189 related articles for article (PubMed ID: 6340543)
1. A C1Q enzyme-linked immunosorbent assay (ELISA) using polyethylene glycol for immune complexes.
Lunde MN
Am J Trop Med Hyg; 1983 Mar; 32(2):392-6. PubMed ID: 6340543
[TBL] [Abstract][Full Text] [Related]
2. Circulating immune complexes in the serum in systemic lupus erythematosus and in carriers of hepatitis B antigen. Quantitation by binding to radiolabeled C1q.
Nydegger UE; Lambert PH; Gerber H; Miescher PA
J Clin Invest; 1974 Aug; 54(2):297-309. PubMed ID: 4847246
[TBL] [Abstract][Full Text] [Related]
3. Detection of C1q-bearing immune complexes by a monoclonal anti-C1q ELISA system.
Antes U; Heinz HP; Loos M
J Immunol Methods; 1987 Sep; 102(2):149-56. PubMed ID: 2443573
[TBL] [Abstract][Full Text] [Related]
4. C1q binding and C1q deviation assays using enzyme labelled C1q.
Smith GW; Myles MJ; Simpson IJ
J Immunol Methods; 1984 Feb; 67(1):167-72. PubMed ID: 6366065
[TBL] [Abstract][Full Text] [Related]
5. Detection of circulating immune complexes with polyethylene glycol precipitation F(ab')2 anti-C3 ELISA.
Xu RJ; Gu YA
J Immunol Methods; 1990 Dec; 135(1-2):225-31. PubMed ID: 2273258
[TBL] [Abstract][Full Text] [Related]
6. Estimation of immune complexes by a microplate-adapted C1q-Protein A enzyme-linked-immunosorbent-assay (C1q-PA-ELISA).
Bjerrum L; Glikmann G; Jensenius JC; Svehag SE
J Clin Lab Immunol; 1983 Jan; 10(1):53-8. PubMed ID: 6338238
[TBL] [Abstract][Full Text] [Related]
7. The IgG detected in the C1q solid-phase immune-complex assay is not always of immune-complex nature.
Hack CE; Belmer AJ
Clin Immunol Immunopathol; 1986 Jan; 38(1):120-8. PubMed ID: 3484437
[TBL] [Abstract][Full Text] [Related]
8. [Demonstration of circulating immune complexes using a C1q-solid phase enzyme immunoassay].
Schössler W; Hiepe F; Courault K; Porstmann B; Apostoloff E
Biomed Biochim Acta; 1983; 42(7-8):1027-35. PubMed ID: 6360166
[TBL] [Abstract][Full Text] [Related]
9. [Use of solid-phase Clq-ELISA for detecting circulating immune complexes in human diseases].
Aleshkin VA; Nasonov EL; Eremeeva MV; Kobylianskiĭ AG
Ter Arkh; 1989; 61(6):113-6. PubMed ID: 2477907
[TBL] [Abstract][Full Text] [Related]
10. Immunochemical analyses of components of immune complexes in the sera of patients with autoimmune diseases.
Ferraccioli G; Karsh J; Osterland CK
J Rheumatol; 1983 Dec; 10(6):881-8. PubMed ID: 6663592
[TBL] [Abstract][Full Text] [Related]
11. Tests for circulating immune complexes.
Wener MH
Methods Mol Biol; 2014; 1134():47-57. PubMed ID: 24497353
[TBL] [Abstract][Full Text] [Related]
12. Circulating immune complexes in pregnancy, preeclampsia, and autoimmune diseases: evaluation of Raji cell enzyme-linked immunosorbent assay and polyethylene glycol precipitation methods.
Rote NS; Caudle MR
Am J Obstet Gynecol; 1983 Oct; 147(3):267-73. PubMed ID: 6353922
[TBL] [Abstract][Full Text] [Related]
13. [Determination of circulating immune complexes and of their component immunoglobulin classes M, G, and A with a C1q-ELISA].
Sequeira Peña GA; Herrmann D; Vogt KH; Jäger L
Allerg Immunol (Leipz); 1991; 37(1):37-45. PubMed ID: 2063729
[TBL] [Abstract][Full Text] [Related]
14. Comparative study of circulating immune complexes quantity detection by three assays--CIF-ELISA, C1q-ELISA and anti-C3 ELISA.
Stanilova SA; Slavov ES
J Immunol Methods; 2001 Jul; 253(1-2):13-21. PubMed ID: 11384665
[TBL] [Abstract][Full Text] [Related]
15. Altered glycosylation of complexed native IgG molecules is associated with disease activity of systemic lupus erythematosus.
Sjöwall C; Zapf J; von Löhneysen S; Magorivska I; Biermann M; Janko C; Winkler S; Bilyy R; Schett G; Herrmann M; Muñoz LE
Lupus; 2015 May; 24(6):569-81. PubMed ID: 25389233
[TBL] [Abstract][Full Text] [Related]
16. Polyethylene glycol precipitates of serum contain a large proportion of uncomplexed immunoglobulins and C3.
Crowley-Nowick PA; Campbell E; Schrohenloher RE; Mestecky J; Mestecky J; Jackson S
Immunol Invest; 1996; 25(1-2):91-101. PubMed ID: 8675237
[TBL] [Abstract][Full Text] [Related]
17. A solid phase C1q enzyme assay for circulating immune complexes adapted for routine clinical laboratory testing.
James K; Vahey A; Robinson M; Marder R
Am J Clin Pathol; 1983 Oct; 80(4):445-52. PubMed ID: 6353904
[TBL] [Abstract][Full Text] [Related]
18. [Detection of circulating immune complexes by three techniques using polyethylene glycol (author's transl)].
Digeon M; Bach JF
Nouv Presse Med; 1977 Dec; 6(43):4031-7. PubMed ID: 600749
[TBL] [Abstract][Full Text] [Related]
19. Detection of circulating immune complexes by PEG precipitation combined with ELISA.
Ohlson S; Zetterstrand K
J Immunol Methods; 1985 Feb; 77(1):87-93. PubMed ID: 3973400
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of anti-C1q capture assay for detecting circulating immune complexes and comparison with polyethylene glycol-immunoglobulin G, C1q-binding, and Raji cell methods.
Levinson SS; Goldman JO
J Clin Microbiol; 1987 Aug; 25(8):1567-9. PubMed ID: 2957387
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]