These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 6226029)

  • 21. Devastating late complication for repair of type A acute aortic dissection with usage of gelatin-resorcinol-formalin glue.
    Izutani H; Shibukawa T; Kawamoto J; Ishibashi K; Nishikawa D
    Interact Cardiovasc Thorac Surg; 2007 Apr; 6(2):240-2. PubMed ID: 17669825
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Invited commentary.
    LeMaire SA
    Ann Thorac Surg; 2007 May; 83(5):1626-7. PubMed ID: 17462369
    [No Abstract]   [Full Text] [Related]  

  • 23. Use of glue without graft replacement for type A dissections: a new surgical technique.
    Fabiani JN; Jebara VA; DeLoche A; Carpentier A
    Ann Thorac Surg; 1990 Jul; 50(1):143-5. PubMed ID: 2196015
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Recommendation for appropriate use of GRF glue in the operation for acute aortic dissection.
    Kunihara T; Shiiya N; Matsuzaki K; Murashita T; Matsui Y
    Ann Thorac Cardiovasc Surg; 2008 Apr; 14(2):88-95. PubMed ID: 18414345
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The proper use of glue: a 20-year experience with the GRF glue in acute aortic dissection.
    Bachet J; Goudot B; Dreyfus G; Banfi C; Ayle NA; Aota M; Brodaty D; Dubois C; Delentdecker P; Guilmet D
    J Card Surg; 1997; 12(2 Suppl):243-53; discussion 253-5. PubMed ID: 9271753
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dissected aortic sinuses repaired with gelatin-resorcin-formaldehyde (GRF) glue are not stable on follow up.
    von Oppell UO; Karani Z; Brooks A; Brink J
    J Heart Valve Dis; 2002 Mar; 11(2):249-57. PubMed ID: 12000168
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Embolisation, inflammatory reaction and persistent patent false lumen: is biological glue really effective in repair of type A aortic dissection?
    Mastroroberto P; Chello M; Onorati F; Renzulli A
    Eur J Cardiothorac Surg; 2005 Mar; 27(3):531-2; author reply 532. PubMed ID: 15740977
    [No Abstract]   [Full Text] [Related]  

  • 28. Aortic root necrosis after surgical treatment using gelatin-resorcinol-formaldehyde (GRF) glue in patients with acute type A aortic dissection.
    Suzuki S; Imoto K; Uchida K; Takanashi Y
    Ann Thorac Cardiovasc Surg; 2006 Oct; 12(5):333-40. PubMed ID: 17095975
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Gelatin resorcin formaldehyde glue in vascular surgery (author's transl)].
    Laurian C; Gigou F; Guilmet D
    Nouv Presse Med; 1977 Oct; 6(35):3221-3. PubMed ID: 563061
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Surgery of acute aortic dissection by use of a biological glue. Experimental study (author's transl)].
    Laurian C; Gigou F; Bical O; Barbagelata M; Bachet J; Goudot B; Guilmet D
    J Chir (Paris); 1979 Feb; 116(2):143-8. PubMed ID: 468928
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Surgery for acute type A aortic dissection: the Hopital Foch experience (1977-1998).
    Bachet J; Goudot B; Dreyfus GD; Brodaty D; Dubois C; Delentdecker P; Guilmet D
    Ann Thorac Surg; 1999 Jun; 67(6):2006-9; discussion 2014-9. PubMed ID: 10391359
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Four-year clinical experience with the gelatin-resorcine-formol biological glue in acute aortic dissection.
    Bachet J; Gigou F; Laurian C; Bical O; Goudot B; Guilmet D
    J Thorac Cardiovasc Surg; 1982 Feb; 83(2):212-7. PubMed ID: 6977072
    [No Abstract]   [Full Text] [Related]  

  • 33. Pathologic findings of aortic redissection after glue repair of proximal aorta.
    Yoshitatsu M; Nomura F; Katayama A; Tamura K; Katayama K; Ihara K; Nakashima Y
    J Thorac Cardiovasc Surg; 2004 Feb; 127(2):593-5. PubMed ID: 14762381
    [No Abstract]   [Full Text] [Related]  

  • 34. The use of surgical glue in acute type A aortic dissection.
    Suzuki S; Masuda M; Imoto K
    Gen Thorac Cardiovasc Surg; 2014 Apr; 62(4):207-13. PubMed ID: 24254987
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The use of gelatin-resorcin-formalin glue in acute aortic dissection type A.
    Fukunaga S; Karck M; Harringer W; Cremer J; Rhein C; Haverich A
    Eur J Cardiothorac Surg; 1999 May; 15(5):564-9; discussion 570. PubMed ID: 10386398
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Embolization of biologic glue during repair of aortic dissection.
    Carrel T; Maurer M; Tkebuchava T; Niederhäuser U; Schneider J; Turina MI
    Ann Thorac Surg; 1995 Oct; 60(4):1118-20. PubMed ID: 7574966
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Aortic root replacement with a composite graft wrapped with equine pericardium (Xenomedica) using fibrin glue].
    Aida H; Sakamoto S; Kaneto Y; Shirakawa H; Nakajima M; Shimizu T
    Nihon Kyobu Geka Gakkai Zasshi; 1988 Feb; 36(2):231-5. PubMed ID: 2455010
    [No Abstract]   [Full Text] [Related]  

  • 38. Late results of gelatin-resorcin-formalin glue-aided repair in acute type A aortic dissection.
    Shiono M; Hata M; Sezai A; Niino T; Yagi S; Negishi N
    Artif Organs; 2006 Dec; 30(12):962-5. PubMed ID: 17181838
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Surgery for acute aortic dissection extending to the aortic root using gelatine-resorcine-formol biological glue--a case report].
    Uchida K; Kondo J; Imoto K; Tobe M; Sakamoto A; Sugiyama M
    Nihon Kyobu Geka Gakkai Zasshi; 1997 Jul; 45(7):1024-7. PubMed ID: 9256644
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Clinical experience with the gelatin-resorcine-formol biological glue in acute type A aortic dissection].
    Moriyama Y; Toyohira H; Yotsumoto G; Kinjho T; Matsumoto H; Hisatomi K; Iwamura H; Watanabe S; Shimokawa S; Taira A
    Nihon Kyobu Geka Gakkai Zasshi; 1997 May; 45(5):682-6. PubMed ID: 9170858
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.