106 related articles for article (PubMed ID: 6136214)
1. [Biological properties of expanded GORE-TEX--polyfluoroethylene (PTFE) prosthesis ligament].
Bolton W; Bruchman B
Aktuelle Probl Chir Orthop; 1983; 25():76-82. PubMed ID: 6136214
[No Abstract] [Full Text] [Related]
2. [Animal experimental studies on the comparison of various alloplastic materials for ligament replacement].
Claes L; Burri C; Neugebauer R; Piehler J; Mohr W
Aktuelle Probl Chir Orthop; 1983; 25():109-15. PubMed ID: 6136195
[No Abstract] [Full Text] [Related]
3. [Alloplastic ligament replacement in animal experiments].
Contzen M
Aktuelle Probl Chir Orthop; 1983; 25():66-9. PubMed ID: 6136211
[No Abstract] [Full Text] [Related]
4. [Reaction of tissues to carbon fibers as ligament prostheses of the sheep knee].
Neugebauer R; Claes L
Aktuelle Probl Chir Orthop; 1983; 25():103-8. PubMed ID: 6136194
[No Abstract] [Full Text] [Related]
5. Mechanical and biological properties of the GORE-TEX expanded polytetrafluoroethylene (PTFE) prosthetic ligament.
Bolton W; Bruchman B
Aktuelle Probl Chir Orthop; 1983; 26():40-51. PubMed ID: 6136230
[TBL] [Abstract][Full Text] [Related]
6. [Mechanical properties of the stretched GORE-TEX--polytetrafluoroethylene (PTFE) prosthesis ligament].
Bolton W; Bruchman B
Aktuelle Probl Chir Orthop; 1983; 25():42-8. PubMed ID: 6136207
[No Abstract] [Full Text] [Related]
7. The GORE-TEX expanded polytetrafluoroethylene prosthetic ligament. An in vitro and in vivo evaluation.
Bolton CW; Bruchman WC
Clin Orthop Relat Res; 1985 Jun; (196):202-13. PubMed ID: 3888468
[TBL] [Abstract][Full Text] [Related]
8. [Ligament replacement with carbon fibers in the animal experiment].
Jenkins DH
Aktuelle Probl Chir Orthop; 1983; 25():98-102. PubMed ID: 6136216
[No Abstract] [Full Text] [Related]
9. [Resorbable polymer-carbon fiber compound materials--a new method of support and leading frame for joint reconstruction].
Alexander H; Weiss AB; Parsons JR
Aktuelle Probl Chir Orthop; 1983; 25():83-97. PubMed ID: 6136215
[No Abstract] [Full Text] [Related]
10. Animal experiments for comparison of various alloplastic materials in ligament replacements.
Claes L; Burri C; Neugebauer R; Piehler J; Mohr W
Aktuelle Probl Chir Orthop; 1983; 26():101-7. PubMed ID: 6136219
[No Abstract] [Full Text] [Related]
11. [Animal experimental studies on temporary intra-articular knee joint stabilization by a synthetic ligament (polyester-silicone)].
Wirth CJ
Aktuelle Probl Chir Orthop; 1983; 25():70-5. PubMed ID: 6136213
[No Abstract] [Full Text] [Related]
12. [Alloplastic replacement of the anterior cruciate ligament by a polytetrafluoroethylene ligament. Animal experiment study].
Apel R; Mommsen U; Wening V; Jungbluth KH; Arps H; Delling G
Unfallchirurgie; 1986 Dec; 12(6):291-4. PubMed ID: 3824683
[TBL] [Abstract][Full Text] [Related]
13. [Animal experiment studies of the resistance to wear of a teflon ligament prosthesis].
Trepte CT
Sportverletz Sportschaden; 1987 Jun; 1(2):81-5. PubMed ID: 3508012
[TBL] [Abstract][Full Text] [Related]
14. Reconstruction of ligaments with expanded polytetrafluoroethylene. An experimental study in rabbits.
Hanff G; Dahlin LB; Lundborg G
Scand J Plast Reconstr Surg Hand Surg; 1992; 26(1):43-9. PubMed ID: 1626229
[TBL] [Abstract][Full Text] [Related]
15. A simple repair of the ruptured anterior cruciate ligament in the dog.
Trace CG
J S Afr Vet Assoc; 1982 Dec; 53(4):271-3. PubMed ID: 7182504
[No Abstract] [Full Text] [Related]
16. The challenge of prosthetic cruciate ligament replacement.
Tremblay GR; Laurin CA; Drovin G
Clin Orthop Relat Res; 1980; (147):88-92. PubMed ID: 7371322
[TBL] [Abstract][Full Text] [Related]
17. Mechanical properties of ligament replacement with carbon fibres.
Claes L; Neugebauer R
Aktuelle Probl Chir Orthop; 1983; 26():58-62. PubMed ID: 6136232
[TBL] [Abstract][Full Text] [Related]
18. [Evaluation of the usefulness of polytetrafluoroethylene (PTFE) prosthesis in cranioplasty. Experimental studies].
Zaborski G; Szot W
Polim Med; 1987; 17(3-4):117-22. PubMed ID: 3452815
[TBL] [Abstract][Full Text] [Related]
19. [Biological studies of Gore-Tex vascular prostheses].
Staniszewska-Kuś J
Polim Med; 1985; 15(3-4):89-97. PubMed ID: 3835547
[TBL] [Abstract][Full Text] [Related]
20. Use of GORE-TEX (polytetrafluoroethylene) in the anophthalmic socket.
Morax S
Adv Ophthalmic Plast Reconstr Surg; 1990; 8():82-7. PubMed ID: 2248727
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]