These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 6334858)

  • 1. Convolutional image reconstruction for quantitative single photon emission computed tomography.
    Tanaka E; Toyama H; Murayama H
    Phys Med Biol; 1984 Dec; 29(12):1489-500. PubMed ID: 6334858
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography.
    Tanaka E
    J Comput Assist Tomogr; 1983 Aug; 7(4):692-700. PubMed ID: 6602821
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Distance-weighted backprojection: a SPECT reconstruction technique.
    Nowak DJ; Eisner RL; Fajman WA
    Radiology; 1986 May; 159(2):531-6. PubMed ID: 3485803
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.
    Xu XL; Liow JS; Strother SC
    Med Phys; 1993; 20(6):1675-84. PubMed ID: 8309440
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of attenuation correction methods for quantitative single photon emission computed tomography.
    Webb S; Flower MA; Ott RJ; Leach MO
    Phys Med Biol; 1983 Sep; 28(9):1045-56. PubMed ID: 6605542
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT).
    Murase K; Itoh H; Mogami H; Ishine M; Kawamura M; Iio A; Hamamoto K
    Eur J Nucl Med; 1987; 13(2):55-62. PubMed ID: 3497035
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correction of nonuniform attenuation in cardiac SPECT imaging.
    Tsui BM; Gullberg GT; Edgerton ER; Ballard JG; Perry JR; McCartney WH; Berg J
    J Nucl Med; 1989 Apr; 30(4):497-507. PubMed ID: 2786944
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An analytical approach to quantitative reconstruction of non-uniform attenuated brain SPECT.
    Liang Z; Ye J; Harrington DP
    Phys Med Biol; 1994 Nov; 39(11):2023-41. PubMed ID: 15560008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An analytical approach to single photon emission computed tomography with the attenuation effect.
    Soussaline FP; Cao A; Le Coq G; Raynaud C; Kellershohn C
    Eur J Nucl Med; 1982; 7(11):487-93. PubMed ID: 6983440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Image reconstruction algorithm for single-photon-emission computed tomography with uniform attenuation.
    Inouye T; Kose K; Hasegawa A
    Phys Med Biol; 1989 Mar; 34(3):299-304. PubMed ID: 2784575
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels: Tapping the Potential of a New Technology for Stent Imaging.
    von Spiczak J; Mannil M; Peters B; Hickethier T; Baer M; Henning A; Schmidt B; Flohr T; Manka R; Maintz D; Alkadhi H
    Invest Radiol; 2018 Aug; 53(8):486-494. PubMed ID: 29794949
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative multi-detector emission computerized tomography using iterative attenuation compensation.
    Moore SC; Brunelle JA; Kirsch CM
    J Nucl Med; 1982 Aug; 23(8):706-14. PubMed ID: 6980972
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapidly converging iterative reconstruction algorithms in single-photon emission computed tomography.
    Wallis JW; Miller TR
    J Nucl Med; 1993 Oct; 34(10):1793-800. PubMed ID: 8410300
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An analytical approach for compensation of non-uniform attenuation in cardiac SPECT imaging.
    Glick SJ; King MA; Pan TS; Soares EJ
    Phys Med Biol; 1995 Oct; 40(10):1677-93. PubMed ID: 8532748
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative image reconstruction in PET from emission data only using cluster analysis.
    Landmann M; Glatting G
    Z Med Phys; 2003; 13(4):269-74. PubMed ID: 14732957
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Statistical noise with the weighted backprojection method for single photon emission computed tomography].
    Murayama H; Tanaka E; Toyama H
    Kaku Igaku; 1985 Mar; 22(3):307-19. PubMed ID: 3874979
    [No Abstract]   [Full Text] [Related]  

  • 17. Impact of the Adaptive Statistical Iterative Reconstruction Technique on Radiation Dose and Image Quality in Bone SPECT/CT.
    Sibille L; Chambert B; Alonso S; Barrau C; D'Estanque E; Al Tabaa Y; Collombier L; Demattei C; Kotzki PO; Boudousq V
    J Nucl Med; 2016 Jul; 57(7):1091-5. PubMed ID: 27013695
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection.
    Jaszczak RJ; Floyd CE; Manglos SH; Greer KL; Coleman RE
    Med Phys; 1986; 13(4):484-9. PubMed ID: 3488496
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.
    Lartizien C; Kinahan PE; Swensson R; Comtat C; Lin M; Villemagne V; Trébossen R
    J Nucl Med; 2003 Feb; 44(2):276-90. PubMed ID: 12571221
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-resolution image reconstruction method for time-of-flight positron emission tomography.
    Yamaya T; Obi T; Yamaguchi M; Ohyama N
    Phys Med Biol; 2000 Nov; 45(11):3125-34. PubMed ID: 11098893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.