These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 6131796)

  • 41. Evaluation of two portable wax spatulas.
    Neiburger EJ
    Gen Dent; 1978; 26(2):24-6. PubMed ID: 37143
    [No Abstract]   [Full Text] [Related]  

  • 42. [Supplementary notes on WIG fine welding in the casting technic].
    Thiele T
    Zahntechnik (Berl); 1980 Apr; 21(4):145-7. PubMed ID: 6110299
    [No Abstract]   [Full Text] [Related]  

  • 43. A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.
    Jemt T; Henry P; Lindén B; Naert I; Weber H; Bergström C
    Int J Prosthodont; 2000; 13(4):282-8. PubMed ID: 11203643
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints.
    Zupancic R; Legat A; Funduk N
    J Prosthet Dent; 2006 Oct; 96(4):273-82. PubMed ID: 17052472
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Intra-oral welding of implants for an immediate load with overdentures.
    Hruska AR; Borelli P
    J Oral Implantol; 1993; 19(1):34-8. PubMed ID: 7902447
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Repairing an implant titanium milled framework using laser welding technology: a clinical report.
    Prasad S; Monaco EA
    J Prosthet Dent; 2009 Apr; 101(4):221-5. PubMed ID: 19328274
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Laser-welded titanium frameworks supported by implants in the edentulous maxilla: a 2-year prospective multicenter study.
    Jemt T; Bergendal B; Arvidsson K; Bergendal T; Karlsson U; Linden B; Palmqvist S; Rundcrantz T; Bergström C
    Int J Prosthodont; 1998; 11(6):551-7. PubMed ID: 10023217
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Mechanical properties of weld area soldered by lasers and structural changes in hot reaction zone].
    Wu H; Cui Y; Mu W
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2001 May; 36(3):209-11. PubMed ID: 11812345
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Development and clinical application of dental spot weld & heat-treat tri-uses device].
    Yao S; Ying K; Li Z; Shen L
    Zhongguo Yi Liao Qi Xie Za Zhi; 1999 Jul; 23(4):207-9, 238. PubMed ID: 12583063
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Influence of different tightening forces before laser welding to the implant/framework fit.
    da Silveira-Júnior CD; Neves FD; Fernandes-Neto AJ; Prado CJ; Simamoto-Júnior PC
    J Prosthodont; 2009 Jun; 18(4):337-41. PubMed ID: 19210612
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [The study on mechanical properties of laser welds of titanium in dentistry].
    Lu J; Guo T; Wang B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 1999 Mar; 34(2):120-2. PubMed ID: 11834178
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Mechanical properties of titanium connectors.
    Neo TK; Chai J; Gilbert JL; Wozniak WT; Engelman MJ
    Int J Prosthodont; 1996; 9(4):379-93. PubMed ID: 8957877
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Evaluation of welded titanium joints used with cantilevered implant-supported prostheses.
    Hart CN; Wilson PR
    J Prosthet Dent; 2006 Jul; 96(1):25-32. PubMed ID: 16872927
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Survival of different types of space maintainers.
    Baroni C; Franchini A; Rimondini L
    Pediatr Dent; 1994; 16(5):360-1. PubMed ID: 7831141
    [No Abstract]   [Full Text] [Related]  

  • 55. Osseointegration for welded and cast prostheses: presentation of two cases.
    Muratori G
    J Oral Implantol; 1996; 22(3-4):276-84. PubMed ID: 9524505
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 5-year follow-up study.
    Ortorp A; Linden B; Jemt T
    Int J Prosthodont; 1999; 12(1):65-72. PubMed ID: 10196830
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effect of heat treatment on joint properties of laser-welded Ag-Au-Cu-Pd and Co-Cr alloys.
    Watanabe I; Benson AP; Nguyen K
    J Prosthodont; 2005 Sep; 14(3):170-4. PubMed ID: 16336234
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Seating and cementation of a crown restoration in a crowded anterior mandible.
    Pract Proced Aesthet Dent; 2001; 13(1):42. PubMed ID: 11301530
    [No Abstract]   [Full Text] [Related]  

  • 59. Use of new technologies in an aesthetic restorative case.
    Gleghorn T
    Dent Today; 2000 Nov; 19(11):82-7. PubMed ID: 12524784
    [No Abstract]   [Full Text] [Related]  

  • 60. A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material--an in vitro study.
    Dua R; Nandlal B
    J Indian Soc Pedod Prev Dent; 2004 Mar; 22(1):13-6. PubMed ID: 15255439
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.