BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 6235980)

  • 21. Measurement of circulating Clq precipitable immune complexes by a nephelometric type assay after polyethylene glycol extraction in model system.
    Levinson SS; Goldman J
    Am J Clin Pathol; 1983 Apr; 79(4):451-7. PubMed ID: 6188360
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Limitations of polyethylene glycol precipitation assays for circulating immune complexes.
    Traycoff RB; Muegge D; Rogers W
    Am J Clin Pathol; 1981 Dec; 76(6):802-5. PubMed ID: 7315797
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Polyethylene glycol enhances the binding of C1q to circulating immune complexes.
    Hack CE; Eerenberg-Belmer AJ; Hannema AJ; Out TA; Aalberse RC
    J Immunol Methods; 1981; 44(2):211-21. PubMed ID: 6792284
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Detection of immune complexes by a new assay, the polyethylene glycol precipitation-complement consumption test (PEG-CC).
    Harkiss GD; Brown DL
    Clin Exp Immunol; 1979 Apr; 36(1):117-29. PubMed ID: 111880
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Specific proteins precipitated by polyethylene glycol during assays for circulating C1q precipitable immune complexes.
    Hyun J
    Am J Clin Pathol; 1983 Nov; 80(5):777-8. PubMed ID: 6605678
    [No Abstract]   [Full Text] [Related]  

  • 26. Characteristics of immune complexes detectable by two independent assays in gynaecological malignancies.
    Poulton TA; Mooney NA; Nineham LJ; Hay FC
    Clin Exp Immunol; 1983 Sep; 53(3):573-80. PubMed ID: 6604605
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An enzyme-linked immunoassay for detection of IgG- and C3-containing circulating immune complexes: comparison with a radioimmunoassay and quantitation in patients with rheumatic diseases.
    Panush RS; Somberg LB; Katz P; Longley S
    Diagn Immunol; 1983; 1(4):288-94. PubMed ID: 6388973
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Demonstration of circulating immune complexes using a C1q-solid phase enzyme immunoassay].
    Schössler W; Hiepe F; Courault K; Porstmann B; Apostoloff E
    Biomed Biochim Acta; 1983; 42(7-8):1027-35. PubMed ID: 6360166
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Relationship between renal pathology and the size of circulating immune complexes in patients with systemic lupus erythematosus.
    Wener MH; Mannik M; Schwartz MM; Lewis EJ
    Medicine (Baltimore); 1987 Mar; 66(2):85-97. PubMed ID: 3102894
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Detection of circulating immune complexes by three techniques using polyethylene glycol (author's transl)].
    Digeon M; Bach JF
    Nouv Presse Med; 1977 Dec; 6(43):4031-7. PubMed ID: 600749
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Solid phase C1q microassay for the rapid detection of circulating immune complexes.
    Orozco A; Contreras CE; Sánchez P; Meilijson O; Bianco NE
    J Immunol Methods; 1983 Apr; 59(2):237-43. PubMed ID: 6341470
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Anti-C1q column: ligand specific purification of immune complexes from human serum or plasma. Analysis of the interaction between C1q and immune complexes.
    Kilgallon W; Amlot PL; Williams BD
    Clin Exp Immunol; 1982 Jun; 48(3):705-14. PubMed ID: 6811171
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The polyethylene glycol precipitation technique and the particle-counting immunoassay for detection of circulating immune complex-like material in liver cirrhosis and septicemia.
    Fink PC; Schultze KD
    J Lab Clin Med; 1982 Jun; 99(6):852-65. PubMed ID: 7077126
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A PEG-precipitation laser nephelometer technique for detection and characterization of circulating immune complexes in human sera.
    Krapf F; Renger D; Schedel I; Leiendecker K; Leyssens H; Deicher H
    J Immunol Methods; 1982 Oct; 54(1):107-17. PubMed ID: 7142715
    [No Abstract]   [Full Text] [Related]  

  • 35. A solid phase C1q enzyme assay for circulating immune complexes adapted for routine clinical laboratory testing.
    James K; Vahey A; Robinson M; Marder R
    Am J Clin Pathol; 1983 Oct; 80(4):445-52. PubMed ID: 6353904
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Circulating immune complexes, detection in human glomerulonephritis by the PEG-EDTA technique (author's transl)].
    Laurent B; Gonthier R; Genin C; Toulon J; Laurent P; Sabatier JC; Berthoux FC
    Pathol Biol (Paris); 1982 Mar; 30(3):141-6. PubMed ID: 6808442
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A method for rapid determination of IgG containing circulating immune complexes using polyethyleneglycol and radioactively labeled protein A.
    Stevens WJ; Bridts C
    Immunol Lett; 1981 Apr; 3(1):1-4. PubMed ID: 7024111
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Enhancement of the binding of C1q to immune complexes by polyethylene glycol.
    Wines BD; Easterbrook-Smith SB
    Mol Immunol; 1988 Mar; 25(3):263-6. PubMed ID: 3259672
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantitative analysis of the interaction between immune complex and C1q complement subcomponent. The role of interdomain interactions in rabbit IgG in binding of C1q to immune precipitates.
    Vonderviszt F; Török J; Lakatos S; Kilár F; Závodszky P
    Biochem J; 1987 Apr; 243(2):449-55. PubMed ID: 3498482
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Quantitation of immune complexes by nephelometry.
    Höffken K; Bestek U; Sperber U; Schmidt CG
    J Immunol Methods; 1979; 29(3):237-44. PubMed ID: 489992
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.