These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
82 related articles for article (PubMed ID: 6046781)
21. [Determination of ionized calcium in the circulating blood with a liquid membrane electrode]. Sachs C; Bourdeau A J Physiol (Paris); 1970; 62 Suppl 2(2):313-4. PubMed ID: 4953043 [No Abstract] [Full Text] [Related]
22. Errors arising in the determination of serum haptoglobins by gel filtration. Hallowes KH J Med Lab Technol; 1970 Jan; 27(1):102-8. PubMed ID: 5412550 [No Abstract] [Full Text] [Related]
23. [Automated method for determining calcium in biological liquids]. Duchassaing D; Ekindjian OG; Leluan G Ann Biol Clin (Paris); 1977; 35(2):133-8. PubMed ID: 921011 [TBL] [Abstract][Full Text] [Related]
24. Studies on the use of Coulter Chemistry in the veterinary laboratory: day-to day reproducibility and the effects of storage, hemolysis, lipemia, hyperbilirubinemia and anticoagulants on test results. Tasker JB Cornell Vet; 1978 Oct; 68(4):480-505. PubMed ID: 101346 [TBL] [Abstract][Full Text] [Related]
25. [Further notes on lipids in icteric sera with bilirubin extractable in ether]. COGNETTI S; LA PESA M Boll Soc Ital Biol Sper; 1959 Mar; 35(6):299-301. PubMed ID: 13651468 [No Abstract] [Full Text] [Related]
26. "TRUE" CREATININE CHROMOGEN DETERMINATION IN SERUM AND URINE BY SEMI-AUTOMATED ANALYSIS. POLAR E; METCOFF J Clin Chem; 1965 Aug; 11():763-70. PubMed ID: 14319232 [No Abstract] [Full Text] [Related]
27. Some aspects of bilirubin determination in the newborn using dimethyl sulfoxide. Baginski ES; Epstein E; Zak B Ann Clin Lab Sci; 1980; 10(6):486-92. PubMed ID: 7447390 [TBL] [Abstract][Full Text] [Related]
28. [Determination of calcium, sodium, potassium and magnesium in human blood sera by atomic absorption]. Szívós K; Pungor E Acta Pharm Hung; 1974 Nov; 44(6):253-61. PubMed ID: 4215286 [No Abstract] [Full Text] [Related]
29. Hemolysis interference in measuring fish plasma biochemical indicators. Mirghaed AT; Ghelichpour M; Hoseini SM; Amini K Fish Physiol Biochem; 2017 Aug; 43(4):1143-1151. PubMed ID: 28293862 [TBL] [Abstract][Full Text] [Related]
30. Toward an artificial liver. II. Removal of cholephilic anions from dogs with biliary obstruction, by hemoperfusion through charged and uncharged resins. Willson RA; Hofmann AF; Kuster GG Gastroenterology; 1974 Jan; 66(1):95-107. PubMed ID: 4809506 [No Abstract] [Full Text] [Related]
31. Arsenazo III: an improvement of the routine calcium determination in serum. Janssen JW; Helbing AR Eur J Clin Chem Clin Biochem; 1991 Mar; 29(3):197-201. PubMed ID: 2070016 [TBL] [Abstract][Full Text] [Related]
32. [Rapid diazo method for the determination of total bilirubin with a combined reagent]. Hillmann G; Beyer G Z Klin Chem Klin Biochem; 1967 Mar; 5(2):92-3. PubMed ID: 5609909 [No Abstract] [Full Text] [Related]
33. Improved total bilirubin method for the Olympus AU 5000 that decreases interferences by hemolysis or azotemia. Scott MG; Lau BW; Koenig JW; Walton KG; Hinds BJ; Ladenson JH Clin Chem; 1988 Sep; 34(9):1921. PubMed ID: 3416457 [No Abstract] [Full Text] [Related]
34. Correlation between free bilirubin and indirect bilirubin in normal newborn infants with non-hemolytic jaundice and effect of hemolysis on free bilirubin measurement by the peroxidase method. de Carvalho WB; Kopelman BI; de Araújo PS Rev Paul Med; 1992; 110(3):138-44. PubMed ID: 1341000 [TBL] [Abstract][Full Text] [Related]
35. [A fast determination of serum bilirubin with the interference from hemolysis and turbidity by three wavelength spectrophotometry]. Chai H; Dong YH Hua Xi Yi Ke Da Xue Xue Bao; 1989 Jun; 20(2):223-5. PubMed ID: 2591941 [TBL] [Abstract][Full Text] [Related]
36. Chemical correction of stored bank blood by ion exchange resin mixtures. Juggi JS; Singh ID; Chaudhry NC Indian J Physiol Pharmacol; 1973; 17(4):323-33. PubMed ID: 4802427 [No Abstract] [Full Text] [Related]