  • 1. Failure of endocardial pacemaker due to late myocardial perforation. Successful restoration of cardiac pacing by conversion to an epicardial system.
    Anielson GK; Shabetai R; Bryant LR
    J Thorac Cardiovasc Surg; 1967 Jul; 54(1):42-8. PubMed ID: 6067511
    [No Abstract]   [Full Text] [Related]  

  • 2. [Perforation of the endocardium by intracardial pacemaker with intramural wandering].
    Witte J; Vogel I
    Zentralbl Chir; 1968 Nov; 93(46):1615-8. PubMed ID: 5710883
    [No Abstract]   [Full Text] [Related]  

  • 3. [Late perforation of the right ventricle by displacement of pacemaker electrodes (report of 2 cases)].
    Ramírez Isunza JM; Argüelles Mier MA; Esparza González JJ
    Arch Inst Cardiol Mex; 1982; 52(2):129-33. PubMed ID: 7103601
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Perforation of the myocardium by an electrode as a complication of endocardial electric stimulation of the heart].
    Vul'f VN; Nazarenko EA; Liventsev VV
    Vestn Khir Im I I Grek; 1985 Nov; 135(11):135-7. PubMed ID: 4095857
    [No Abstract]   [Full Text] [Related]  

  • 5. Myocardial perforation from a permanent endocardial electrode.
    Meckstroth CV; Schoenfeld CD; Wardwell GA
    J Thorac Cardiovasc Surg; 1967 Jul; 54(1):16-21. PubMed ID: 6027854
    [No Abstract]   [Full Text] [Related]  

  • 6. [A case of "late" perforation of the right atrium during permanent endocardiac stimulation].
    Klugmann S; Pivotti F; Slavich G; Zingone B
    Minerva Med; 1978 Jul; 69(36):2459-63. PubMed ID: 683598
    [No Abstract]   [Full Text] [Related]  

  • 7. Recurrent perforation of heart by transvenous pacemaker.
    Patton RD; Lau SH; Helfant RH; Berkowitz WD; Martinez V; Stein E
    N Y State J Med; 1969 Dec; 69(23):3047-9. PubMed ID: 5260130
    [No Abstract]   [Full Text] [Related]  

  • 8. Equivalent performance of epicardial versus endocardial permanent pacing in children: a single institution and manufacturer experience.
    Odim J; Suckow B; Saedi B; Laks H; Shannon K
    Ann Thorac Surg; 2008 Apr; 85(4):1412-6. PubMed ID: 18355537
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pericardial tamponade due to perforation with a permanent endocardial pacing catheter.
    Bassan MM; Merin G
    J Thorac Cardiovasc Surg; 1977 Jul; 74(1):51-4. PubMed ID: 875442
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Complication of endocardial stimulation: perforation of the right ventricle. Clinical and electrocardiographic aspects].
    Pistolese M; de Bellis F; Catalano V; Morabito A; Cittadini A; Richichi G; Staibano M
    Boll Soc Ital Cardiol; 1973; 18(10):980-4. PubMed ID: 4807034
    [No Abstract]   [Full Text] [Related]  

  • 11. [On the diagnosis and treatment of perforation of the cardiac wall in the course of permanent electrostimulation].
    Logi G; Baldari G; Rossi M; De Bellis F
    Acta Anaesthesiol; 1969; 20():Suppl 2:181-7. PubMed ID: 5408898
    [No Abstract]   [Full Text] [Related]  

  • 12. [Treatment with artificial pacemakers from the surgical viewpoint].
    Schaudig A
    Med Klin; 1969 Apr; 64(15):674-8. PubMed ID: 5783029
    [No Abstract]   [Full Text] [Related]  

  • 13. Myocardial perforation by flexible Elema endocardial pacing catheters.
    Hurwitz BJ; Zion MM; Obel IW
    Thorax; 1974 Nov; 29(6):678-84. PubMed ID: 4450177
    [No Abstract]   [Full Text] [Related]  

  • 14. [Proceedings: Right ventricle perforation and myocardial electrode detachment caused by both endocardial and epicardial pacing].
    Nakamura A; Hara T; Nakamichi S; Makita T; Oga K
    Jpn Circ J; 1975 Jul; 39(7):848-9. PubMed ID: 1159982
    [No Abstract]   [Full Text] [Related]  

  • 15. [Intracardiac pacemaker. Perforation caused by electrolytic chemical necrosis of the ventricle].
    Actis Dato A; Campiglio P; Panero GB; Zanda S
    Minerva Med; 1974 Nov; 65(85):4429-33. PubMed ID: 4437787
    [No Abstract]   [Full Text] [Related]  

  • 16. Late perforation of the heart, pericardium, and diaphragm by an active-fixation ventricular lead.
    Akyol A; Aydin A; Erdinler I; Oguz E
    Pacing Clin Electrophysiol; 2005 Apr; 28(4):350-1. PubMed ID: 15826277
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Longstanding cardiac perforation by a permanent endocardial pacing electrode.
    Hurwitz BJ; Obel IW
    Chest; 1973 Sep; 64(3):366-8. PubMed ID: 4749389
    [No Abstract]   [Full Text] [Related]  

  • 18. [Perforation of the myocardium and hemopericardium during electric treatment of atrio-ventricular block by intracavitary stimulation].
    Fabris F; Zangrando O; Vincenzi M; Fontanin O; Dall'Antonia F
    Acta Chir Ital; 1965; 21(6):899-905. PubMed ID: 5883827
    [No Abstract]   [Full Text] [Related]  

  • 19. Pacemaker treatment. IV. Epicardial and endocardial electrode systems in permanent pacemaker treatment.
    Haghfelt T; Hansen JF; Leth A; Meibom J
    Dan Med Bull; 1974 Jun; 21(4):145-50. PubMed ID: 4853522
    [No Abstract]   [Full Text] [Related]  

  • 20. "The attack of the 52 cm lead": an unusual case of late cardiac perforation by a passive-fixation permanent pacemaker lead.
    Ramirez MF; Ching CK; Ho KL; Teo WS
    Int J Cardiol; 2007 Jan; 115(1):e5-7. PubMed ID: 16901560
    [TBL] [Abstract][Full Text] [Related]  