These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 6386231)

  • 21. Automated latex nephelometric immunoassay of theophylline in human serum.
    Borque L; Rus A; Maside C; del Cura J
    Eur J Clin Chem Clin Biochem; 1992 May; 30(5):307-9. PubMed ID: 1627729
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Serum theophylline assay by rate nephelometric inhibition immunoassay: a comparison with high-performance liquid chromatography.
    Samoszuk M; Kaplan E; Finkle HI
    Ther Drug Monit; 1983; 5(1):113-6. PubMed ID: 6342212
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical application of the Biotrack 516 system for determination of theophylline by a turbidimetric latex agglutination inhibition reaction.
    Tsunekawa Y; Hasegawa T; Nadai M; Yamaki K; Takagi K; Nabeshima T
    Ther Drug Monit; 1996 Feb; 18(1):86-91. PubMed ID: 8848827
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determination of serum theophylline by apoenzyme reactivation immunoassay system.
    Plebani M; Burlina A
    Ther Drug Monit; 1985; 7(4):451-4. PubMed ID: 3909537
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer.
    Thakkar H; Newman DJ; Holownia P; Davey CL; Wang CC; Lloyd J; Craig AR; Price CP
    Clin Chem; 1997 Jan; 43(1):109-13. PubMed ID: 8990231
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of mycophenolic acid concentrations determined by a new PETINIA assay on the dimension EXL analyzer and a HPLC-UV method.
    Dasgupta A; Tso G; Chow L
    Clin Biochem; 2013 May; 46(7-8):685-7. PubMed ID: 23219740
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A Comparison of the Immunochemical Methods, PETINIA and EMIT, With That of HPLC-UV for the Routine Monitoring of Mycophenolic Acid in Heart Transplant Patients.
    Kunicki PK; Pawiński T; Boczek A; Waś J; Bodnar-Broniarczyk M
    Ther Drug Monit; 2015 Jun; 37(3):311-8. PubMed ID: 25380305
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Determination of adiponectin in serum using a latex particle-enhanced turbidimetric immunoassay with an automated analyzer.
    Nishimura A; Sawai T
    Clin Chim Acta; 2006 Sep; 371(1-2):163-8. PubMed ID: 16712824
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparability of a new turbidimetric digoxin test with other immunochemical tests and with HPLC--a multicenter evaluation.
    Scholer A; Boecker J; Engelmayer U; Feldmann K; Hannak D; Kattermann R; Oellerich M; Raith H; Schlebusch H; Wieland H; Willems D; Jarausch J; Domke I
    Clin Chem; 1997 Jan; 43(1):92-9. PubMed ID: 8990228
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy and precision of gas-liquid chromatographic, high-pressure liquid chromatographic, and enzyme immunoassay techniques for the measurement of theophylline concentrations in serum: a comparison based on external quality assurance measurements.
    Wilson JF; Marshall RW; Williams J; Richens A
    Ther Drug Monit; 1984; 6(2):243-50. PubMed ID: 6377601
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Possible false-negative results on therapeutic drug monitoring of phenytoin using a particle enhanced turbidimetric inhibition immunoassay in a patient with a high level of IgM.
    Hirata K; Saruwatari J; Enoki Y; Iwata K; Urata Y; Aizawa K; Ueda K; Shirouzono T; Imamura M; Moriuchi H; Ishima Y; Kadowaki D; Watanabe H; Hirata S; Maruyama T; Fukunaga E
    Ther Drug Monit; 2014 Oct; 36(5):553-5. PubMed ID: 24632808
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A clinical trial for therapeutic drug monitoring using microchip-based fluorescence polarization immunoassay.
    Tachi T; Hase T; Okamoto Y; Kaji N; Arima T; Matsumoto H; Kondo M; Tokeshi M; Hasegawa Y; Baba Y
    Anal Bioanal Chem; 2011 Oct; 401(7):2301-5. PubMed ID: 21837465
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An evaluation of immunoglobulin assays on the ACA III.
    Rammeloo T; Beunis MH
    J Clin Chem Clin Biochem; 1983 Sep; 21(9):577-82. PubMed ID: 6415213
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Quantitative determination of theophylline by an automated chemiluminescent immunoassay in serum and plasma: comparison to other methods of analysis.
    Malliaros DP; Wong SS; Wu AH; Campbell J; Leonard H; Houser S; Berg M; Gornet T; Brown C; Feng YJ
    Ther Drug Monit; 1997 Apr; 19(2):224-9. PubMed ID: 9108655
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of a particle-enhanced turbidimetric immunoassay for the measurement of immunoglobulin E in an ILab 900 analyzer.
    Guaita S; Simó JM; Ferré N; Joven J; Camps J
    Clin Chem; 1999 Sep; 45(9):1557-61. PubMed ID: 10471661
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of the Abbott TDx for the stat measurement of phenobarbital, phenytoin, carbamazepine, and theophylline.
    Loomis KF; Frye RM
    Am J Clin Pathol; 1983 Nov; 80(5):686-91. PubMed ID: 6637881
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of theophylline in serum with the Seralyzer Aris reagent strip test evaluated.
    Lindberg R; Ivaska K; Irjala K; Vanto T
    Clin Chem; 1985 Apr; 31(4):613-4. PubMed ID: 3884181
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Patient-side immunoassay system with a single-use cartridge for measuring analytes in blood.
    Gibbons I; Gorin M; Yassinzadeh Z; Peterson P; Besemer D; Dillon K; Burd T; Hillman R; Smoluk G; Cobb M
    Clin Chem; 1989 Sep; 35(9):1869-73. PubMed ID: 2776311
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Assay of theophylline: in vivo and in vitro evaluation of dry chemistry and immunoassay versus high-performance liquid chromatography.
    Wallinder H; Gustafsson LL; Angbäck K; Höglund P; Magnusson A; Arvanius L
    Ther Drug Monit; 1991 May; 13(3):233-9. PubMed ID: 1926277
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A fluorescent immunoassay for theophylline: description and comparison to enzyme immunoassay, liquid chromatography and radioimmunoassay.
    Castro A; Steele B
    Clin Biochem; 1983 Oct; 16(5):281-4. PubMed ID: 6360416
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.