168 related articles for article (PubMed ID: 6179050)
1. Pulse width dependent increase in the pacemaker automatic interval. Ohm OJ; Breivik K; Hammer E Pacing Clin Electrophysiol; 1982 May; 5(3):329-40. PubMed ID: 6179050 [TBL] [Abstract][Full Text] [Related]
2. Usefulness of transcutaneous triggering of conventional implanted pulse generators by an activity-sensing pacemaker for predicting effectiveness of rate response pacing. Fetter J; Benditt DG; Mianulli M Am J Cardiol; 1988 Nov; 62(13):901-5. PubMed ID: 3177238 [TBL] [Abstract][Full Text] [Related]
3. Acute and chronic pulse-width thresholds in solid versus porous tip electrodes. Breivik K; Ohm OJ; Engedal H Pacing Clin Electrophysiol; 1982 Sep; 5(5):650-7. PubMed ID: 6182535 [TBL] [Abstract][Full Text] [Related]
4. A randomized study on the effects of pacemaker programming to a lower output on projected pulse generator longevity. Schuchert A; Meinertz T; Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1234-9. PubMed ID: 11523609 [TBL] [Abstract][Full Text] [Related]
5. Characterization of pacemaker arrhythmias due to normally functioning AV demand (DVI) pulse generators. Barold SS; Falkoff MD; Ong LS; Heinle RA Pacing Clin Electrophysiol; 1980 Nov; 3(6):712-23. PubMed ID: 6161354 [TBL] [Abstract][Full Text] [Related]
6. [Prerequisites for pacemaker electrodes for individual programming of a low stimulation impulse (comparison of an Elgiloy and a steroid-dependent pacemaker electrode)]. Schuchert A; Kuck KH; Bleifeld W Z Kardiol; 1990 Jun; 79(6):403-7. PubMed ID: 2378158 [TBL] [Abstract][Full Text] [Related]
7. The interdependence between electrogram, total electrode impedance and pacemaker input impedance necessary to obtain adequate functioning of demand pacemakers. Ohm OJ Pacing Clin Electrophysiol; 1979 Jul; 2(4):465-85. PubMed ID: 95316 [TBL] [Abstract][Full Text] [Related]
8. Inhibition of bipolar demand pacemaker by diaphragmatic myopotentials. Barold SS; Ong LS; Falkoff MD; Heinle RA Circulation; 1977 Oct; 56(4 Pt 1):679-83. PubMed ID: 902394 [TBL] [Abstract][Full Text] [Related]
9. Safety and efficiency of pulse charge multiplication for chronic ventricular output programming. Kindermann M; Kusch O; Fröhlig G; Markwirth T; Schwaab B; Schwerdt H Pacing Clin Electrophysiol; 2001 Apr; 24(4 Pt 1):430-40. PubMed ID: 11341079 [TBL] [Abstract][Full Text] [Related]
10. Clinical experience with a bradycardia indicating pacemaker. Rosenqvist M; Edhag KO; Vallin HO Pacing Clin Electrophysiol; 1983 May; 6(3 Pt 1):515-24. PubMed ID: 6191288 [TBL] [Abstract][Full Text] [Related]
11. The ventricular endocardial electrogram and pacemaker sensing. Furman S; Hurzeler P; DeCaprio V J Thorac Cardiovasc Surg; 1977 Feb; 73(2):258-66. PubMed ID: 834065 [TBL] [Abstract][Full Text] [Related]
12. Reliability of the evoked response in determining the paced ventricular rate and performance of the QT or rate responsive (TX) pacemaker. Fananapazir L; Rademaker M; Bennett DH Pacing Clin Electrophysiol; 1985 Sep; 8(5):701-14. PubMed ID: 2414752 [TBL] [Abstract][Full Text] [Related]
13. Crosstalk due to activation of atrial sense marker function of DDD pulse generators. Barold SS; Falkoff MD; Ong LS; Heinle RA; Sanders R Pacing Clin Electrophysiol; 1987 Mar; 10(2):293-301. PubMed ID: 2437533 [TBL] [Abstract][Full Text] [Related]
15. Galvanic element produced by defective electrode insulation--a possible cause of abnormal pulse generator inhibition. Levander-Lindgren M; Sylvén JC; Thorén A Scand J Thorac Cardiovasc Surg; 1983; 17(1):85-8. PubMed ID: 6867647 [TBL] [Abstract][Full Text] [Related]