These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 6178827)

  • 121. A rapid method for immune complex detection: peg insolubilization combined with laser nephelometry.
    Schultz-Ellison G; Charland C; Driscoll J; Thayer W
    J Immunol Methods; 1979; 31(1-2):31-40. PubMed ID: 512375
    [No Abstract]   [Full Text] [Related]  

  • 122. Preparation of polyethylene glycol-modified streptokinase with disappearance of binding ability towards anti-serum and retention of activity.
    Koide A; Suzuki S; Kobayashi S
    FEBS Lett; 1982 Jun; 143(1):73-6. PubMed ID: 6180928
    [No Abstract]   [Full Text] [Related]  

  • 123. [Comments on the methodology of the PEG-IKEM test for the determination of circulating immunocomplexes].
    Vancurová M; Marecek D; Chýlková V; Procházková J; Zaydler K
    Cas Lek Cesk; 1983 Jun; 122(25):787-8. PubMed ID: 6871964
    [No Abstract]   [Full Text] [Related]  

  • 124. [A method of rapid determination of cholesterol in immune complexes].
    Shoibonov BB; Baronets VY; Panchenko LF; Kubatiev AA
    Patol Fiziol Eksp Ter; 2013; (4):109-14. PubMed ID: 24640783
    [TBL] [Abstract][Full Text] [Related]  

  • 125. [Circulating immunocomplexes. I. The effect of working conditions on the resulting values of the PEG-IKEM test. Methodology study].
    Vancurová M; Procházková J; Chýlková V; Kubíková K
    Cesk Epidemiol Mikrobiol Imunol; 1984 Mar; 33(2):116-21. PubMed ID: 6232008
    [No Abstract]   [Full Text] [Related]  

  • 126. [Assay for detecting immune complex].
    Kobayashi K; Tamai S
    Nihon Rinsho; 1999 Nov; 57 Suppl():85-9. PubMed ID: 10635782
    [No Abstract]   [Full Text] [Related]  

  • 127. Increased immunogenicity of some native antigenic determinants in a chemically changed human albumin.
    Fiume L; Busi C; Mattioli A; Spinosa G
    Naturwissenschaften; 1987 Dec; 74(12):595-6. PubMed ID: 2450284
    [No Abstract]   [Full Text] [Related]  

  • 128. Evaluation of circulating immune complexes in lymphomas and leukemias using two different assays.
    Patel GV; Gopal R; Nadkarni JJ
    Cancer Immunol Immunother; 1985; 20(1):80-4. PubMed ID: 3877562
    [TBL] [Abstract][Full Text] [Related]  

  • 129. Circulating immune complexes and rheumatoid arthritis: the induction of immune complex formation between rheumatoid factor and IgG by polyethylene glycol.
    Faaber P; van den Bersselaar LA; van de Putte L; van den Berg WB
    J Rheumatol; 1989 Oct; 16(10):1304-9. PubMed ID: 2681758
    [TBL] [Abstract][Full Text] [Related]  

  • 130. Identification of material with paternal HLA antigen immunoreactivity from purported circulating immune complexes in patients with gestational trophoblastic neoplasia.
    Lahey SJ; Steele G; Berkowitz R; Rodrick ML; Ross DS; Goldstein DP; Zamcheck N; Wilson RE; Deasy JM
    J Natl Cancer Inst; 1984 May; 72(5):983-90. PubMed ID: 6325794
    [TBL] [Abstract][Full Text] [Related]  

  • 131. Detection of immune complexes by a new assay, the polyethylene glycol precipitation-complement consumption test (PEG-CC).
    Harkiss GD; Brown DL
    Clin Exp Immunol; 1979 Apr; 36(1):117-29. PubMed ID: 111880
    [TBL] [Abstract][Full Text] [Related]  

  • 132. Detection and quantitation of immune complexes by polyethylene glycol-laser nephelometer assay. I. Immunological study in chronic serum sickness in rabbits.
    Mikulska B; Krajewski S; Madaliński K
    Arch Immunol Ther Exp (Warsz); 1983; 31(2):109-20. PubMed ID: 6418113
    [TBL] [Abstract][Full Text] [Related]  

  • 133. An evaluation of two antigen nonspecific assays for circulating immune complexes using a model system.
    Rodrick M; Rayner A; Steele G; Harte P; Finn D; Verhave M; Munroe A; Zamcheck N; Wilson R
    J Clin Lab Immunol; 1982 Apr; 7(3):193-8. PubMed ID: 6178827
    [TBL] [Abstract][Full Text] [Related]  

  • 134. [Polyethylene glycol complement consumption test (PEG-CC)].
    Ezaki I
    Nihon Rinsho; 1999 Nov; 57 Suppl():101-3. PubMed ID: 10635787
    [No Abstract]   [Full Text] [Related]  

  • 135.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 136.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 137.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 138.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 139.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 140.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]     [New Search]
    of 7.