl 11-0 compared with nylon 10-0 in the rabbit cornea (author's transl)]. Faulborn J; Theopold H Klin Monbl Augenheilkd; 1977 Apr; 170(4):605-13. PubMed ID: 886803 [TBL] [Abstract][Full Text] [Related]
9. [A simple procedure for treatment of astigmatism after cataract surgery]. Bechetoille A; Leclair E; Jallet G; Girard E Bull Soc Ophtalmol Fr; 1984 Nov; 84(11):1269-72. PubMed ID: 6545174 [No Abstract] [Full Text] [Related]
10. [Evaluation of the functional state of the cornea following orthokeratotomy for cataract and glaucoma]. Iashinskas VP; Karetnikova TI; Kas'ianova NS; Boborykina TN Vestn Oftalmol; 1984; (1):22-5. PubMed ID: 6710736 [No Abstract] [Full Text] [Related]
11. Comment on: Comparative analysis of non-absorbable 10-0 nylon sutures with absorbable 10-0 vicryl sutures in pediatric cataract surgery. Mohan A; Sen P; Jain E Indian J Ophthalmol; 2019 Jan; 67(1):173-174. PubMed ID: 30574939 [No Abstract] [Full Text] [Related]
17. Evaluation of biofilm formation on nylon sutures removed from clinically noninfected eyes after cataract surgery. Pan JC; Lau BH; Fam HB; Ng MM J Cataract Refract Surg; 2004 Sep; 30(9):1972-6. PubMed ID: 15342064 [TBL] [Abstract][Full Text] [Related]