These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. [Effectiveness of the methods of electric cardiac stimulation and low-energy cardioversion-defibrillation in the prevention and treatment of ventricular tachycardia and ventricular fibrillation]. Pekarskiĭ VV; Gimrikh EO; Oferkin AI; Maslov MG; Vecherskiĭ IuIu; Popov SV; Pekarskaia MV; Porotov AV Kardiologiia; 1990 Nov; 30(11):86-90. PubMed ID: 2087041 [TBL] [Abstract][Full Text] [Related]
5. Use of electrical pacemakers in the treatment of ventricular tachycardia and ventricular fibrillation. Kerr CR; Klein GJ; Cooper JA; Sharma AD Cardiovasc Clin; 1985; 16(1):215-37. PubMed ID: 3915712 [TBL] [Abstract][Full Text] [Related]
6. Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants. Fromer M; Brachmann J; Block M; Siebels J; Hoffmann E; Almendral J; Ohm OJ; den Dulk K; Coumel P; Camm AJ Circulation; 1992 Aug; 86(2):363-74. PubMed ID: 1638705 [TBL] [Abstract][Full Text] [Related]
7. Use of electrical pacing and automatic cardioversion defibrillation for normal cardiac function recovery. Pekarsky V; Astrakhantsev Y; Belenkov Y; Gimrikh E; Oferkin A; Maslov M; Popov S; Pekarskaya M; Markov V; Vasiltsev Y Pacing Clin Electrophysiol; 1986 Nov; 9(6 Pt 2):1349-55. PubMed ID: 2432561 [TBL] [Abstract][Full Text] [Related]
8. Antitachycardia pacing and implantable cardioverter defibrillators. Furman S; Mercando AD Annu Rev Med; 1989; 40():123-36. PubMed ID: 2729924 [TBL] [Abstract][Full Text] [Related]
9. Clinical performance of the implantable cardioverter-defibrillator. Mirowski M; Reid PR; Mower MM; Watkins L; Platia EV; Griffith LS; Guarnieri T; Thomas A; Juanteguy JM Pacing Clin Electrophysiol; 1984 Nov; 7(6 Pt 2):1345-50. PubMed ID: 6209681 [TBL] [Abstract][Full Text] [Related]
10. Implantation of automatic cardioverter-defibrillators via median sternotomy. Brodman R; Fisher JD; Furman S; Johnston DR; Kim SG; Matos JA; Waspe LE Pacing Clin Electrophysiol; 1984 Nov; 7(6 Pt 2):1363-9. PubMed ID: 6209684 [TBL] [Abstract][Full Text] [Related]
11. [Combined anti-bradycardia/anti-tachycardia pacemaker-cardioverter-defibrillator systems in patients with recurrent ventricular tachyarrhythmias]. Schmitt C; Brachmann J; Saggau W; Beyer T; Waldecker B; Scharowski K; Hilbel T; Montero M; Offner B; Schöls W Z Kardiol; 1991 Nov; 80(11):665-72. PubMed ID: 1792808 [TBL] [Abstract][Full Text] [Related]
12. Electronic control of ventricular tachyarrhythmias: overview and future directions. Winkle RA Pacing Clin Electrophysiol; 1984 Nov; 7(6 Pt 2):1375-9. PubMed ID: 6209686 [TBL] [Abstract][Full Text] [Related]
13. Device therapy of ventricular tachyarrhythmias. Rosenfeld LE Cardiol Clin; 1988 Aug; 6(3):437-48. PubMed ID: 3073009 [TBL] [Abstract][Full Text] [Related]
14. Clinical transvenous cardioversion of recurrent life-threatening ventricular tachyarrhythmias: low energy synchronized cardioversion of ventricular tachycardia and termination of ventricular fibrillation in patients using a catheter electrode. Zipes DP; Jackman WM; Heger JJ; Chilson DA; Browne KF; Naccarelli GV; Rahilly GT; Prystowsky EN Am Heart J; 1982 May; 103(5):789-94. PubMed ID: 7072583 [TBL] [Abstract][Full Text] [Related]
15. Management of ventricular tachyarrhythmias. Part I. Akhtar M JAMA; 1982 Feb; 247(5):671-4. PubMed ID: 7054570 [No Abstract] [Full Text] [Related]
16. Implantable cardioverter-defibrillators (ICDs) 1989: how close are we to the ideal device? de Belder MA; Camm AJ Clin Cardiol; 1989 Jun; 12(6):339-45. PubMed ID: 2736821 [TBL] [Abstract][Full Text] [Related]
17. Experience with a new implantable pacer-, cardioverter-defibrillator for the therapy of recurrent sustained ventricular tachyarrhythmias: a step toward a universal ventricular tachyarrhythmia control device. Fromer M; Schläpfer J; Fischer A; Kappenberger L Pacing Clin Electrophysiol; 1991 Aug; 14(8):1288-98. PubMed ID: 1719507 [TBL] [Abstract][Full Text] [Related]
18. [Clinical assessment and indications for automatic defibrillation]. Jung W; Manz M; Lüderitz B Ther Umsch; 1992 Aug; 49(8):580-5. PubMed ID: 1519187 [TBL] [Abstract][Full Text] [Related]
19. Ventricular arrhythmias: medical therapy, device treatment, and indications for electrophysiologic study. Sager PT; Batsford WP Cardiol Clin; 1988 Feb; 6(1):37-47. PubMed ID: 3048673 [TBL] [Abstract][Full Text] [Related]
20. Failure of a second and third generation implantable cardioverter defibrillator to sense ventricular tachycardia: implications for fixed-gain sensing devices. Sperry RE; Ellenbogen KA; Wood MA; Stambler BS; DiMarco JP; Haines DE Pacing Clin Electrophysiol; 1992 May; 15(5):749-55. PubMed ID: 1382277 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]