These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 6401364)

  • 1. A surface bolus material for high-energy photon and electron therapy.
    Moyer RF; McElroy WR; O'Brien JE; Chamberlain CC
    Radiology; 1983 Feb; 146(2):531-2. PubMed ID: 6401364
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lead as surface bolus for high-energy photon and electron therapy.
    Moyer RF; King GA; Hauser JF
    Med Phys; 1986; 13(2):263-6. PubMed ID: 3084929
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies.
    Tailor RC; Hanson WF
    Med Phys; 2002 Jul; 29(7):1464-72. PubMed ID: 12148727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electron backscatter corrections for parallel-plate chambers.
    Hunt MA; Kutcher GJ; Buffa A
    Med Phys; 1988; 15(1):96-103. PubMed ID: 3127670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of IAEA 1987 and AAPM 1983 protocols for dosimetry calibration of radiotherapy beams.
    Huq MS; Nath R
    Med Phys; 1991; 18(1):26-35. PubMed ID: 1901129
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relative doses to skin and superficial nodes from 10 MV photons as a function of field size and distance from shadow tray.
    Bassano D
    Radiology; 1975 Jun; 115(3):707-10. PubMed ID: 805462
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calibration of high-energy photon and electron beams for radiotherapy using AAPM 1983 and IAEA 1987 dosimetry protocols.
    Huq MS; Agostinelli AG; Nath R
    Med Phys; 1993; 20(2 Pt 1):293-8. PubMed ID: 8497213
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Examination of Jeltrate Plus as a tissue equivalent bolus material.
    Babic S; Kerr AT; Westerland M; Gooding J; Schreiner LJ
    J Appl Clin Med Phys; 2002; 3(3):170-5. PubMed ID: 12132938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.
    Yukihara EG; Mardirossian G; Mirzasadeghi M; Guduru S; Ahmad S
    Med Phys; 2008 Jan; 35(1):260-9. PubMed ID: 18293581
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electron and photon beams from a 50 MeV racetrack microtron.
    Brahme A; Kraepelien T; Svensson H
    Acta Radiol Oncol; 1980; 19(4):305-19. PubMed ID: 6257054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.
    Chow JC; Jiang R
    Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Study of elasto-gel pads used as surface bolus material in high energy photon and electron therapy.
    Chang F; Chang P; Benson K; Share F
    Int J Radiat Oncol Biol Phys; 1992; 22(1):191-3. PubMed ID: 1727117
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Moldable tissue equivalent bolus for high-energy photon and electron therapy.
    Dubois D; Bice W; Bradford B; Schneid T; Engelmeier R
    Med Phys; 1996 Sep; 23(9):1547-9. PubMed ID: 8892252
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Contamination of a 15-MV photon beam by electrons and scattered photons.
    Mackie TR; Scrimger JW
    Radiology; 1982 Jul; 144(2):403-9. PubMed ID: 6806853
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of two water-equivalent phantom materials for output calibration of photon and electron beams.
    Liu L; Prasad SC; Bassano DA
    Med Dosim; 2003; 28(4):267-9. PubMed ID: 14684192
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of Water-Clear Polymeric Gels for Use as Radiotherapy Bolus.
    Adamson JD; Cooney T; Demehri F; Stalnecker A; Georgas D; Yin FF; Kirkpatrick J
    Technol Cancer Res Treat; 2017 Dec; 16(6):923-929. PubMed ID: 28554255
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Water and tissue equivalence properties of biological materials for photons, electrons, protons and alpha particles in the energy region 10 keV-1 GeV: a comparative study.
    Kurudirek M
    Int J Radiat Biol; 2016 Sep; 92(9):508-20. PubMed ID: 27419342
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Relative biological efficiency of electron and photons of a 42-MeV- betatron. LD 50/30 in mice].
    Heuss K
    Strahlentherapie; 1975 Apr; 149(4):384-9. PubMed ID: 806147
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
    Saiful Huq M; Song H; Andreo P; Houser CJ
    Med Phys; 2001 Oct; 28(10):2077-87. PubMed ID: 11695769
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.