These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Comparison of bioassay, high-performance liquid chromatography, and fluorescence polarization immunoassay for quantitative determination of vancomycin in serum. Ristuccia PA; Ristuccia AM; Bidanset JH; Cunha BA Ther Drug Monit; 1984; 6(2):238-42. PubMed ID: 6377600 [TBL] [Abstract][Full Text] [Related]
4. Automated fluorescence polarization immunoassay for monitoring vancomycin. Schwenzer KS; Wang CH; Anhalt JP Ther Drug Monit; 1983; 5(3):341-5. PubMed ID: 6636261 [TBL] [Abstract][Full Text] [Related]
5. Determination of vancomycin in human serum by high-pressure liquid chromatography. Jehl F; Gallion C; Thierry RC; Monteil H Antimicrob Agents Chemother; 1985 Apr; 27(4):503-7. PubMed ID: 3890726 [TBL] [Abstract][Full Text] [Related]
6. Comparison of fluorescence polarization immunoassay and bioassay of vancomycin. Pohlod DJ; Saravolatz LD; Somerville MM J Clin Microbiol; 1984 Aug; 20(2):159-61. PubMed ID: 6436291 [TBL] [Abstract][Full Text] [Related]
7. Vancomycin monitoring in term newborns: comparison of peak and trough serum concentrations determined by high performance liquid chromatography and fluorescence polarization immunoassay. Feferbaum R; Kobol Machado JK; de Albuquerque Diniz EM; Okay TS; Santos SR; Ceccon ME; Krebs VL; de Araújo MC; Costa Vaz A Rev Hosp Clin Fac Med Sao Paulo; 2001; 56(5):149-52. PubMed ID: 11781595 [TBL] [Abstract][Full Text] [Related]
8. Overestimation of vancomycin concentrations utilizing fluorescence polarization immunoassay in patients on peritoneal dialysis. Morse GD; Nairn DK; Bertino JS; Walshe JJ Ther Drug Monit; 1987 Jun; 9(2):212-5. PubMed ID: 3617161 [TBL] [Abstract][Full Text] [Related]
9. [HPLC, RIA, FPIA. Evaluation of 3 methods for the assay of vancomycin]. Jehl F; Monteil H; Gallion C; Thierry RC Pathol Biol (Paris); 1985 Jun; 33(5 Pt 2):511-6. PubMed ID: 3911145 [TBL] [Abstract][Full Text] [Related]
11. Measurement of vancomycin in renally impaired patient samples using a new high-performance liquid chromatography method with vitamin B12 internal standard: comparison of high-performance liquid chromatography, emit, and fluorescence polarization immunoassay methods. Hu MW; Anne L; Forni T; Gottwald K Ther Drug Monit; 1990 Nov; 12(6):562-9. PubMed ID: 2275003 [TBL] [Abstract][Full Text] [Related]
12. Comparison of the fluorescence polarization immunoassay and the microbiological assay methods for the determination of gentamicin concentration in human serum. Tayeb OS; el-Tahawy AT; Islam SI Ther Drug Monit; 1986; 8(2):232-5. PubMed ID: 3726941 [TBL] [Abstract][Full Text] [Related]
13. Potential problem with fluorescence polarization immunoassay cross-reactivity to vancomycin degradation product CDP-1: its detection in sera of renally impaired patients. Anne L; Hu M; Chan K; Colin L; Gottwald K Ther Drug Monit; 1989 Sep; 11(5):585-91. PubMed ID: 2683253 [TBL] [Abstract][Full Text] [Related]
14. Competitive immunoassay for vancomycin using capillary electrophoresis with laser-induced fluorescence detection. Lam MT; Le Chris X Analyst; 2002 Dec; 127(12):1633-7. PubMed ID: 12537372 [TBL] [Abstract][Full Text] [Related]
15. New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease. Smith PF; Petros WP; Soucie MP; Copeland KR Ther Drug Monit; 1998 Apr; 20(2):231-5. PubMed ID: 9558140 [TBL] [Abstract][Full Text] [Related]
16. An improved micromethod for vancomycin determination by high-performance liquid chromatography. Li L; Miles MV; Hall W; Carson SW Ther Drug Monit; 1995 Aug; 17(4):366-70. PubMed ID: 7482691 [TBL] [Abstract][Full Text] [Related]
17. Rapid serum vancomycin assay by high-performance liquid chromatography using a semipermeable surface packing material column. Furuta I; Kitahashi T; Kuroda T; Nishio H; Oka C; Morishima Y Clin Chim Acta; 2000 Nov; 301(1-2):31-9. PubMed ID: 11020460 [TBL] [Abstract][Full Text] [Related]
18. Instability of standard calibrators may be involved in overestimating vancomycin concentrations determined by fluorescence polarization immunoassay. Morishige H; Shuto H; Ieiri I; Otsubo K; Oishi R Ther Drug Monit; 1996 Feb; 18(1):80-5. PubMed ID: 8848826 [TBL] [Abstract][Full Text] [Related]
19. Abbott AxSYM Vancomycin II assay: multicenter evaluation and interference studies. Azzazy HM; Chou PP; Tsushima JH; Troxil S; Gordon M; Avers RJ; Chiappetta E; Duh SH; Christenson RH Ther Drug Monit; 1998 Apr; 20(2):202-8. PubMed ID: 9558135 [TBL] [Abstract][Full Text] [Related]
20. Performance of a fluorescence polarization immunoassay for teicoplanin in serum. Mastin SH; Buck RL; Mueggler PA Diagn Microbiol Infect Dis; 1993 Jan; 16(1):17-24. PubMed ID: 8425374 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]