These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 608880)

  • 1. Capillary membranes for hemofiltration.
    Mylius UV; Streicher E; Schneider HW
    J Dial; 1977; 1(7):715-26. PubMed ID: 608880
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Asymmetric polyamide hollow-fiber filters in the hemofiltration system.
    Streicher E; Schneider H
    J Dial; 1977; 1(7):727-36. PubMed ID: 608881
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cytokine filtration and adsorption during pre- and postdilution hemofiltration in four different membranes.
    Bouman CS; van Olden RW; Stoutenbeek CP
    Blood Purif; 1998; 16(5):261-8. PubMed ID: 9917534
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Theoretical comparison of filtration by the renal glomerulus and artificial membranes.
    Tsuji M; Sakai K
    ASAIO J; 1999; 45(1):98-103. PubMed ID: 9952017
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Membranes for hemofiltration].
    Takesawa S
    Nihon Rinsho; 1991 Dec; 49 Suppl():401-5. PubMed ID: 1808290
    [No Abstract]   [Full Text] [Related]  

  • 6. Clinical observations of the polyamide hollow-fiber hemofilter in hemofiltratin systems.
    Schneider H; Streicher E
    J Dial; 1977; 1(7):737-44. PubMed ID: 608882
    [No Abstract]   [Full Text] [Related]  

  • 7. The measurement of blood density to investigate protein deposition at the blood/hollow fiber membrane interface during ultrafiltration.
    Dörp E; Schneditz D; Moser M
    Int J Artif Organs; 1991 Jul; 14(7):424-9. PubMed ID: 1889896
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biocompatibility of the polyamide membranes.
    Deppisch R; Betz M; Hänsch GM; Rauterberg EW; Ritz E
    Contrib Nephrol; 1992; 96():26-46. PubMed ID: 1740049
    [No Abstract]   [Full Text] [Related]  

  • 9. Continuous hemofiltration with polyethersulfone membranes evaluated by tele-monitoring.
    Pacitti A; Cantaluppi V; Fenoglio R; De Nitti C; Tetta C
    Contrib Nephrol; 2003; (138):126-43. PubMed ID: 12463155
    [No Abstract]   [Full Text] [Related]  

  • 10. High flux hemofiltration.
    Bosch JP; Geronemus R; Glabman S; Lysaght M; Kahn T; von Albertini B
    Artif Organs; 1978 Nov; 2(4):339-42. PubMed ID: 743001
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modified polycarbonate membranes for hemodialysis.
    Fisher BS; Higley WS; Cantor PA; Stone W
    Trans Am Soc Artif Intern Organs; 1973; 19():429-34. PubMed ID: 4737351
    [No Abstract]   [Full Text] [Related]  

  • 12. [Capillary membranes for blood diafiltration (author's transl)].
    von Mylius U; Streicher E
    Biomed Tech (Berl); 1976 Dec; 21(10):306-11. PubMed ID: 1000015
    [No Abstract]   [Full Text] [Related]  

  • 13. [Preparation of infusions for peritoneal dialysis and of hemodialysis membranes for artificial kidneys].
    Yalçindağ ON; Onur EE
    Turk Hij Deney Biyol Derg; 1977; 37(1):139-45. PubMed ID: 888211
    [No Abstract]   [Full Text] [Related]  

  • 14. Development of a capillary film artificial kidney.
    Hoeltzenbein J
    Trans Am Soc Artif Intern Organs; 1972; 18(0):124-7, 134. PubMed ID: 4679864
    [No Abstract]   [Full Text] [Related]  

  • 15. [Electron-microscopy studies of capillaries of the dialyser C-DAK 4 with reference to multiple use].
    Stein G; Linss W; Völksch G
    Z Urol Nephrol; 1977 Dec; 70(12):913-18. PubMed ID: 607695
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biocompatibility evaluation of polyamide hemofiltration.
    Panichi V; Bianchi AM; Andreini B; Casarosa L; Migliori M; De Pietro S; Taccola D; Giovannini L; Palla R
    Int J Artif Organs; 1998 Jul; 21(7):408-13. PubMed ID: 9745996
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Good biocompatibility of the polyamide hemofilter.
    von Herrath D; Hüfler M; Hartenstein-Koch K; Kutschera D; Schaefer K; Dati F
    Blood Purif; 1988; 6(2):106-10. PubMed ID: 3395472
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term performance of hemofilters in continuous hemofiltration.
    Schaeffer J; Olbricht CJ; Koch KM
    Nephron; 1996; 72(2):155-8. PubMed ID: 8684519
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of hemofilters for the development of implantable artificial kidneys.
    Dörp E; Wüstenberg PW; Klinkmann H; Ivanovich P; Trekel S
    Artif Organs; 1989 Jun; 13(3):241-6. PubMed ID: 2764764
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evolution of synthetic membranes for blood purification: the case of the Polyflux family.
    Ronco C; Crepaldi C; Brendolan A; Bragantini L; d'Intini V; Inguaggiato P; Bonello M; Krause B; Deppisch R; Goehl H; Scabardi A
    Nephrol Dial Transplant; 2003 Aug; 18 Suppl 7():vii10-20; discussion vii55. PubMed ID: 12953024
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.