BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 6335066)

  • 1. Anti-IgG type test to assay circulating immune complexes from polyethylene glycol precipitates compared with C1q binding and Raji cell tests.
    Levinson SS; Goldman J
    Clin Biochem; 1984 Dec; 17(6):341-4. PubMed ID: 6335066
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Anti-IgG binding test to assay circulating IgG-containing immune complexes from polyethylene glycol precipitates.
    Levinson SS; Goldman JO; Feldkamp CS
    Clin Chem; 1984 Sep; 30(9):1502-6. PubMed ID: 6235980
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Clinical significances of circulating immune complexes in connective tissue diseases--detection by C1q deviation test, precipitin reaction of C1q in gel diffusion, anti-antibody inhibition test and precipitation with polyethylene glycol].
    Yasuda M
    Ryumachi; 1983 Oct; 23(5):315-26. PubMed ID: 6608796
    [No Abstract]   [Full Text] [Related]  

  • 4. Evaluation of anti-C1q capture assay for detecting circulating immune complexes and comparison with polyethylene glycol-immunoglobulin G, C1q-binding, and Raji cell methods.
    Levinson SS; Goldman JO
    J Clin Microbiol; 1987 Aug; 25(8):1567-9. PubMed ID: 2957387
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Absorbance nephelometry of immune complexes by reaction with anti-IgG after treatment with polyethylene glycol.
    Levinson SS; Goldman J
    Clin Chem; 1983 Dec; 29(12):2035-9. PubMed ID: 6605818
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhancement of the binding of C1q to immune complexes by polyethylene glycol.
    Wines BD; Easterbrook-Smith SB
    Mol Immunol; 1988 Mar; 25(3):263-6. PubMed ID: 3259672
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Absorbance nephelometry of C1q-precipitable immune complexes: method comparisons and clinical correlations.
    Levinson SS; Goldman J
    Clin Chem; 1983 Dec; 29(12):2082-6. PubMed ID: 6605819
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Anti-IgG combined with rate nephelometry for measuring polyethylene glycol-precipitated circulating immune complexes.
    Feldkamp CS; Levinson SS; Perry M; Amin V
    Clin Chem; 1985 Dec; 31(12):2024-7. PubMed ID: 4064293
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Differential precipitation of the Clq subcomponent of the first complement component (C1) by polyethylene glycol from normal human serum and sera of patients with collagen diseases.
    Van Dijk H; Van Voorst J; Jankowski IG; Imhof JW; Kerckhaert JA
    Clin Exp Immunol; 1984 Aug; 57(2):495-501. PubMed ID: 6432386
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A solid phase C1q enzyme assay for circulating immune complexes adapted for routine clinical laboratory testing.
    James K; Vahey A; Robinson M; Marder R
    Am J Clin Pathol; 1983 Oct; 80(4):445-52. PubMed ID: 6353904
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative study of complement components in polyethylene glycol precipitated immune complexes from patients with ovarian cancer and patients with rheumatoid arthritis.
    Mooney NA; Hay FC; Poulton TA
    Clin Exp Immunol; 1983 Jun; 52(3):561-8. PubMed ID: 6603297
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of the soluble immune complexes that are detected by three different techniques.
    van der Giessen M; The TH
    Clin Immunol Immunopathol; 1986 Feb; 38(2):244-55. PubMed ID: 3484441
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fluorescent anti-immunoglobulin G assay of circulating immune complexes extracted with polyethylene glycol.
    Levinson SS; Goldman J
    J Clin Microbiol; 1986 Jan; 23(1):29-32. PubMed ID: 3517044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anti-C1q column: ligand specific purification of immune complexes from human serum or plasma. Analysis of the interaction between C1q and immune complexes.
    Kilgallon W; Amlot PL; Williams BD
    Clin Exp Immunol; 1982 Jun; 48(3):705-14. PubMed ID: 6811171
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative analysis of the interaction between immune complex and C1q complement subcomponent. The role of interdomain interactions in rabbit IgG in binding of C1q to immune precipitates.
    Vonderviszt F; Török J; Lakatos S; Kilár F; Závodszky P
    Biochem J; 1987 Apr; 243(2):449-55. PubMed ID: 3498482
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of circulating immune complexes in human sera by enzyme immunoassay.
    Cheung K; O'Kane D; Robinson MF
    Aust J Exp Biol Med Sci; 1982 Dec; 60(6):593-605. PubMed ID: 6820632
    [TBL] [Abstract][Full Text] [Related]  

  • 17. C1q-latex assay for immune complexes. Complexes that react with both C1q and monoclonal rheumatoid factor in lupus erythematosus and lung cancer.
    Medof ME
    J Lab Clin Med; 1982 May; 99(5):678-92. PubMed ID: 6978370
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation between circulating antigens detected by the radioimmunoprecipitation-polyethylene glycol assay (RIPEGA) and C1q-binding immune complexes in human schistosomiasis mansoni.
    Santoro F; Prata A; Silva AE; Capron A
    Am J Trop Med Hyg; 1981 Sep; 30(5):1020-5. PubMed ID: 6974508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polyethylene glycol enhances the binding of C1q to circulating immune complexes.
    Hack CE; Eerenberg-Belmer AJ; Hannema AJ; Out TA; Aalberse RC
    J Immunol Methods; 1981; 44(2):211-21. PubMed ID: 6792284
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Circulating immune complexes in the serum in systemic lupus erythematosus and in carriers of hepatitis B antigen. Quantitation by binding to radiolabeled C1q.
    Nydegger UE; Lambert PH; Gerber H; Miescher PA
    J Clin Invest; 1974 Aug; 54(2):297-309. PubMed ID: 4847246
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.