BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 6341470)

  • 1. Solid phase C1q microassay for the rapid detection of circulating immune complexes.
    Orozco A; Contreras CE; Sánchez P; Meilijson O; Bianco NE
    J Immunol Methods; 1983 Apr; 59(2):237-43. PubMed ID: 6341470
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Circulating immune complexes in systemic lupus erythematosus: a reappraisal of the solid phase C1q radioimmunoassay.
    Woodroffe AJ; Nozza JM; Muller KD; McIntosh SL; Hale GM; Clarkson AR
    J Clin Lab Immunol; 1988 May; 26(1):5-7. PubMed ID: 3263507
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of circulating immune complexes in human sera by enzyme immunoassay.
    Cheung K; O'Kane D; Robinson MF
    Aust J Exp Biol Med Sci; 1982 Dec; 60(6):593-605. PubMed ID: 6820632
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A solid phase C1q enzyme assay for circulating immune complexes adapted for routine clinical laboratory testing.
    James K; Vahey A; Robinson M; Marder R
    Am J Clin Pathol; 1983 Oct; 80(4):445-52. PubMed ID: 6353904
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Determination of immune complex levels--with special reference to C1q and the anti-antibody method].
    Kasukawa R
    Rinsho Byori; 1986 Oct; Spec No 69():35-44. PubMed ID: 3543438
    [No Abstract]   [Full Text] [Related]  

  • 6. C1q binding and C1q deviation assays using enzyme labelled C1q.
    Smith GW; Myles MJ; Simpson IJ
    J Immunol Methods; 1984 Feb; 67(1):167-72. PubMed ID: 6366065
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Circulating C1q binding immune complexes in relatives of patients with systemic lupus erythematosus.
    Elkon KB; Walport MJ; Rynes RI; Black CM; Batchelor JR; Hughes GR
    Arthritis Rheum; 1983 Jul; 26(7):921-4. PubMed ID: 6603223
    [No Abstract]   [Full Text] [Related]  

  • 8. Characterization of C1q-binding IgG complexes in systemic lupus erythematosus.
    Uwatoko S; Aotsuka S; Okawa M; Egusa Y; Yokohari R; Aizawa C; Suzuki K
    Clin Immunol Immunopathol; 1984 Jan; 30(1):104-16. PubMed ID: 6421520
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Immune complexes in systemic sclerosis; detection by C1q binding, K-cell inhibition and Raji cell radioimmunoassays.
    Hughes P; Cunningham J; Day M; Fitzgerald JC; French MA; Wright JK; Rowell NR
    J Clin Lab Immunol; 1983 Mar; 10(3):133-8. PubMed ID: 6601718
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Demonstration of circulating immune complexes using a C1q-solid phase enzyme immunoassay].
    Schössler W; Hiepe F; Courault K; Porstmann B; Apostoloff E
    Biomed Biochim Acta; 1983; 42(7-8):1027-35. PubMed ID: 6360166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of immune complexes in systemic lupus erythematosus with the C1q solid phase assay: correlation with nDNA antibodies and hypocomplementemia.
    Agnello V; Mitamura T
    Clin Immunol Immunopathol; 1987 Mar; 42(3):338-43. PubMed ID: 3493866
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of circulating immune complexes by a C1q-microplate ELISA system.
    Singh VK; Tingle AJ
    J Immunol Methods; 1982; 50(1):109-14. PubMed ID: 6177790
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of circulating immune complexes in lupus nephritis by solid phase C1q and conglutinin binding assays.
    Yoshida H; Muso E; Inoue S; Furukawa F; Sekita K; Kawai C; Hamashima Y
    Nihon Jinzo Gakkai Shi; 1984 Mar; 26(3):293-300. PubMed ID: 6611433
    [No Abstract]   [Full Text] [Related]  

  • 14. A Clq solid phase microenzymatic assay for the detection of soluble immune complexes.
    Cordiali Fei P; Natali PG
    Ric Clin Lab; 1981; 11(3):207-14. PubMed ID: 6974886
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of C1q-bearing immune complexes by a monoclonal anti-C1q ELISA system.
    Antes U; Heinz HP; Loos M
    J Immunol Methods; 1987 Sep; 102(2):149-56. PubMed ID: 2443573
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of immune complex lattice on the C1q solid phase assay as determined with covalently cross-linked immune complexes.
    Wener MH; Mannik M
    Clin Exp Immunol; 1983 Jun; 52(3):543-50. PubMed ID: 6603296
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Use of the C1q binding assay in the analysis of immune complexes: personal experiences with its clinical use and future prospectives].
    Corvetta A; Spaeth PJ; Panico F; Ghirelli PA; Orecchioni F; Danieli G
    G Clin Med; 1983; 64(9-10):337-48. PubMed ID: 6198235
    [No Abstract]   [Full Text] [Related]  

  • 18. An enzymatically active antigen-antibody probe to measure circulating immune complexes. II. E. coli beta-galactosidase in the probe and C1q as the recognition unit.
    Migliorini P; Trovatello G; Cantarella S; Manca F; Bombardieri S; Celada F
    J Immunol Methods; 1983 Apr; 59(2):245-54. PubMed ID: 6404986
    [TBL] [Abstract][Full Text] [Related]  

  • 19. C1q solid-phase radioimmunoassay: binding properties of solid-phase C1q and evidence that C1q-binding IgG complexes in systemic lupus erythematosus are not bound to endogenous C1q.
    Uwatoko S; Aotsuka S; Okawa M; Egusa Y; Yokohari R; Aizawa C; Suzuki K
    J Immunol Methods; 1984 Oct; 73(1):67-74. PubMed ID: 6436382
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assay, purification and further characterization of 7S C1q-precipitins (C1q-p) in hypocomplementemic vasculitis urticaria syndrome and systemic lupus erythematosus.
    Marder RJ; Potempa LA; Jones JV; Toriumi D; Schmid FR; Gewurz H
    Acta Pathol Microbiol Immunol Scand Suppl; 1984; 284():25-34. PubMed ID: 6375256
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.