These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 6232985)

  • 1. [Study of the corrosion of metallic biomaterials by surface physical methods].
    Muster D; Champy M; Szmukler S; Baltzinger C; Burggraf C
    C R Seances Soc Biol Fil; 1983; 177(4):496-503. PubMed ID: 6232985
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Biodeterioration and corrosion of metallic implants and prostheses].
    López GD
    Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials.
    Lévesque J; Hermawan H; Dubé D; Mantovani D
    Acta Biomater; 2008 Mar; 4(2):284-95. PubMed ID: 18033745
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring of titanium base alloys-biofluids interface.
    Popa MV; Demetrescu I; Suh SH; Vasilescu E; Drob P; Ionita D; Vasilescu C
    Bioelectrochemistry; 2007 Nov; 71(2):126-34. PubMed ID: 17409027
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.
    Oliveira NT; Guastaldi AC
    Acta Biomater; 2009 Jan; 5(1):399-405. PubMed ID: 18707926
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Corrosion behaviour of a beta-titanium alloy.
    Martin E; Manceur A; Polizu S; Savadogo O; Wu MH; Yahia L
    Biomed Mater Eng; 2006; 16(3):171-82. PubMed ID: 16518016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Tissue metallosis of the implant bed as a late complication of metal osteosynthesis].
    Zaitseva KK; Gritsanov AI
    Arkh Patol; 1984; 46(8):37-45. PubMed ID: 6497696
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessing the biocompatibility of degradable metallic materials: state-of-the-art and focus on the potential of genetic regulation.
    Purnama A; Hermawan H; Couet J; Mantovani D
    Acta Biomater; 2010 May; 6(5):1800-7. PubMed ID: 20176149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The issue of corrosion in dental implants: a review.
    Olmedo DG; Tasat DR; Duffó G; Guglielmotti MB; Cabrini RL
    Acta Odontol Latinoam; 2009; 22(1):3-9. PubMed ID: 19601489
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion at the marginal gap of implant-supported suprastructures and implant failure.
    Guindy JS; Schiel H; Schmidli F; Wirz J
    Int J Oral Maxillofac Implants; 2004; 19(6):826-31. PubMed ID: 15623057
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion resistance and ion dissolution of titanium with different surface microroughness.
    Chen G; Wen X; Zhang N
    Biomed Mater Eng; 1998; 8(2):61-74. PubMed ID: 9830989
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of thermal oxidation on corrosion and corrosion-wear behaviour of a Ti-6Al-4V alloy.
    Güleryüz H; Cimenoğlu H
    Biomaterials; 2004 Jul; 25(16):3325-33. PubMed ID: 14980427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corrosion behavior of palladium-silver-copper alloys in model saliva.
    Joska L; Poddana M; Leitner J
    Dent Mater; 2008 Aug; 24(8):1009-16. PubMed ID: 18191189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomaterial optimization in total disc arthroplasty.
    Hallab N; Link HD; McAfee PC
    Spine (Phila Pa 1976); 2003 Oct; 28(20):S139-52. PubMed ID: 14560185
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Fine structure investigations of metallosis in stainless steel allentheses (author's transl)].
    Schuster J; Marquart KH
    MMW Munch Med Wochenschr; 1974 May; 116(19):1001-4. PubMed ID: 4210633
    [No Abstract]   [Full Text] [Related]  

  • 17. Aspects of surface physics on titanium implants.
    Kasemo B; Lausmaa J
    Swed Dent J Suppl; 1985; 28():19-36. PubMed ID: 3904061
    [No Abstract]   [Full Text] [Related]  

  • 18. Accelerated ageing of metallic biomaterials: principle and results.
    Bellier JP; Lecoeur J; Koehler C; Davidas JP
    Biomaterials; 1990 Jul; 11():55-6. PubMed ID: 2397261
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Modern methods for studying the surface of titanium implants (literature review)].
    Suba C; Velich N; Vörös J; Turi C; Szabó G
    Fogorv Sz; 2004 Feb; 97(1):29-35. PubMed ID: 15067890
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.