These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 6374362)

  • 1. [Unit for studying parameters in the process of bone cutting].
    Zelenov ES; Repin VA
    Med Tekh; 1984; (2):50-1. PubMed ID: 6374362
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.
    Ercoli C; Funkenbusch PD; Lee HJ; Moss ME; Graser GN
    Int J Oral Maxillofac Implants; 2004; 19(3):335-49. PubMed ID: 15214217
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography.
    Watanabe F; Tawada Y; Komatsu S; Hata Y
    Int J Oral Maxillofac Implants; 1992; 7(2):212-9. PubMed ID: 1398838
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites.
    Brisman DL
    Int J Oral Maxillofac Implants; 1996; 11(1):35-7. PubMed ID: 8820120
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production.
    Iyer S; Weiss C; Mehta A
    Int J Prosthodont; 1997; 10(5):411-4. PubMed ID: 9495159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing.
    Iyer S; Weiss C; Mehta A
    Int J Prosthodont; 1997; 10(6):536-40. PubMed ID: 9495174
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of ultrasonic devices for bone surgery and associated intraosseous temperature development.
    Harder S; Wolfart S; Mehl C; Kern M
    Int J Oral Maxillofac Implants; 2009; 24(3):484-90. PubMed ID: 19587871
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new computerized control unit for small bone surgical instruments.
    Neal JG; Cox MJ; Drake DB; Hoard MA; Thacker JG; Watkins FH; Edlich RF
    Med Prog Technol; 1997; 21 Suppl():25-9. PubMed ID: 9413825
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Investigations on the shape and size of bone-chips produced during boring and grinding (author's transl)].
    Paulsen K
    Laryngol Rhinol Otol (Stuttg); 1975 Oct; 54(10):835-40. PubMed ID: 129601
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparative studies on heat development with internally and conventionally cooled bone drills and milling cutters].
    Bolz U; Kalweit K
    Dtsch Zahnarztl Z; 1976 Dec; 31(12):959. PubMed ID: 793836
    [No Abstract]   [Full Text] [Related]  

  • 11. [Study and development of angular tips for dental handpieces].
    Kanaev VF; Repin VA
    Med Tekh; 1983; (2):14-9. PubMed ID: 6343753
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Studies on the performance of the dental air turbine handpieces. (Part 5) Rotational performance of various kinds of dental air turbine handpieces (N = N0--CvFv gamma) (author's transl)].
    Miyairi H; Nagai M; Fukuda H; Muramatsu A
    Shika Rikogaku Zasshi; 1981 Oct; 22(60):262-70. PubMed ID: 7037999
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Heat production by 3 implant drill systems after repeated drilling and sterilization.
    Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM
    J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro comparison of the cutting efficiency and temperature production of ten different rotary cutting instruments. Part II: electric handpiece and comparison with turbine.
    Ercoli C; Rotella M; Funkenbusch PD; Russell S; Feng C
    J Prosthet Dent; 2009 May; 101(5):319-31. PubMed ID: 19410066
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Ultrasonic resection of bones and soft tissues in reconstructive surgery].
    Poliakov VA; Volkov MV
    Vestn Khir Im I I Grek; 1971 Apr; 106(4):71-4. PubMed ID: 5565384
    [No Abstract]   [Full Text] [Related]  

  • 16. Investigation of variable factors in drilling bone.
    Hobkirk JA; Rusiniak K
    J Oral Surg; 1977 Dec; 35(12):968-73. PubMed ID: 336854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ceramic implant abutments: cutting efficiency and resultant surface finish by diamond rotary cutting instruments.
    Park SW; Driscoll CF; Romberg EE; Siegel S; Thompson G
    J Prosthet Dent; 2006 Jun; 95(6):444-9. PubMed ID: 16765157
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [New equipment for cutting test of rotary cutting instruments (author's transl)].
    Fukuda H; Miyairi H; Nagai M; Kobayashi M; Muramatsu A
    Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1980; 14():13-7. PubMed ID: 7016135
    [No Abstract]   [Full Text] [Related]  

  • 19. [Experiences with a new bone drill for surgery of the ear and nose (author's transl)].
    Paulsen K
    HNO; 1976 Nov; 24(11):409-10. PubMed ID: 993085
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The rotational performance of dental high-speed handpieces].
    Fukuda H; Nagai M; Kobayashi M; Miyairi H; Muramatsu A
    Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1981; 15():61-8. PubMed ID: 7051207
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.