BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 6337344)

  • 21. Fluorescence ELISA based on glucose oxidase-mediated fluorescence quenching of quantum dots for highly sensitive detection of Hepatitis B.
    Wu Y; Zeng L; Xiong Y; Leng Y; Wang H; Xiong Y
    Talanta; 2018 May; 181():258-264. PubMed ID: 29426510
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Time-resolved fluoroimmunoassay for detecting hepatitis B virus surface antigen].
    Lin DQ; Shen J
    Nan Fang Yi Ke Da Xue Xue Bao; 2007 Oct; 27(10):1575-6. PubMed ID: 17959541
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A novel bifunctional europium chelate applied in quantitative determination of human immunoglobin G using time-resolved fluoroimmunoassay.
    Niu CG; Liu J; Qin PZ; Zeng GM; Ruan M; He H
    Anal Biochem; 2011 Feb; 409(2):244-8. PubMed ID: 20946867
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Rapid and sensitive HBsAg immunoassay based on fluorescent nanoparticle labels and time-resolved detection.
    Valanne A; Huopalahti S; Vainionpää R; Lövgren T; Härmä H
    J Virol Methods; 2005 Oct; 129(1):83-90. PubMed ID: 15996764
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Time-resolved flow cytometry for the measurement of lanthanide chelate fluorescence: I. Concept and theoretical evaluation.
    Condrau MA; Schwendener RA; Niederer P; Anliker M
    Cytometry; 1994 Jul; 16(3):187-94. PubMed ID: 7924687
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Comparison of the DELFIA and RIA methods for measuring luteinizing and follicle stimulating hormones in serum].
    Menjívar M; Ortiz G; Cárdenas M; Garza-Flores J
    Rev Invest Clin; 1993; 45(6):579-84. PubMed ID: 8159879
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Spectroscopic evaluation of time-resolved fluoroimmunoassay].
    Guo ZY; Tian Z; Jia YL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2004 May; 24(5):596-9. PubMed ID: 15769056
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Time-resolved fluoroimmunoassay (TR-FIA) of gonadotropins.
    Iwasawa A; Tomizawa K; Kato T; Wakabayashi K; Kato Y
    Exp Clin Endocrinol; 1994; 102(1):39-43. PubMed ID: 8005207
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Investigation of dissociation enhanced lanthanide fluoroimmunoassay as an alternative screening test for veterinary drug residues.
    Elliott CT; Francis KS; McCaughey WJ
    Analyst; 1994 Dec; 119(12):2565-9. PubMed ID: 7879855
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A dissociative fluorescence enhancement technique for one-step time-resolved immunoassays.
    Blomberg KR; Mukkala VM; Hakala HH; Mäkinen PH; Suonpää MU; Hemmilä IA
    Anal Bioanal Chem; 2011 Feb; 399(4):1677-82. PubMed ID: 21161513
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Europium(III)-chelates embedded in nanoparticles are protected from interfering compounds present in assay media.
    Kokko L; Lövgren T; Soukka T
    Anal Chim Acta; 2007 Feb; 585(1):17-23. PubMed ID: 17386642
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A rapid and sensitive method based on magnetic beads for the detection of hepatitis B virus surface antigen in human serum.
    Ren ZQ; Liu TC; Hou JY; Chen MJ; Chen ZH; Lin GF; Wu YS
    Luminescence; 2014 Sep; 29(6):591-7. PubMed ID: 24136927
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Time-resolved fluoroimmunoassay (TR-FIA) of porcine relaxin.
    Ogine T; Kohsaka T; Taya K
    Exp Clin Endocrinol Diabetes; 1999; 107(4):276-80. PubMed ID: 10433068
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Activated phosphonated trifunctional chelates for highly sensitive lanthanide-based FRET immunoassays applied to total prostate specific antigen detection.
    Nchimi-Nono K; Wegner KD; Lindén S; Lecointre A; Ehret-Sabatier L; Shakir S; Hildebrandt N; Charbonnière LJ
    Org Biomol Chem; 2013 Oct; 11(38):6493-501. PubMed ID: 23851931
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Immunoassays with time-resolved fluorescence spectroscopy: principles and applications.
    Diamandis EP
    Clin Biochem; 1988 Jun; 21(3):139-50. PubMed ID: 3292080
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fluoroimmunoassays and immunofluorometric assays.
    Hemmilä I
    Clin Chem; 1985 Mar; 31(3):359-70. PubMed ID: 3882272
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Simultaneous determination of alpha-fetoprotein and carcinoembryonic antigen in human serum by time-resolved fluoroimmunoassay.
    Matsumoto K; Yuan J; Wang G; Kimura H
    Anal Biochem; 1999 Dec; 276(1):81-7. PubMed ID: 10585747
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Homogeneous time-resolved fluoroimmunoassay of bensulfuron-methyl by using terbium fluorescence energy transfer.
    Wang G; Yuan J; Matsumoto K; Hu Z
    Talanta; 2001 Dec; 55(6):1119-25. PubMed ID: 18968465
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Time-resolved flow cytometry for the measurement of lanthanide chelate fluorescence: II. Instrument design and experimental results.
    Condrau MA; Schwendener RA; Zimmermann M; Muser MH; Graf U; Niederer P; Anliker M
    Cytometry; 1994 Jul; 16(3):195-205. PubMed ID: 7924688
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Analysis of clinical characteristics and S gene mutation of hepatitis B virus (HBV) in patients with hepatitis B surface antigen RIA negative and HBV DNA positive].
    Sohn YH; Oh HB; Ko SY; Lim YS; Kwon OJ
    Korean J Lab Med; 2009 Jun; 29(3):224-30. PubMed ID: 19571620
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.