These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
83 related articles for article (PubMed ID: 626368)
1. A diaphragm delivery device for flow microcalorimetry. Picker P; Miller JF; Bolen DW Anal Biochem; 1978 Jan; 84(1):240-5. PubMed ID: 626368 [No Abstract] [Full Text] [Related]
2. The application of immobilized enzymes in flow microcalorimetry. Johansson A; Lundberg J; Mattiasson B; Mosbach K Biochim Biophys Acta; 1973 Mar; 304(1):217-21. PubMed ID: 4735540 [No Abstract] [Full Text] [Related]
3. Titration microcalorimetry. Doyle ML Curr Protoc Protein Sci; 2001 May; Chapter 20():Unit20.4. PubMed ID: 18429159 [TBL] [Abstract][Full Text] [Related]
4. Thermodynamic flow methods in biochemistry: calorimetry, densimetry, and dilatometry. Jolicoeur C Methods Biochem Anal; 1981; 27():171-287. PubMed ID: 6455585 [No Abstract] [Full Text] [Related]
5. New mixing system in dissolution isoperibol microcalorimeter. Moreno-Piraján JC; Giraldo-Gutierréz L Rev Sci Instrum; 2007 Apr; 78(4):046105. PubMed ID: 17477696 [TBL] [Abstract][Full Text] [Related]
6. Analytical application of microcalorimetry: a stop-flow mixing device. Pennington SN; Brown HD; Berger RL; Evans WJ Anal Biochem; 1969 Nov; 32(2):251-7. PubMed ID: 5396933 [No Abstract] [Full Text] [Related]
7. Operation of a multichannel microcalorimetry system in the micro-submicrowatt region: some methodological aspects. Thorén SA; Suurkuusk J; Holma B J Biochem Biophys Methods; 1989 Mar; 18(2):149-56. PubMed ID: 2745930 [TBL] [Abstract][Full Text] [Related]
13. Stopped flow microcalorimetry without adiabatic compression:application to reactions with half-lives between 3 and 50 ms. Bowen P; Balko B; Blevins K; Berger RL; Hopkins HP Anal Biochem; 1980 Mar; 102(2):434-40. PubMed ID: 6775555 [No Abstract] [Full Text] [Related]
14. [Heat flow meter for measuring regional heat flux in man (author's transl)]. Tamura T; Nemoto T; Togawa T Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1981; 15():103-8. PubMed ID: 6213990 [No Abstract] [Full Text] [Related]
15. A small volume microcalorimeter for analytical determinations. Pennington SN Anal Biochem; 1976 May; 72():230-7. PubMed ID: 942050 [No Abstract] [Full Text] [Related]
16. [Thermostat for microcalorimetry]. Red'ko IuF; Demchuk BN Med Tekh; 1974; (6):32-4. PubMed ID: 4444485 [No Abstract] [Full Text] [Related]
17. A system of micro-calorimeters and its use in biochemistry and biology. Wadsö I Biochem Soc Trans; 1976; 4(4):561-5. PubMed ID: 1001724 [No Abstract] [Full Text] [Related]
18. Analogue circuit for accurate evaluation of small power inputs in microcalorimetry. Forrest WW; Stephen VA J Sci Instrum; 1968 Oct; 1(10):1024-5. PubMed ID: 5703089 [No Abstract] [Full Text] [Related]
19. Sample purification on a microfluidic device. Footz T; Wunsam S; Kulak S; Crabtree HJ; Glerum DM; Backhouse CJ Electrophoresis; 2001 Oct; 22(18):3868-75. PubMed ID: 11700715 [TBL] [Abstract][Full Text] [Related]