These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 6200861)

  • 21. "Sensing alternans" in a patient with a newly implanted pacemaker.
    Makaryus AN; Boal B
    Clin Cardiol; 2006 Mar; 29(3):131-2. PubMed ID: 16596837
    [TBL] [Abstract][Full Text] [Related]  

  • 22. First derivative of right ventricular pressure, dP/dt, as a sensor for a rate adaptive VVI pacemaker: initial experience.
    Ovsyshcher I; Guetta V; Bondy C; Porath A
    Pacing Clin Electrophysiol; 1992 Feb; 15(2):211-8. PubMed ID: 1372420
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cardiac pacemaker therapy: clinical considerations.
    Castle LW
    Cardiovasc Clin; 1981; 12(2):117-25. PubMed ID: 7344768
    [No Abstract]   [Full Text] [Related]  

  • 24. Crosstalk triggered safety standby pacing associated with an improperly seated ventricular lead.
    Sun Q; Chen K; Zhang S
    Europace; 2008 Jan; 10(1):75-6. PubMed ID: 18025063
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Exploration of pacing treatment in sick sinus syndrome].
    Wang KP
    Zhonghua Xin Xue Guan Bing Za Zhi; 1992 Oct; 20(5):303-5. PubMed ID: 1306825
    [No Abstract]   [Full Text] [Related]  

  • 26. DDI pacing: indications, expectations, and follow-up.
    Irwin M; Harris L; Cameron D; Louis C; Radvanszky E; Goldman B
    Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):274-9. PubMed ID: 7513851
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pacing failure due to microdislodgement of ventricular pacing lead detected by home monitoring technology.
    Loricchio ML; Castro A; Ciolli A; Sasdelli M; Ferraiuolo G
    J Cardiovasc Med (Hagerstown); 2008 Sep; 9(9):946-8. PubMed ID: 18695437
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Sick sinus syndrome and diffuse impairment of the conduction system in a child: successful pacing with a steroid eluting endocardial pacing lead.
    Capucci A; Boriani G; Galli R; Picchio FM; Pierangeli A; Magnani B
    Pediatr Cardiol; 1992 Jan; 13(1):44-7. PubMed ID: 1736268
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Prerequisites for pacemaker electrodes for individual programming of a low stimulation impulse (comparison of an Elgiloy and a steroid-dependent pacemaker electrode)].
    Schuchert A; Kuck KH; Bleifeld W
    Z Kardiol; 1990 Jun; 79(6):403-7. PubMed ID: 2378158
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Programming of the pacing impulse in pacemakers connected to steroid lead systems.
    Schuchert A; Cappato R; Kuck KH; Meinertz T
    Pacing Clin Electrophysiol; 1995 Feb; 18(2):318-22. PubMed ID: 7731880
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Pacemaker treatment of sick sinus syndrome in children.
    Gillette PC; Shannon C; Garson A; Porter CJ; Ott D; Cooley DA; McNamara DG
    J Am Coll Cardiol; 1983 May; 1(5):1325-9. PubMed ID: 6833672
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Runaway in a modern "soft top" pacemaker.
    Betts TR; Thomas RD; Hubbard WN
    Pacing Clin Electrophysiol; 1997 Nov; 20(11):2870-1. PubMed ID: 9392822
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pacing mode selection in patients with sick sinus syndrome.
    Nielsen JC
    Dan Med Bull; 2007 Feb; 54(1):1-17. PubMed ID: 17349215
    [No Abstract]   [Full Text] [Related]  

  • 35. Efficacy of prophylactic epicardial pacing leads in children and young adults.
    Cohen MI; Rhodes LA; Spray TL; Gaynor JW
    Ann Thorac Surg; 2004 Jul; 78(1):197-202; discussion 202-3. PubMed ID: 15223427
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Anomalous "VVI" pacing of a dual chamber pacemaker when programmed in DDI(R) mode.
    Masini M; Dianda R; Cortigiani L; Nannini E
    Pacing Clin Electrophysiol; 1999 Sep; 22(9):1404-6. PubMed ID: 10527025
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Treatment of paroxysmal supraventricular tachycardia of A-V nodal re-entry mechanisms with sinus bradycardia by pacemaker implantation (author's transl)].
    Ohno T; Sugiki K; Fujiwara T; Yamagishi M; Todo K; Komatsu S
    Kyobu Geka; 1979 Aug; 32(8):610-5. PubMed ID: 480753
    [No Abstract]   [Full Text] [Related]  

  • 38. Presyncopal episodes after implantation of dual-chamber pacemaker programmed in SafeR pacing mode.
    San Antonio R; Benito EM; Tolosana JM; Emilce Trucco M; Mont L
    Europace; 2017 May; 19(5):807. PubMed ID: 28398470
    [No Abstract]   [Full Text] [Related]  

  • 39. Loss of atrial capture during DDD pacing: what is the mechanism?
    Barold SS
    Pacing Clin Electrophysiol; 1998 Oct; 21(10):1988-9. PubMed ID: 9793095
    [No Abstract]   [Full Text] [Related]  

  • 40. [Marked bradycardia during anesthetic induction treated with temporary cardiac pacing in a patient with latent sick sinus syndrome].
    Murakawa T; Ishihara H; Matsuki A
    Masui; 2001 Jan; 50(1):65-8. PubMed ID: 11211756
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.