BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 6235980)

  • 41. Enzyme immunoassay detection of circulating immune complexes by monoclonal antibodies to C3 neoepitopes with special reference to IgG concentration and to interfering anti-immunoglobulin antibodies.
    Garred P; Mollnes TE; Lea T; Lachmann PJ
    J Immunol Methods; 1989 Feb; 117(1):59-66. PubMed ID: 2464039
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Detection and quantitation of immune complexes with a rapid polyethylene glycol precipitation complement consumption method (PEG-CC).
    Brandslund I; Siersted HC; Jensenius JC; Svehag SE
    Methods Enzymol; 1981; 74 Pt C():551-71. PubMed ID: 6459516
    [No Abstract]   [Full Text] [Related]  

  • 43. Serum IgG antibodies to C1q in hypocomplementemic urticarial vasculitis syndrome.
    Wisnieski JJ; Naff GB
    Arthritis Rheum; 1989 Sep; 32(9):1119-27. PubMed ID: 2528353
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Immune complexes in normal subjects.
    Simpson IJ; Myles MJ; Smith GW
    J Clin Lab Immunol; 1983 Jul; 11(3):119-22. PubMed ID: 6350590
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Rapid three-step purification procedure for isolation of the C1q component of human complement and its use in a solid-phase C1q binding assay.
    Bähr EA; Drahovsky D
    J Immunol Methods; 1984 Apr; 69(1):43-50. PubMed ID: 6325543
    [TBL] [Abstract][Full Text] [Related]  

  • 46. C1q binding and Raji immune complex assays: a comparison using defined immunoglobulin aggregates.
    Jones DB; Goulding NJ; Casey CR; Gallagher PJ
    J Immunol Methods; 1982 Sep; 53(2):201-8. PubMed ID: 6982945
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Correlation between circulating antigens detected by the radioimmunoprecipitation-polyethylene glycol assay (RIPEGA) and C1q-binding immune complexes in human schistosomiasis mansoni.
    Santoro F; Prata A; Silva AE; Capron A
    Am J Trop Med Hyg; 1981 Sep; 30(5):1020-5. PubMed ID: 6974508
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Binding characteristics of three complement dependent assays for the detection of immune complexes in human serum.
    Krieger G; Kneba M; Bolz I; Volling P; Wessels J; Nagel GA
    J Clin Lab Immunol; 1985 Nov; 18(3):129-34. PubMed ID: 3878887
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A quantitative examination of the light scattering properties of immune complexes in polyethylene glycol.
    Cohn JR; Buckley CE; Connell C
    J Immunol Methods; 1983 May; 60(1-2):101-13. PubMed ID: 6854025
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Porcine C1q and the solid-phase immunoassay of human immune complexes.
    Ziola B; Salmi A; Penttinen K
    J Immunol Methods; 1982 Mar; 49(3):247-60. PubMed ID: 6978362
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Quantitation of circulating immune complexes by combined PEG precipitation and immunoglobulin-specific radioimmunoassay (PICRIA).
    Siersted HC; Brandslund I; Svehag SE; Jensenius JC
    Methods Enzymol; 1981; 74 Pt C():538-50. PubMed ID: 6459515
    [No Abstract]   [Full Text] [Related]  

  • 52. Measurement of circulating immune complexes in human sera by enzyme immunoassay.
    Cheung K; O'Kane D; Robinson MF
    Aust J Exp Biol Med Sci; 1982 Dec; 60(6):593-605. PubMed ID: 6820632
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Influence of immune complex lattice on the C1q solid phase assay as determined with covalently cross-linked immune complexes.
    Wener MH; Mannik M
    Clin Exp Immunol; 1983 Jun; 52(3):543-50. PubMed ID: 6603296
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Detection of circulating immune complexes in human sera by simplified assays with polyethylene glycol.
    Digeon M; Laver M; Riza J; Bach JF
    J Immunol Methods; 1977; 16(2):165-83. PubMed ID: 881555
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Reactivity of low molecular weight material in cellular immune complex assays.
    Cooper KM; Moore M
    Clin Exp Immunol; 1983 May; 52(2):407-16. PubMed ID: 6602679
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Characterization of immune complex components by dot blot analysis.
    Hoffman WL; Kelly PJ; Ruggles AO
    Anal Biochem; 1992 Nov; 207(1):44-50. PubMed ID: 1489098
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Detection of circulating antigen-antibody complexes by precipitation with C1q and polyethylene glycol].
    Nydegger U; Gerber H; Lambert PH; Miescher PA
    Schweiz Med Wochenschr; 1974 Jan; 104(4):126-7. PubMed ID: 4544103
    [No Abstract]   [Full Text] [Related]  

  • 58. Circulating immune complexes and rheumatoid arthritis.
    Faaber P; Rijke Schilder TP; Capel PJ; Koene RA
    J Rheumatol; 1985 Oct; 12(5):849-53. PubMed ID: 3878875
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A method for studying insoluble immune complexes.
    Khlebtsov BN; Burygin GL; Matora LY; Shchyogolev SY; Khlebtsov NG
    Biochim Biophys Acta; 2004 Feb; 1670(3):199-207. PubMed ID: 14980446
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Detection and quantitation of circulating immune complexes by the C1q-protein A binding assay (C1q-PABA).
    Glikmann G; Svehag SE
    Methods Enzymol; 1981; 74 Pt C():571-88. PubMed ID: 6798369
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.