These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 6379003)

  • 1. The influence of sprue design on cobalt chromium alloy casting defects.
    Matin KA; Manderson RD
    J Dent; 1984 Jun; 12(2):175-82. PubMed ID: 6379003
    [No Abstract]   [Full Text] [Related]  

  • 2. Sprue design in removable partial denture casting.
    Burnett CA; Maguire H
    J Dent; 1996; 24(1-2):99-103. PubMed ID: 8636502
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The evaluation of factors affecting the castability of metal ceramic alloy--investment combinations.
    Johnson A; Winstanley RB
    Int J Prosthodont; 1996; 9(1):74-8. PubMed ID: 8630180
    [TBL] [Abstract][Full Text] [Related]  

  • 4. THE PRECISION CASTING OF COBALT-CHROMIUM ALLOY. 1. THE INFLUENCE OF CASTING VARIABLES ON DIMENSIONS AND FINISH.
    CARTER TJ; KIDD JN
    Br Dent J; 1965 May; 118():383-90. PubMed ID: 14289045
    [No Abstract]   [Full Text] [Related]  

  • 5. Analysis of four dental alloys following torch/centrifugal and induction/ vacuum-pressure casting procedures.
    Thompson GA; Luo Q; Hefti A
    J Prosthet Dent; 2013 Dec; 110(6):471-80. PubMed ID: 24120072
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sprue design and its effect on the castability of ceramometal alloys.
    Young HM; Coffey JP; Caswell CW
    J Prosthet Dent; 1987 Feb; 57(2):160-4. PubMed ID: 3550050
    [No Abstract]   [Full Text] [Related]  

  • 7. Casting defects in subperiosteal implants: an x-ray investigation.
    Hargraves J; Hobkirk JA
    J Dent; 1982 Mar; 10(1):1-6. PubMed ID: 7045176
    [No Abstract]   [Full Text] [Related]  

  • 8. Effects of sprue design, casting machine, and heat source on casting porosity.
    Compagni R; Faucher RR; Yuodelis RA
    J Prosthet Dent; 1984 Jul; 52(1):41-5. PubMed ID: 6379164
    [No Abstract]   [Full Text] [Related]  

  • 9. Comparison of titanium and cobalt-chromium removable partial denture clasps.
    Bridgeman JT; Marker VA; Hummel SK; Benson BW; Pace LL
    J Prosthet Dent; 1997 Aug; 78(2):187-93. PubMed ID: 9260137
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The application of nickel-chromium dental alloys to small casting restorations].
    Murasawa H
    Tsurumi Shigaku; 1983 Jan; 9(1):115-30. PubMed ID: 6338637
    [No Abstract]   [Full Text] [Related]  

  • 11. Effect of vacuum and supertemperature on mold filling during casting.
    Herö H; Waarli M
    Scand J Dent Res; 1991 Feb; 99(1):55-9. PubMed ID: 2047754
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Training dental technicians. 23. Chromium-cobalt-molybdenum castings of polished cast prostheses. 1. Embedding & pouring].
    Caesar HH
    Dent Labor (Munch); 1984 Sep; 32(9):1011-8. PubMed ID: 6389197
    [No Abstract]   [Full Text] [Related]  

  • 13. [Casting precision of fixed prostheses in the laboratory. 2. Treatment of investing materials].
    Chan Thu A; Ollier J; Samama Y
    Cah Prothese; 1982 Oct; 10(40):73-88. PubMed ID: 6764881
    [No Abstract]   [Full Text] [Related]  

  • 14. Effect of electric arc, gas oxygen torch and induction melting techniques on the marginal accuracy of cast base-metal and noble metal-ceramic crowns.
    Gómez-Cogolludo P; Castillo-Oyagüe R; Lynch CD; Suárez-García MJ
    J Dent; 2013 Sep; 41(9):826-31. PubMed ID: 23810734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New improvement of the melting and casting machine for cobalt-chromium casting alloy using the vacuum method.
    Fukui H; Nishi T; Shinoda M; Sawada T; Hasegawa J
    Aichi Gakuin Daigaku Shigakkai Shi; 1974 Mar; 11(4):321-9. PubMed ID: 4616631
    [No Abstract]   [Full Text] [Related]  

  • 16. Use of plastic bar molded casting in the modification of variably expanding investment to compensate for casting shrinkage of nickel-chromium alloy.
    Shigeto N; Iwanaga H; Hamada T
    J Prosthet Dent; 1992 Sep; 68(3):468-70. PubMed ID: 1432763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Studies on the castability of Co-Cr alloy for cast plates. Part 1: The effects of sprue attachment direction to wax plates and the investment direction of refractory models.
    Satoh Y; Toyoma H; Ohki K; Kimura K; Shina Y; Maeda K
    J Nihon Univ Sch Dent; 1989 Mar; 31(1):397-407. PubMed ID: 2659748
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of alloy composition and casting procedure upon the corrosion behaviour of dental alloys: an in vitro study.
    Mülders C; Darwish M; Holze R
    J Oral Rehabil; 1996 Dec; 23(12):825-31. PubMed ID: 8971644
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation and comparison of castability between an indigenous and imported Ni-Cr alloy.
    Ramesh G; Padmanabhan TV; Ariga P; Subramanian R
    Indian J Dent Res; 2011; 22(5):733. PubMed ID: 22406728
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Evaluation of casting precision of different nickel-chromium alloys intended for the construction of partial dentures].
    Lubespere R; Meyer JM; Lubespere A
    Bull Group Int Rech Sci Stomatol Odontol; 1984 Jan; 27(1):31-51. PubMed ID: 6372906
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.