115 related articles for article (PubMed ID: 619718)
1. Ear oximetry in clinical practice.
Chaudhary BA; Burki NK
Am Rev Respir Dis; 1978 Jan; 117(1):173-5. PubMed ID: 619718
[TBL] [Abstract][Full Text] [Related]
2. The accuracy of the Hewlett-Packard 47201A ear oximeter below 50% saturation.
Stradling JR
Bull Eur Physiopathol Respir; 1982; 18(5):791-4. PubMed ID: 6927531
[TBL] [Abstract][Full Text] [Related]
3. Continuous in vivo measurement of arterial oxygen saturation by oximetry.
Flick MR; Block AJ
Heart Lung; 1977; 6(6):990-3. PubMed ID: 244328
[TBL] [Abstract][Full Text] [Related]
4. Comparison of invasive and noninvasive saturation monitoring in prescribing oxygen during exercise in COPD patients.
Carone M; Patessio A; Appendini L; Purro A; Czernicka E; Zanaboni S; Donner CF
Eur Respir J; 1997 Feb; 10(2):446-51. PubMed ID: 9042647
[TBL] [Abstract][Full Text] [Related]
5. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
Ramanathan R; Durand M; Larrazabal C
Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
[TBL] [Abstract][Full Text] [Related]
6. Accuracy sensitivity to carboxyhemoglobin, and speed of response of the Hewlett-Packard 47201A ear oximeter.
Douglas NJ; Brash HM; Wraith PK; Calverley PM; Leggett RJ; McElderry L; Flenley DC
Am Rev Respir Dis; 1979 Feb; 119(2):311-3. PubMed ID: 434601
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
[TBL] [Abstract][Full Text] [Related]
8. Deriving the arterial Po
Prisk GK; West JB
J Appl Physiol (1985); 2019 Oct; 127(4):1067-1074. PubMed ID: 31436512
[TBL] [Abstract][Full Text] [Related]
9. Improved ear oximetry with a rubefacient ointment.
Schneider AJ; Miller R; Baetz WR
Crit Care Med; 1978; 6(6):384-6. PubMed ID: 720103
[TBL] [Abstract][Full Text] [Related]
10. A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter.
Decker MJ; Dickensheets D; Arnold JL; Cheung PW; Strohl KP
Biomed Instrum Technol; 1990; 24(2):122-6. PubMed ID: 2322755
[TBL] [Abstract][Full Text] [Related]
11. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.
Ries AL; Farrow JT; Clausen JL
Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542
[TBL] [Abstract][Full Text] [Related]
12. Ear oximetry during combined hypoxia and exercise.
Smyth RJ; D'Urzo AD; Slutsky AS; Galko BM; Rebuck AS
J Appl Physiol (1985); 1986 Feb; 60(2):716-9. PubMed ID: 3949671
[TBL] [Abstract][Full Text] [Related]
13. Non-invasive measurement of blood oxygen levels.
Beyerl D
Am J Med Technol; 1982 May; 48(5):355-9. PubMed ID: 7102718
[TBL] [Abstract][Full Text] [Related]
14. Quantitative 15 steps exercise oximetry as a marker of disease severity in patients with chronic obstructive pulmonary disease.
Kramer MR; Krivoruk V; Lebzelter J; Liani M; Fink G
Isr Med Assoc J; 1999 Nov; 1(3):165-8. PubMed ID: 10731326
[TBL] [Abstract][Full Text] [Related]
15. Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation.
Saunders NA; Powles AC; Rebuck AS
Am Rev Respir Dis; 1976 Jun; 113(6):745-9. PubMed ID: 937815
[TBL] [Abstract][Full Text] [Related]
16. Accuracy of oxyhemoglobin saturation monitors during simulated altitude exposure of men with chronic obstructive pulmonary disease.
Mehm WJ; Dillard TA; Berg BW; Dooley JW; Rajagopal KR
Aviat Space Environ Med; 1991 May; 62(5):418-21. PubMed ID: 2053906
[TBL] [Abstract][Full Text] [Related]
17. Comparison of three methods for determining oxygen saturation in arterial blood.
Thomas VE; Anema RJ; McNamara JJ
Am J Med Technol; 1975 Oct; 41(10):360-3. PubMed ID: 1190261
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a new method for assessing arterial oxygen pressure, avoiding arterial blood collection.
Mastropasqua B; Cavigioli G; Pelucchi A; Foresi A; Marazzini L
Am Rev Respir Dis; 1992 Feb; 145(2 Pt 1):488-90. PubMed ID: 1736762
[TBL] [Abstract][Full Text] [Related]
20. Measurement of retinal oxygen saturation in patients with chronic obstructive pulmonary disease.
Palkovits S; Lasta M; Boltz A; Schmidl D; Kaya S; Hammer M; Marzluf B; Popa-Cherecheanu A; Frantal S; Schmetterer L; Garhöfer G
Invest Ophthalmol Vis Sci; 2013 Feb; 54(2):1008-13. PubMed ID: 23307953
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]