These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 6372530)

  • 1. Avoidance of artifacts on computerized tomograms by selection of appropriate surgical clips.
    Weese JL; Rosenthal MS; Gould H
    Am J Surg; 1984 May; 147(5):684-7. PubMed ID: 6372530
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The problem of metal clip artefacts in computerized tomography].
    Vock P; Aeberhard P; Schneekloth G
    Schweiz Med Wochenschr; 1982 Apr; 112(16):561-7. PubMed ID: 7079695
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computed tomographic evaluation of surgical clip artifact: tissue phantom and experimental animal assessment.
    Silverman PM; Spicer LD; McKinney R; Feldman DB
    Comput Radiol; 1986; 10(1):37-40. PubMed ID: 3956187
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Black hole artifacts-a new potential pitfall for DXA accuracy?
    Morgan SL; Lopez-Ben R; Nunnally N; Burroughs L; Fineberg N; Tubbs RS; Yester MV
    J Clin Densitom; 2008; 11(2):266-75. PubMed ID: 18291695
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic field effects on surgical ligation clips.
    Brown MA; Carden JA; Coleman RE; McKinney R; Spicer LD
    Magn Reson Imaging; 1987; 5(6):443-53. PubMed ID: 3431354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Surgical ligation clip artifacts on CT scans.
    Gross SC; Kowalski JB; Lee SH; Terry B; Honickman SJ
    Radiology; 1985 Sep; 156(3):831-2. PubMed ID: 4023253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of magnetic resonance and computed tomographic image quality after the implantation of tantalum and titanium spinal instrumentation.
    Wang JC; Yu WD; Sandhu HS; Tam V; Delamarter RB
    Spine (Phila Pa 1976); 1998 Aug; 23(15):1684-8. PubMed ID: 9704376
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine.
    Levi AD; Choi WG; Keller PJ; Heiserman JE; Sonntag VK; Dickman CA
    Spine (Phila Pa 1976); 1998 Jun; 23(11):1245-50; discussion 1251. PubMed ID: 9636978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiologic advantages of potential use of polymer plastic clips in neurosurgery.
    Delibegović S
    World Neurosurg; 2014; 81(3-4):549-51. PubMed ID: 24067738
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aneurysm clip MR artifacts. Titanium versus stainless steel and influence of imaging parameters.
    Burtscher IM; Owman T; Romner B; Ståhlberg F; Holtås S
    Acta Radiol; 1998 Jan; 39(1):70-6. PubMed ID: 9498874
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification.
    Thomas CW; Nichol AM; Park JE; Hui JF; Giddings AA; Grahame S; Otto K
    Radiother Oncol; 2009 Jan; 90(1):56-9. PubMed ID: 18417232
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of magnetic and radiographic imaging artifact after using three types of metal rods: stainless steel, titanium, and vitallium.
    Knott PT; Mardjetko SM; Kim RH; Cotter TM; Dunn MM; Patel ST; Spencer MJ; Wilson AS; Tager DS
    Spine J; 2010 Sep; 10(9):789-94. PubMed ID: 20619749
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Metallic Artifacts Caused by Nonpenetrating Titanium Clips in Postoperative Neuroimaging.
    Ito K; Seguchi T; Nakamura T; Chiba A; Hasegawa T; Nagm A; Horiuchi T; Hongo K
    World Neurosurg; 2016 Dec; 96():16-22. PubMed ID: 27586178
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multidetector computed tomographic characteristics of nonabsorbable polymer versus titanium ligature clips in a vascular model.
    Foster G; Plunkett M; Wagner A; Abraham S; Baldwin D; Hill B; Kim H
    J Thorac Cardiovasc Surg; 2008 Nov; 136(5):1324-7. PubMed ID: 19026823
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Metal-induced artifacts in computed tomography and magnetic resonance imaging: comparison of a biodegradable magnesium alloy versus titanium and stainless steel controls.
    Filli L; Luechinger R; Frauenfelder T; Beck S; Guggenberger R; Farshad-Amacker N; Andreisek G
    Skeletal Radiol; 2015 Jun; 44(6):849-56. PubMed ID: 25417003
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metallic clips as a time/cost saving adjunct to head and neck surgery.
    Davidson TM; Olson TS
    Head Neck; 1990; 12(6):500-2. PubMed ID: 2258289
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.
    Delibegovic S; Dizdarevic K; Cickusic E; Katica M; Obhodjas M; Ocus M
    Turk Neurosurg; 2016; 26(6):866-870. PubMed ID: 27560530
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of common orthodontic appliances on the diagnostic quality of cranial magnetic resonance images.
    Elison JM; Leggitt VL; Thomson M; Oyoyo U; Wycliffe ND
    Am J Orthod Dentofacial Orthop; 2008 Oct; 134(4):563-72. PubMed ID: 18929275
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of titanium and absorbable polymeric surgical clips for use in laparoscopic cholecystectomy.
    Klein RD; Jessup G; Ahari F; Connolly RJ; Schwaitzberg SD
    Surg Endosc; 1994 Jul; 8(7):753-8. PubMed ID: 7974100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning.
    Sullivan PK; Smith JF; Rozzelle AA
    Plast Reconstr Surg; 1994 Oct; 94(5):589-96. PubMed ID: 7938281
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.