These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 6396386)

  • 1. Interrupted and continuous microarteriorrhaphy techniques: a hemodynamic comparison.
    Blair WF; Pedersen DR; Joos K; Bondi D
    J Orthop Res; 1984; 2(4):419-24. PubMed ID: 6396386
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microarteriorrhaphy: blood flow after wound healing.
    Blair WF; Pedersen DR; Joos K; Green ER; Bondi D
    Microsurgery; 1985; 6(2):116-20. PubMed ID: 3160910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A hemodynamic evaluation of cuffed microarteriorrhaphy.
    Bell LD; Blair WF; Pedersen DR; Gabel RH
    Microsurgery; 1985; 6(2):106-12. PubMed ID: 3160909
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulsed ultrasound Doppler velocimetry in the assessment of microvascular hemodynamics.
    Blair WF; Brown TD; Greene ER
    J Orthop Res; 1988; 6(2):300-9. PubMed ID: 2963897
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of continuous and interrupted suture techniques in microvascular anastomosis.
    Lee BY; Thoden WR; Brancato RF; Kavner D; Shaw W; Madden JL
    Surg Gynecol Obstet; 1982 Sep; 155(3):353-7. PubMed ID: 7051380
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A histologic comparison of continuous and interrupted microarteriorrhaphy.
    Joos KM; Blair WF; Maynard JA
    Microsurgery; 1985; 6(3):141-6. PubMed ID: 3903426
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of continuous and interrupted suture techniques in microvascular anastomosis.
    Chen YX; Chen LE; Seaber AV; Urbaniak JR
    J Hand Surg Am; 2001 May; 26(3):530-9. PubMed ID: 11418920
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of continuous horizontal mattress suture techniques in microsurgery: an experimental study in rats.
    Tetik C; Unal MB; Kocaoglu B; Erol B
    J Hand Surg Am; 2005 May; 30(3):587-95. PubMed ID: 15925172
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous versus interrupted suture technique in microvascular anastomosis in rats.
    Barros RSM; Leal RA; Teixeira RKC; Yamaki VN; Feijó DH; Gouveia EHH; Valente AL; Silva DJ; Carvalho LTF
    Acta Cir Bras; 2017 Sep; 32(9):691-696. PubMed ID: 29019586
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of continuous and interrupted suture techniques in microvascular end-to-side anastomosis.
    Wheatley MJ; Mathes SJ; Hassett C
    J Reconstr Microsurg; 1986 Jan; 2(2):93-6. PubMed ID: 3511253
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemodynamic comparison of microsurgical closures for longitudinal arteriotomies.
    Cipoletti RD; Moneim MS; Greene ER
    Microsurgery; 1993; 14(2):107-13. PubMed ID: 8469104
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Hemodynamic study by pulsed ultrasonic velocimetry of axillo-femoral bypass].
    Levy BI; Michel JB; Bailliart O; Lagneau P
    Arch Mal Coeur Vaiss; 1981 Aug; 74(8):979-84. PubMed ID: 6793013
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spiral interrupted suturing technique for microvascular anastomosis: a comparative study.
    Chen L; Chiu DT
    Microsurgery; 1986; 7(2):72-8. PubMed ID: 3523110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodynamics after microsurgical anastomosis: the effects of topical lidocaine.
    Blair WF; Greene ER; Eldridge M; Cipoletti R
    J Microsurg; 1981 Mar; 2(3):157-64. PubMed ID: 7241038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemodynamic comparison of microsurgical repairs for large arterial defects.
    Cipoletti RD; Moneim MS; Greene ER
    Microsurgery; 1994; 15(8):579-85. PubMed ID: 7830541
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A hemodynamic study of the effects of arterial anastomoses with interrupted simple versus horizontal mattress sutures on rat epigastric flap perfusion.
    Orak I; Güneren E; Yildiz L
    Ann Plast Surg; 2006 Jul; 57(1):84-8. PubMed ID: 16799315
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Postsurgical changes of the calculated wall shear stress in autogenous interpositional venous grafts by blood flow waveform analysis: clinical and experimental studies].
    Zhao L; Huang Y; Li J; Huang M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Mar; 14(1):21-5. PubMed ID: 9817659
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microsurgical anastomosis with the 'PCA' technique.
    Cigna E; Curinga G; Bistoni G; Spalvieri C; Tortorelli G; Scuderi N
    J Plast Reconstr Aesthet Surg; 2008 Jul; 61(7):762-6. PubMed ID: 18468969
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodynamics after autogenous, interpositional grafting in small arteries.
    Blair WF; Chang L; Pedersen DR; Gabel RH; Bell LD
    Microsurgery; 1986; 7(2):84-6. PubMed ID: 2941670
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Usefulness of combined continuous suture and interrupted tie technique in hindlimb composite tissue allotransplantation in rats.
    Ulusal BG; Ulusal AE; Hung LM; Wei FC
    Microsurgery; 2005; 25(1):80-2. PubMed ID: 15547926
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.