89 related articles for article (PubMed ID: 6410606)
1. [Initial experiences with the dynamic hip screw (DHS) for proximal femoral fractures in the regional hospital].
Osterwalder A; Dietschi C; Martinoli S
Z Unfallchir Versicherungsmed Berufskr; 1983; 76(2):103-9. PubMed ID: 6410606
[No Abstract] [Full Text] [Related]
2. [Initial results with the dynamic hip screw in comparison to other osteosynthesis procedures].
Poigenfürst J; Hertz H; Hofer S
Unfallchirurgie; 1983 Apr; 9(2):98-103. PubMed ID: 6857849
[TBL] [Abstract][Full Text] [Related]
3. [Comparison among three cannulated screws and dynamic hip screw combined with antirotation screw for comminut- ed fractures of femoral neck].
Hou WR; Xu MO
Zhongguo Gu Shang; 2015 Sep; 28(9):796-801. PubMed ID: 26647559
[TBL] [Abstract][Full Text] [Related]
4. [Osteosynthesis of femoral neck fractures with the dynamic hip screw (DHS)].
Sulmoni M; Martinoli S
Helv Chir Acta; 1987 Dec; 54(4):435-41. PubMed ID: 3446635
[No Abstract] [Full Text] [Related]
5. [Development of aneurysma spurium of the arteria profunda femoris as a late complication of DHS osteosynthesis].
Kleintz R; Nolte U
Unfallchirurg; 1993 Jan; 96(1):39-40. PubMed ID: 8438172
[TBL] [Abstract][Full Text] [Related]
6. [Initial results following osteosynthesis of medial femoral neck fractures with the dynamic hip screw (DHS)].
von Flüe M; Schnyder S; Staubli A; Hildell J; Huber A; Vogt B
Helv Chir Acta; 1987 Dec; 54(4):443-6. PubMed ID: 3446636
[No Abstract] [Full Text] [Related]
7. [Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures].
Chen Z; Wang G; Lin J; Yang T; Fang Y; Liu L; Zhang H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jan; 25(1):26-9. PubMed ID: 21351604
[TBL] [Abstract][Full Text] [Related]
8. [The dynamic hip screw in fractures of the median femoral neck].
Schmidt J; Reichold HH; Kammerer V
Aktuelle Traumatol; 1991 Dec; 21(6):234-6. PubMed ID: 1685053
[TBL] [Abstract][Full Text] [Related]
9. Treatment of femoral fracture through the sliding screw portal following fixation of the femoral neck fracture.
Laohapoonrungsee A; Sirirungruangsarn Y; Apivatthakakul T; Wongtreerachtanachai P
J Med Assoc Thai; 2007 Jun; 90(6):1234-8. PubMed ID: 17624225
[TBL] [Abstract][Full Text] [Related]
10. [Osteosynthesis of the femoral neck. Comparative study of stability and clinical application. The tripod screw plate or BHP].
Faure C; Bonnel F; Oberlin P; Borgi R; Butel J
Acta Orthop Belg; 1979; 45(4):416-28. PubMed ID: 525333
[No Abstract] [Full Text] [Related]
11. Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation.
Windolf M; Braunstein V; Dutoit C; Schwieger K
Clin Biomech (Bristol, Avon); 2009 Jan; 24(1):59-64. PubMed ID: 18977058
[TBL] [Abstract][Full Text] [Related]
12. Femoral fracture following hip arthroplasty. Brief note on treatment.
Wang GJ; Miller TO; Stamp WG
J Bone Joint Surg Am; 1985 Jul; 67(6):956-8. PubMed ID: 4019544
[No Abstract] [Full Text] [Related]
13. [The dynamic hip screw in medial fractures of the femoral neck: results in 51 patients].
Bertelink BP; Stapert JW; Vierhout PA
Ned Tijdschr Geneeskd; 1993 Jan; 137(2):81-5. PubMed ID: 8421532
[TBL] [Abstract][Full Text] [Related]
14. Addition of an anti-rotation screw to the dynamic hip screw for femoral neck fractures.
Makki D; Mohamed AM; Gadiyar R; Patterson M
Orthopedics; 2013 Jul; 36(7):e865-8. PubMed ID: 23823042
[TBL] [Abstract][Full Text] [Related]
15. [The significance of plate nailing in the treatment of hip joint adjacent femoral fractures in elderly patients].
Wellner K; Bartel HG
Z Arztl Fortbild (Jena); 1982 Aug; 76(16):732-4. PubMed ID: 7148010
[No Abstract] [Full Text] [Related]
16. [The dynamic condylar screw (DCS) in proximal femoral fractures. Initial experiences].
Kahle M; David E; Filler RD; Gressner V
Unfallchirurgie; 1992 Feb; 18(1):44-7. PubMed ID: 1549887
[TBL] [Abstract][Full Text] [Related]
17. [Treatment of fractures of the proximal femur].
Mestrović N; Hirt HJ; Haffner G
Fortschr Med; 1975 Jan; 93(3):111-6. PubMed ID: 1126667
[TBL] [Abstract][Full Text] [Related]
18. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw.
Rupprecht M; Grossterlinden L; Ruecker AH; de Oliveira AN; Sellenschloh K; Nüchtern J; Püschel K; Morlock M; Rueger JM; Lehmann W
J Trauma; 2011 Sep; 71(3):625-34. PubMed ID: 21768904
[TBL] [Abstract][Full Text] [Related]
19. [Reconstructive interventions following femoral fractures].
Walter E; Holz U
Aktuelle Traumatol; 1985 Feb; 15(1):17-24. PubMed ID: 2858966
[TBL] [Abstract][Full Text] [Related]
20. [DHS osteosynthesis for proximal femoral fractures: infectious complications].
Hrubina M; Skoták M; Běhounek St J
Acta Chir Orthop Traumatol Cech; 2013; 80(5):351-5. PubMed ID: 25105677
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]