These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 6195603)

  • 1. The significance of surface changes on explanted polyurethane pacemaker leads.
    Timmis GC; Westveer DC; Martin R; Gordon S
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):845-57. PubMed ID: 6195603
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thermoplastic polyurethanes as insulating materials for long-life cardiac pacing leads.
    Pande GS
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):858-67. PubMed ID: 6195604
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant experience with unipolar polyurethane pacing leads.
    Byrd CL; McArthur W; Stokes K; Sivina M; Yahr WZ; Greenberg J
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):869-82. PubMed ID: 6195605
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Degradation of explanted polyurethane cardiac pacing leads and of polyurethane.
    Chawla AS; Blais P; Hinberg I; Johnson D
    Biomater Artif Cells Artif Organs; 1988; 16(4):785-800. PubMed ID: 3219417
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implant effects on polyurethane and silicone cardiac pacing leads in humans: insulation measurements and SEM observations.
    Barbaro V; Bosi C; Caiazza S; Chistolini P; Ialongo D; Rosa P
    Biomaterials; 1985 Jan; 6(1):28-32. PubMed ID: 3971015
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Self-inhibition of an AV sequential demand (DVI) pulse generator due to polyurethane lead insulation disruption.
    Sanford CF
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):840-4. PubMed ID: 6195602
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Polyurethane leads: facts and controversy.
    Scheuer-Leeser M; Irnich W; Kreuzer J
    Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):454-63. PubMed ID: 6189092
    [TBL] [Abstract][Full Text] [Related]  

  • 8. False inhibition of an atrial demand pacemaker caused by an insulation defect in a polyurethane lead.
    van Gelder LM; El Gamal MI
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):834-9. PubMed ID: 6195601
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term comparison of the electrical characteristics of polyurethane and polyethylene insulated ventricular leads.
    Bluhm G; Larsen FF; Nordlander R; Pehrsson SK
    Pacing Clin Electrophysiol; 1990 May; 13(5):583-7. PubMed ID: 1693194
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Examination of explanted polyurethane pacemaker leads using the scanning electron microscope.
    Beyersdorf F; Kreuzer J; Schmidts L; Satter P
    Pacing Clin Electrophysiol; 1985 Jul; 8(4):562-8. PubMed ID: 2410883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biodegradation of polyether polyurethane inner insulation in bipolar pacemaker leads.
    Wiggins MJ; Wilkoff B; Anderson JM; Hiltner A
    J Biomed Mater Res; 2001 May; 58(3):302-7. PubMed ID: 11319745
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of an in-line bipolar polyurethane ventricular pacing lead.
    Sweesy MW; Forney CC; Hayes DL; Batey RL; Forney RC
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1982-5. PubMed ID: 1279584
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polyether polyurethanes for implantable pacemaker leads.
    Stokes K; Cobian K
    Biomaterials; 1982 Oct; 3(4):225-31. PubMed ID: 7171682
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-term performance of polyurethane pacing leads: mechanisms of design-related failures.
    Phillips R; Frey M; Martin RO
    Pacing Clin Electrophysiol; 1986 Nov; 9(6):1166-72. PubMed ID: 2432527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo thrombogenicity of implantable cardiac pacing leads.
    Devanathan T; Sluetz JE; Young KA
    Biomater Med Devices Artif Organs; 1980; 8(4):369-79. PubMed ID: 7272410
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ten-year experience with implanted polyurethane lead insulation.
    Stokes KB; Church T
    Pacing Clin Electrophysiol; 1986 Nov; 9(6):1160-5. PubMed ID: 2432526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Short-term extraction profile of cardiac pacing leads with hybrid silicone-polyurethane insulator: a pilot study.
    Di Cori A; Bongiorni MG; Zucchelli G; Lilli A; Coluccia G; Fabiani I; Segreti L; Paperini L; Viani S; Soldati E
    Int J Cardiol; 2013 Oct; 168(4):4432-3. PubMed ID: 23910442
    [No Abstract]   [Full Text] [Related]  

  • 18. Polyurethane leads.
    Furman S
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):833. PubMed ID: 6195600
    [No Abstract]   [Full Text] [Related]  

  • 19. Removing fresh tissue from explanted polyurethane prostheses: which approach facilitates physico-chemical analysis?
    Zhang Z; Guidoin R; King MW; How TV; Marois Y; Laroche G
    Biomaterials; 1995 Mar; 16(5):369-80. PubMed ID: 7662822
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental study about removal of the implanted tined polyurethane ventricular lead by radiofrequency waves through the lead.
    Ebe K; Funazaki T; Aizawa Y; Shibata A; Fukuda T
    Pacing Clin Electrophysiol; 1991 Aug; 14(8):1222-7. PubMed ID: 1719497
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.