These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
26. Steroid eluting high impedance pacing leads decrease short and long-term current drain: results from a multicenter clinical trial. CapSure Z investigators. Ellenbogen KA; Wood MA; Gilligan DM; Zmijewski M; Mans D Pacing Clin Electrophysiol; 1999 Jan; 22(1 Pt 1):39-48. PubMed ID: 9990599 [TBL] [Abstract][Full Text] [Related]
27. Survival of implantable pacemaker leads. The Implantable Lead Registry. Furman S; Benedek ZM Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1910-4. PubMed ID: 1704566 [TBL] [Abstract][Full Text] [Related]
28. Improved epimyocardial pacing: initial experience with a new bipolar, steroid-eluting, high impedance lead design. Karpawich PP; Stokes KB; Proctor K; Schallhorn R; McVenes R; Factkor M Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):2032-7. PubMed ID: 7845813 [TBL] [Abstract][Full Text] [Related]
29. Ten-year experience with implanted polyurethane lead insulation. Stokes KB; Church T Pacing Clin Electrophysiol; 1986 Nov; 9(6):1160-5. PubMed ID: 2432526 [TBL] [Abstract][Full Text] [Related]
30. Implant effects on polyurethane and silicone cardiac pacing leads in humans: insulation measurements and SEM observations. Barbaro V; Bosi C; Caiazza S; Chistolini P; Ialongo D; Rosa P Biomaterials; 1985 Jan; 6(1):28-32. PubMed ID: 3971015 [TBL] [Abstract][Full Text] [Related]
31. Degradation of explanted polyurethane cardiac pacing leads and of polyurethane. Chawla AS; Blais P; Hinberg I; Johnson D Biomater Artif Cells Artif Organs; 1988; 16(4):785-800. PubMed ID: 3219417 [TBL] [Abstract][Full Text] [Related]
33. False inhibition of an atrial demand pacemaker caused by an insulation defect in a polyurethane lead. van Gelder LM; El Gamal MI Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):834-9. PubMed ID: 6195601 [TBL] [Abstract][Full Text] [Related]
34. The significance of surface changes on explanted polyurethane pacemaker leads. Timmis GC; Westveer DC; Martin R; Gordon S Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):845-57. PubMed ID: 6195603 [TBL] [Abstract][Full Text] [Related]
35. Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results. Dodge-Khatami A; Kadner A; Dave H; Rahn M; Prêtre R; Bauersfeld U Eur J Cardiothorac Surg; 2005 Oct; 28(4):541-5. PubMed ID: 16125947 [TBL] [Abstract][Full Text] [Related]
36. A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children. Tomaske M; Gerritse B; Kretzers L; Pretre R; Dodge-Khatami A; Rahn M; Bauersfeld U Ann Thorac Surg; 2008 May; 85(5):1704-11. PubMed ID: 18442570 [TBL] [Abstract][Full Text] [Related]
37. High incidence of Pellethane 90A lead malfunction. Pachulski R; Zasadil M; Adkins D; Hanif B Europace; 2002 Jan; 4(1):45-7. PubMed ID: 11846316 [TBL] [Abstract][Full Text] [Related]