These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 6023865)

  • 1. Influence of hypoxia on mean circulatory pressure and cardiac output.
    Smith EE; Crowell JW
    Am J Physiol; 1967 May; 212(5):1067-9. PubMed ID: 6023865
    [No Abstract]   [Full Text] [Related]  

  • 2. Regulation of cardiac output.
    Guyton AC
    Anesthesiology; 1968; 29(2):314-26. PubMed ID: 5635884
    [No Abstract]   [Full Text] [Related]  

  • 3. An analysis of the left ventricle as a pressure and flow generator in the intact systemic circulation.
    Abel FL
    IEEE Trans Biomed Eng; 1966 Oct; 13(4):182-8. PubMed ID: 5978289
    [No Abstract]   [Full Text] [Related]  

  • 4. Point: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Magder S
    J Appl Physiol (1985); 2006 Nov; 101(5):1523-5. PubMed ID: 16825521
    [No Abstract]   [Full Text] [Related]  

  • 5. Counterpoint: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is not correct.
    Brengelmann GL
    J Appl Physiol (1985); 2006 Nov; 101(5):1525-6; discussion 1526-7. PubMed ID: 17043330
    [No Abstract]   [Full Text] [Related]  

  • 6. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Pinsky MR
    J Appl Physiol (1985); 2006 Nov; 101(5):1528. PubMed ID: 16931559
    [No Abstract]   [Full Text] [Related]  

  • 7. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Magder S
    J Appl Physiol (1985); 2006 Nov; 101(5):1533. PubMed ID: 16931558
    [No Abstract]   [Full Text] [Related]  

  • 8. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Brengelmann GL
    J Appl Physiol (1985); 2006 Nov; 101(5):1532. PubMed ID: 17043333
    [No Abstract]   [Full Text] [Related]  

  • 9. Distribution of cardiac output in dogs.
    Pinakatt T; Richardson AW
    Am J Physiol; 1967 Oct; 213(4):905-9. PubMed ID: 6051188
    [No Abstract]   [Full Text] [Related]  

  • 10. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Baker RD
    J Appl Physiol (1985); 2006 Nov; 101(5):1529. PubMed ID: 17094184
    [No Abstract]   [Full Text] [Related]  

  • 11. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Rothe C
    J Appl Physiol (1985); 2006 Nov; 101(5):1529. PubMed ID: 17094185
    [No Abstract]   [Full Text] [Related]  

  • 12. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Mitzner W
    J Appl Physiol (1985); 2006 Nov; 101(5):1529-30. PubMed ID: 17094188
    [No Abstract]   [Full Text] [Related]  

  • 13. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Permutt S
    J Appl Physiol (1985); 2006 Nov; 101(5):1528. PubMed ID: 17094182
    [No Abstract]   [Full Text] [Related]  

  • 14. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Wang LY; Wang WK
    J Appl Physiol (1985); 2006 Nov; 101(5):1528-9. PubMed ID: 17094183
    [No Abstract]   [Full Text] [Related]  

  • 15. [Effect of different regimes of the artificial respiration on systemic hemodynamics].
    Samoĭlenko AV; Iurov AIu
    Ross Fiziol Zh Im I M Sechenova; 1998; 84(1-2):45-53. PubMed ID: 9612856
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of periodic obstructive apneas on venous return in closed-chest dogs.
    Tarasiuk A; Scharf SM
    Am Rev Respir Dis; 1993 Aug; 148(2):323-9. PubMed ID: 8342894
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cardiac preload and venous return in swimming sea bass (Dicentrarchus labrax L.).
    Sandblom E; Farrell AP; Altimiras J; Axelsson M; Claireaux G
    J Exp Biol; 2005 May; 208(Pt 10):1927-35. PubMed ID: 15879073
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of different stimulation frequencies on the cardiac output at rest and during moderate exercise in dogs with chronic atrioventricular heart block.
    Brutsaert D
    Acta Cardiol; 1965; 20(6):469-78. PubMed ID: 5295289
    [No Abstract]   [Full Text] [Related]  

  • 19. Circulatory dynamics of paired pacing in hypovolemic and cardiogenic shock.
    Goetz RH; Jallah EM; Goetz VM
    Am Heart J; 1967 Apr; 73(4):506-15. PubMed ID: 6020614
    [No Abstract]   [Full Text] [Related]  

  • 20. Central circulatory responses to work in dry heat before and after acclimatization.
    Rowell LB; Kraning KK; Kennedy JW; Evans TO
    J Appl Physiol; 1967 Mar; 22(3):509-18. PubMed ID: 6020236
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.