BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 6343447)

  • 1. Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method.
    Ibañez J; Raurich JM; Moris SG
    Intensive Care Med; 1983; 9(2):91-3. PubMed ID: 6343447
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Modification of the open circuit N2 washout technique for measurement of functional residual capacity in premature infants.
    Hentschel R; Suska A; Volbracht A; Brune T; Jorch G
    Pediatr Pulmonol; 1997 Jun; 23(6):434-41. PubMed ID: 9220526
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of a nitrogen washout system to measure functional residual capacity in premature infants with hyaline membrane disease.
    Miller J; Law AB; Parker RA; Sundell HW; Lindstrom DP; Cotton RB
    Pediatr Pulmonol; 1995 Dec; 20(6):403-9. PubMed ID: 8649921
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation.
    Ibañez J; Raurich JM; Moris SG
    Crit Care Med; 1982 May; 10(5):332-4. PubMed ID: 7042202
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of an acoustic helium analyzer and microprocessor for rapid measurement of absolute lung volume during mechanical ventilation.
    Gillespie DJ
    Crit Care Med; 1985 Feb; 13(2):118-21. PubMed ID: 3967501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.
    Brewer L; Orr J; Fulcher E; Markewitz B
    J Clin Monit Comput; 2011 Dec; 25(6):397-404. PubMed ID: 22057246
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated measurement of functional residual capacity by sulfur hexafluoride washout.
    East TD; Andriano KP; Pace NL
    J Clin Monit; 1987 Jan; 3(1):14-21. PubMed ID: 3546608
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Functional residual capacity (FRC) and lung clearance index (LCI) in mechanically ventilated infants: application in the newborn with congenital diaphragmatic hernia (CDH).
    Landolfo F; Savignoni F; Capolupo I; Columbo C; Calzolari F; Giliberti P; Chukhlantseva N; Bagolan P; Dotta A
    J Pediatr Surg; 2013 Jul; 48(7):1459-62. PubMed ID: 23895954
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated sulfur hexafluoride washout functional residual capacity measurement system for any mode of mechanical ventilation as well as spontaneous respiration.
    East TD; Wortelboer PJ; van Ark E; Bloem FH; Peng L; Pace NL; Crapo RO; Drews D; Clemmer TP
    Crit Care Med; 1990 Jan; 18(1):84-91. PubMed ID: 2293972
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A practical procedure for measuring functional residual capacity during mechanical ventilation with or without PEEP.
    Weaver LJ; Pierson DJ; Kellie R; Bonner B; Craig KC
    Crit Care Med; 1981 Dec; 9(12):873-7. PubMed ID: 7032846
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The accuracy of the oxygen washout technique for functional residual capacity assessment during spontaneous breathing.
    Heinze H; Schaaf B; Grefer J; Klotz K; Eichler W
    Anesth Analg; 2007 Mar; 104(3):598-604. PubMed ID: 17312216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of functional residual capacity by modified multiple breath nitrogen washout for spontaneously breathing and mechanically ventilated patients.
    Brewer LM; Orr JA; Sherman MR; Fulcher EH; Markewitz BA
    Br J Anaesth; 2011 Nov; 107(5):796-805. PubMed ID: 21752798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Measurement of functional residual capacity by nitrogen washout during mechanical ventilation].
    Nomura T; Saito Y; Ogawa H; Akata N; Nishino Y; Kosaka Y
    Masui; 1998 Feb; 47(2):174-9. PubMed ID: 9513330
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of helium dilution and nitrogen washout measurements of functional residual capacity in infants and very young children.
    Tepper RS; Asdell S
    Pediatr Pulmonol; 1992 Aug; 13(4):250-4. PubMed ID: 1523037
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Functional residual capacity and ventilation homogeneity in mechanically ventilated small neonates.
    Vilstrup CT; Björklund LJ; Larsson A; Lachmann B; Werner O
    J Appl Physiol (1985); 1992 Jul; 73(1):276-83. PubMed ID: 1506381
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of functional residual capacity by helium dilution during partial support ventilation: in vitro accuracy and in vivo precision of the method.
    Di Marco F; Rota Sperti L; Milan B; Stucchi R; Centanni S; Brochard L; Fumagalli R
    Intensive Care Med; 2007 Dec; 33(12):2109-15. PubMed ID: 17703280
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Functional residual capacity during anaesthesia. I: Methodology.
    Hewlett AM; Hulands GH; Nunn JF; Minty KB
    Br J Anaesth; 1974 Jul; 46(7):479-85. PubMed ID: 4617586
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simplified method to determine functional residual capacity during mechanical ventilation.
    Heldt GP; Peters RM
    Chest; 1978 Nov; 74(5):492-6. PubMed ID: 738086
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of functional residual capacity during mechanical ventilation for acute respiratory failure. A comparison between closed and an open-circuit helium dilution technique.
    Hylkema BS; Barkmeijer-Degenhart P; van der Mark TW; Peset R; Sluiter HJ
    Chest; 1982 Jan; 81(1):27-30. PubMed ID: 7053937
    [No Abstract]   [Full Text] [Related]  

  • 20. Measurement of functional residual capacity and pulmonary carbon monoxide diffusing capacity during mechanical ventilation with PEEP.
    Kondo T; Kurata T; Takasaki Y; Ohta Y; Yamabayashi H
    Tokai J Exp Clin Med; 1982 Sep; 7(5):561-73. PubMed ID: 6763783
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.