These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

79 related articles for article (PubMed ID: 6116109)

  • 1. Paracetamol interference with glucose analysis.
    Roddis MJ
    Lancet; 1981 Sep; 2(8247):634-5. PubMed ID: 6116109
    [No Abstract]   [Full Text] [Related]  

  • 2. Paracetamol interference in glucose measurement by YSI analyser.
    Fleetwood JA; Robinson SM
    Br Med J (Clin Res Ed); 1981 Aug; 283(6288):438-9. PubMed ID: 6790006
    [No Abstract]   [Full Text] [Related]  

  • 3. Paracetamol interference with glucose analyzer.
    Fleetwood JA; Robinson SM
    Clin Chem; 1981 Nov; 27(11):1945-6. PubMed ID: 7296854
    [No Abstract]   [Full Text] [Related]  

  • 4. Paracetamol interference with YSI glucose analyzer.
    Farrance I; Aldons J
    Clin Chem; 1981 May; 27(5):782-3. PubMed ID: 7226518
    [No Abstract]   [Full Text] [Related]  

  • 5. Paracetamol and blood-glucose analysis with the YSI Analyzer.
    Townsend JC
    Clin Chem; 1983 Dec; 29(12):2119. PubMed ID: 6640915
    [No Abstract]   [Full Text] [Related]  

  • 6. Interference with the YSI glucose analyzer: a comment from the manufacturer.
    Sostman HE
    Clin Chem; 1982 Sep; 28(9):1981-2. PubMed ID: 7127817
    [No Abstract]   [Full Text] [Related]  

  • 7. Estimation of paracetamol.
    Sullivan M; Kenny P
    Med Lab Sci; 1985 Apr; 42(2):118-23. PubMed ID: 4068923
    [No Abstract]   [Full Text] [Related]  

  • 8. Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters.
    Cartier LJ; Leclerc P; Pouliot M; Nadeau L; Turcotte G; Fruteau-de-Laclos B
    Clin Chem; 1998 Apr; 44(4):893-4. PubMed ID: 9554511
    [No Abstract]   [Full Text] [Related]  

  • 9. Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study.
    Basu A; Veettil S; Dyer R; Peyser T; Basu R
    Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S243-7. PubMed ID: 26784129
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of paracetamol on uric acid determination.
    Wilding P; Heath DA
    Ann Clin Biochem; 1975 Jul; 12(4):142-4. PubMed ID: 15637909
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enzymic method for acetaminophen adapted to an Abbott ABA-200 analyzer.
    Higgins T
    Clin Chem; 1987 Apr; 33(4):612. PubMed ID: 3829401
    [No Abstract]   [Full Text] [Related]  

  • 12. Adaptation of an enzymatic kit for acetaminophen (paracetamol) to the Technicon RA-1000.
    Jefferson SG
    Clin Chem; 1986 Nov; 32(11):2101-2. PubMed ID: 3779957
    [No Abstract]   [Full Text] [Related]  

  • 13. Paracetamol interference with blood glucose analysis: a potentially fatal phenomenon.
    Farah DA; Boag D; Moran F; McIntosh S
    Br Med J (Clin Res Ed); 1982 Jul; 285(6336):172. PubMed ID: 6807395
    [No Abstract]   [Full Text] [Related]  

  • 14. The determination of blood spot glucose concentration using a rapid kinetic assay.
    Gamlen TR; James HC; Batstone GF
    Scand J Clin Lab Invest; 1982 Dec; 42(8):643-5. PubMed ID: 7167732
    [No Abstract]   [Full Text] [Related]  

  • 15. [Studies on glucose levels obtained on the AutoAnalyzer I (Hoffman) and critical levels of glucose tolerance tests (author's transl)].
    Arao M; Matsumiya K
    Rinsho Byori; 1976; 24(11):905-7. PubMed ID: 796499
    [No Abstract]   [Full Text] [Related]  

  • 16. Haemodialysis in paracetamol self-poisoning.
    Farid NR; Glynn JP; Kerr DN
    Lancet; 1972 Aug; 2(7774):396-8. PubMed ID: 4115220
    [No Abstract]   [Full Text] [Related]  

  • 17. Electrochemical interferences with the YSI glucose analyzer.
    Lindh M; Lindgren K; Carlström A; Masson P
    Clin Chem; 1982 Apr; 28(4 Pt 1):726. PubMed ID: 7074857
    [No Abstract]   [Full Text] [Related]  

  • 18. [Simultaneous determination of glucose and urea in whole blood, by means of the autoanalyzer I: a useful modification of the original technic].
    Caravaglios R
    Quad Sclavo Diagn; 1974 Sep; 10(3):423-8. PubMed ID: 4467216
    [No Abstract]   [Full Text] [Related]  

  • 19. In-Vivo Validation of Fully Implantable Multi-Panel Devices for Remote Monitoring of Metabolism.
    Baj-Rossi C; Cavallini A; Kilinc EG; Stradolini F; Rezzonico Jost T; Proietti M; De Micheli G; Grassi F; Dehollain C; Carrara S
    IEEE Trans Biomed Circuits Syst; 2016 Oct; 10(5):955-962. PubMed ID: 28113177
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Exploration of beta-insular function with continuous determination of blood sugar and blood insulin].
    Camilla C; Cristani A; Zandomeneghi R
    Quad Sclavo Diagn; 1974 Mar; 10(1):181-8. PubMed ID: 4610625
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.