These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 6178906)

  • 1. The correlation of lung structure with function.
    Berend N
    Lung; 1982; 160(3):115-30. PubMed ID: 6178906
    [No Abstract]   [Full Text] [Related]  

  • 2. Exponential description of the static pressure-volume curve of normal and diseased lungs.
    Gibson GJ; Pride NB; Davis J; Schroter RC
    Am Rev Respir Dis; 1979 Oct; 120(4):799-811. PubMed ID: 315738
    [No Abstract]   [Full Text] [Related]  

  • 3. The influence of lung volume on expiratory flow rates in diffuse interstitial lung disease.
    Jayamanne DS; Epstein H; Goldring RM
    Am J Med Sci; 1978; 275(3):329-36. PubMed ID: 686040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulmonary physiology.
    Fernandez E; Cherniack RM
    Adv Psychosom Med; 1985; 14():149-68. PubMed ID: 4072806
    [No Abstract]   [Full Text] [Related]  

  • 5. Volume adjustment of maximal expiratory flow rates of flow-volume loops.
    Umut S; Gemicioğlu B; Yildirim N
    Chest; 1992 Nov; 102(5):1636-7. PubMed ID: 1424923
    [No Abstract]   [Full Text] [Related]  

  • 6. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Cohen JC; Hudak J
    J Appl Physiol (1985); 2007 Nov; 103(5):1905-8; author reply 1909-10. PubMed ID: 17965243
    [No Abstract]   [Full Text] [Related]  

  • 7. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Kaczka DW
    J Appl Physiol (1985); 2007 Nov; 103(5):1907; author reply 1909-10. PubMed ID: 18098391
    [No Abstract]   [Full Text] [Related]  

  • 8. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Zeldin D; Card JW; Carey MA; Voltz JW
    J Appl Physiol (1985); 2007 Nov; 103(5):1906; author reply 1909-10. PubMed ID: 18098389
    [No Abstract]   [Full Text] [Related]  

  • 9. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Lundblad LK
    J Appl Physiol (1985); 2007 Nov; 103(5):1907-8; author reply 1909-10. PubMed ID: 18098392
    [No Abstract]   [Full Text] [Related]  

  • 10. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Suki B
    J Appl Physiol (1985); 2007 Nov; 103(5):1906-7; author reply 1909-10. PubMed ID: 18098390
    [No Abstract]   [Full Text] [Related]  

  • 11. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Hantos Z
    J Appl Physiol (1985); 2007 Nov; 103(5):1905-6; author reply 1909-10. PubMed ID: 18098388
    [No Abstract]   [Full Text] [Related]  

  • 12. "Lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease".
    Fredberg JJ
    J Appl Physiol (1985); 2007 Nov; 103(5):1905; author reply 1909-10. PubMed ID: 18098386
    [No Abstract]   [Full Text] [Related]  

  • 13. Counterpoint: lung impedance measurements are not more useful than simpler measurements of lung function in animal models of pulmonary disease.
    Mitzner W
    J Appl Physiol (1985); 2007 Nov; 103(5):1901-3; discussion 1903-4. PubMed ID: 17965240
    [No Abstract]   [Full Text] [Related]  

  • 14. Density dependence of maximal expiratory flow in chronic obstructive pulmonary disease.
    Meadows JA; Rodarte JR; Hyatt RE
    Am Rev Respir Dis; 1980 Jan; 121(1):47-53. PubMed ID: 7352713
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Point:Counterpoint: lung impedance measurements are/are not more useful than simpler measurements of lung function in animal models of pulmonary disease.
    Bates JH
    J Appl Physiol (1985); 2007 Nov; 103(5):1900-1; discussion 1904. PubMed ID: 17431089
    [No Abstract]   [Full Text] [Related]  

  • 16. Flow-volume curve contour in COPD: correlation with pulmonary mechanics.
    Jayamanne DS; Epstein H; Goldring RM
    Chest; 1980 Jun; 77(6):749-57. PubMed ID: 7398386
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lung function in interstitial lung diseases in children.
    Gaultier C; Chaussain M; Boulé M; Buvry A; Allaire Y; Perret L; Girard F
    Bull Eur Physiopathol Respir; 1980; 16(1):57-66. PubMed ID: 7357127
    [No Abstract]   [Full Text] [Related]  

  • 18. Pulmonary mechanics during early postnatal years.
    Motoyama EK
    Pediatr Res; 1977 Mar; 11(3 Pt 2):220-3. PubMed ID: 846772
    [No Abstract]   [Full Text] [Related]  

  • 19. [Regional distribution of TLC, VC and RV in obturative and restrictive pulmonary diseases (author's transl)].
    Tarkowska A; Zaorska-Rajca J; Wojtowicz A; Szarewicz-Adamczyk W
    Pol Przegl Radiol Med Nukl; 1979; 43(5):269-70. PubMed ID: 542393
    [No Abstract]   [Full Text] [Related]  

  • 20. Clinical Utility of Additional Measurement of Total Lung Capacity in Diagnosing Obstructive Lung Disease in Subjects With Restrictive Pattern of Spirometry.
    Lee H; Chang B; Kim K; Song WJ; Chon HR; Kang HK; Kim JS; Jeong BH; Oh YM; Koh WJ; Park HY
    Respir Care; 2016 Apr; 61(4):475-82. PubMed ID: 26884447
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.