These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 630885)

  • 1. Intrauterine devices and menstrual blood loss. A comparative study of eight devices during the first six months of use.
    Gallegost AJ; Aznar R; Merino G; Guizer E
    Contraception; 1978 Feb; 17(2):153-61. PubMed ID: 630885
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Menstrual blood loss, haemoglobin and ferritin concentration of Beijing women wearing steel ring, VCu 200, and TCu 220c IUDs.
    Gao J; Zeng S; Sun BL; Wu SC; Dong J; Cong J; Zhu XH; Fan HM; Han LH; Xie Z
    Contraception; 1986 Dec; 34(6):559-71. PubMed ID: 3829674
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative menstrual and intermenstrual blood loss in women using Lippes Loop and Copper T intrauterine devices.
    Shaw ST; Andrade AT; Paixão de Souza J; Macaulay LK; Rowe PJ
    Contraception; 1980 Apr; 21(4):343-52. PubMed ID: 7389355
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Menstrual bleeding with copper-covered intrauterine contraceptive devices.
    Malmqvist R; Petersohn L; Bengtsson LP
    Contraception; 1974 Jun; 9(6):627-33. PubMed ID: 4448089
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative studies on menstrual blood loss in IUD users.
    Andrade AT; Pizarro Orchard E
    Contraception; 1987 Jul; 36(1):129-44. PubMed ID: 3311622
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reduced menstrual blood loss by release of an antifibrinolytic agent from intrauterine contraceptive devices.
    Tauber PF; Kloppel A; Goodpasture JC; Burns J; Ludwig H; Zaneveld LJ
    Am J Obstet Gynecol; 1981 Jun; 140(3):322-8. PubMed ID: 7246636
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative quantitation of menstrual blood loss with the Lippes Loop, Dalkon Shield, and copper T intrauterine devices.
    Israel R; Shaw ST; Martin MA
    Contraception; 1974 Jul; 10(1):63-71. PubMed ID: 4442266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of prior pregnancy and combined oral contraceptives on baseline menstrual blood loss and bleeding response to intrauterine devices.
    Andrade AT; de Souza JP; Rowe PJ; Shaw ST
    Contraception; 1979 Jul; 20(1):19-26. PubMed ID: 477314
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A randomized, multi-center comparative study of 3 types of IUD (2 years follow-up)].
    China. National IUD Clinical Research Group
    Shengzhi Yu Biyun; 1987 Aug; 7(3):39-47. PubMed ID: 12315172
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of copper surface area on menstrual blood loss and iron status in women fitted with an IUD.
    Milsom I; Rybo G; Lindstedt G
    Contraception; 1990 Mar; 41(3):271-81. PubMed ID: 2323218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Menstrual blood loss in IUD users: comparative study of eleven different IUDs in Mexican women.
    Pedron N
    Adv Contracept Deliv Syst; 1995; 11(3-4):245-53. PubMed ID: 12290877
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of intrauterine devices on menstrual blood loss.
    Gao J; Zeng S; Ma LY; Fan HM; Hu XL; Han LH
    Acta Acad Med Wuhan; 1984; 4(3):140-4. PubMed ID: 6483311
    [No Abstract]   [Full Text] [Related]  

  • 13. [Menstrual blood loss and body iron stores: comparative study between a Multiload-375 IUD and a levonorgestrel vaginal ring].
    Souza JP; Andrade AT; Pizarro E
    Bol Cent Biol Reprod; 1991; 10(1):26-32. PubMed ID: 12318141
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Menstrual blood loss of TCu-380 A and TCu-200 B IUDs.
    El-sheikha Z; Hamza A; Mahmoud M
    Popul Sci; 1990 Jul; ():55-62. PubMed ID: 12343358
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Serum cortisol level in lactating women using Progestasert system.
    Askalani H; Badraoui MH; Mahrous T; Osman MI; Bayad MA; Ibrahim II; Abdalla MI
    Popul Sci; 1981; (2):109-14. PubMed ID: 12339476
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Serum prolactin levels in lactating women using progestasert system.
    Badraoui MH; Askalani H; Mahrous I; Osman MI; Bayad MA; Ibrahim II; Abdalla MT
    Popul Sci; 1981; (2):115-20. PubMed ID: 12339477
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The role of the levonorgestrel intrauterine device in the prevention and treatment of iron deficiency anemia during fertility regulation.
    Faundes A; Alvarez F; Brache V; Tejada AS
    Int J Gynaecol Obstet; 1988 Jun; 26(3):429-33. PubMed ID: 2900174
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The response of endometrial blood vessels to intrauterine contraceptive devices: an electron microscopic study.
    Sheppard BL; Bonnar J
    Br J Obstet Gynaecol; 1980 Feb; 87(2):143-54. PubMed ID: 7362802
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fibrin and platelets in menstrual discharge before and after the insertion of an intrauterine contraceptive device.
    Christiaens GC; Sixma JJ; Haspels AA
    Am J Obstet Gynecol; 1981 Aug; 140(7):793-98. PubMed ID: 7258261
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The menstrual cycle in women using an intrauterine device.
    Faundes A; Segal SJ; Adejuwon CA; Brache V; Leon P; Alvarez-Sanchez F
    Fertil Steril; 1980 Nov; 34(5):427-30. PubMed ID: 7439408
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.