BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 6220471)

  • 1. Particle sizing and biokinetics of interstitial lymphoscintigraphic agents.
    Bergqvist L; Strand SE; Persson BR
    Semin Nucl Med; 1983 Jan; 13(1):9-19. PubMed ID: 6220471
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative lymphoscintigraphy I: Basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits.
    Strand SE; Persson BR
    J Nucl Med; 1979 Oct; 20(10):1038-46. PubMed ID: 231640
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Deposition of small 99mTc-labelled colloids in bone marrow and lymph nodes.
    Nagai K; Ito Y; Otsuka N; Muranaka A
    Eur J Nucl Med; 1982; 7(2):66-70. PubMed ID: 7084270
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental studies on uptake of 99mTc-antimony sulfide colloid in RES--a comparison with various 99mTc-colloids.
    Nagai K; Ito Y; Otsuka N; Muranaka A; Kaji T; Kajihara Y
    Int J Nucl Med Biol; 1981; 8(1):85-9. PubMed ID: 7228522
    [No Abstract]   [Full Text] [Related]  

  • 5. Particle sizes of colloids to be used in sentinel lymph node radiolocalization.
    Jimenez IR; Roca M; Vega E; García ML; Benitez A; Bajén M; Martín-Comín J
    Nucl Med Commun; 2008 Feb; 29(2):166-72. PubMed ID: 18094639
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Significance of lymphoscintigraphic mapping with Tc-99m human serum albumin and tin colloid in sentinel lymph node biopsy in breast cancer.
    Kim R; Osaki A; Kojima J; Toge T
    Int J Oncol; 2001 Nov; 19(5):991-6. PubMed ID: 11604999
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Lymphoscintigraphy. Comparison of 2 microcolloids labeled with Tc99m].
    Ciambellotti E; Lanza E; Coda C; Cartia GL
    Minerva Med; 1986 Mar; 77(9-10):313-6. PubMed ID: 3951733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Filtered technetium-99m-sulfur colloid evaluated for lymphoscintigraphy.
    Hung JC; Wiseman GA; Wahner HW; Mullan BP; Taggart TR; Dunn WL
    J Nucl Med; 1995 Oct; 36(10):1895-901. PubMed ID: 7562061
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An evaluation of methods for sizing radiocolloidal particles.
    Rosenthal SN; Bardfeld PA
    Nucl Med Commun; 1986 Jul; 7(7):511-7. PubMed ID: 3774251
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Particle size analysis of (99m)Tc-labeled and unlabeled antimony trisulfide and rhenium sulfide colloids intended for lymphoscintigraphic application.
    Tsopelas C
    J Nucl Med; 2001 Mar; 42(3):460-6. PubMed ID: 11337524
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Size Control of (99m)Tc-tin Colloid Using PVP and Buffer Solution for Sentinel Lymph Node Detection.
    Kim EM; Lim ST; Sohn MH; Jeong HJ
    J Korean Med Sci; 2015 Jun; 30(6):816-22. PubMed ID: 26028937
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro uptake of radiocolloids by rat peritoneal macrophages and human tumor cells.
    Nagai K; Ito Y; Otsuka N
    Int J Nucl Med Biol; 1982; 9(2):108-13. PubMed ID: 6286522
    [No Abstract]   [Full Text] [Related]  

  • 13. A crossover study comparing the effect of particle size on the distribution of radiocolloid in patients.
    Kloiber R; Damtew B; Rosenthall L
    Clin Nucl Med; 1981 May; 6(5):204-6. PubMed ID: 6452980
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lymphoscintigraphy: a comparison of 99Tc(m) antimony sulphide colloid and 99Tc(m) stannous phytate.
    Ege GN; Warbick A
    Br J Radiol; 1979 Feb; 52(614):124-9. PubMed ID: 427362
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new formulation of Tc-99m minimicroaggregated albumin for marrow imaging: comparison with other colloids, In-111 and Fe-59.
    McAfee JG; Subramanian G; Aburano T; Thomas FD; Fernandes P; Gagne G; Lyons B; Zapf-Longo C
    J Nucl Med; 1982 Jan; 23(1):21-8. PubMed ID: 6459431
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technetium-99m antimony colloid for bone-marrow imaging.
    Martindale AA; Papadimitriou JM; Turner JH
    J Nucl Med; 1980 Nov; 21(11):1035-41. PubMed ID: 7431102
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiolabeled antibodies, albumin and antimony sulfide colloid: a comparison as lymphoscintigraphic agents.
    Wahl RL; Liebert M; Wilson BS; Petry NA
    Int J Rad Appl Instrum B; 1988; 15(3):243-50. PubMed ID: 3384672
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of [(99m)Tc] liposomes as lymphoscintigraphic agents: comparison with [(99m)Tc] sulfur colloid and [(99m)Tc] human serum albumin.
    Phillips WT; Andrews T; Liu H; Klipper R; Landry AJ; Blumhardt R; Goins B
    Nucl Med Biol; 2001 May; 28(4):435-44. PubMed ID: 11395317
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Biodistribution of Tc-99m-rhenium colloid in rats: a comparison with Tc-99m-sulfur colloid (author's transl)].
    Nakajima K; Koizumi K; Aburano T; Yamada M; Hisada K
    Kaku Igaku; 1981 Aug; 18(7):967-71. PubMed ID: 7321328
    [No Abstract]   [Full Text] [Related]  

  • 20. Absolute quantification of pharmacokinetic distribution of RES colloids in individuals with normal liver function.
    Herzog H; Spohr G; Notohamiprodjo G; Feinendegen LE
    Nucl Med Commun; 1987 Mar; 8(3):157-75. PubMed ID: 3108736
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.