These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 641451)

  • 21. Effects of interferents on the kinetic Jaffé reaction and an enzymatic colorimetric test for serum creatinine concentration determination in cats, cows, dogs and horses.
    Jacobs RM; Lumsden JH; Taylor JA; Grift E
    Can J Vet Res; 1991 Apr; 55(2):150-4. PubMed ID: 1884294
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A solution to the problem of bilirubin interference with the kinetic Jaffé method for serum creatinine.
    Osberg IM; Hammond KB
    Clin Chem; 1978 Jul; 24(7):1196-7. PubMed ID: 657504
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Elimination of bilirubin interference on creatinine determination (kinetic Jaffé method) using bilirubin oxidase].
    Matsushita M; Maehata E; Aoki Y
    Rinsho Byori; 1986 Jun; 34(6):694-8. PubMed ID: 3747210
    [No Abstract]   [Full Text] [Related]  

  • 24. Interference of selected second- and third-generation cephalosporins with creatinine determination.
    Guay DR; Meatherall RC; Macaulay PA
    Am J Hosp Pharm; 1983 Mar; 40(3):435-8. PubMed ID: 6846351
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Kinetic serum creatinine assays. II. A critical evaluation and review.
    Bowers LD; Wong ET
    Clin Chem; 1980 Apr; 26(5):555-61. PubMed ID: 7020989
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Micro-method for determining serum bilirubin (author's transl)].
    Di Salvo C; Sambataro S; De Meo S
    Quad Sclavo Diagn; 1976 Mar; 12(1):90-103. PubMed ID: 1019294
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Kinetic immunological-turbidimetric determination of C-3 protein with a fast analyzer (author's transl)].
    Ebeling H
    J Clin Chem Clin Biochem; 1978 Mar; 16(3):191-5. PubMed ID: 650159
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Hitachi 917 analyzer.
    Al-Turkmani MR; Law T; Kellogg MD
    Clin Chim Acta; 2008 Dec; 398(1-2):75-7. PubMed ID: 18778699
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Enzymatic assay for creatinine with fixed-time kinetics on a centrifugal analyzer.
    Margrey M; Margrey K; Bruns DE; Boyd JC; Fortier GA; Renoe BW; Savory J
    Ann Clin Lab Sci; 1984; 14(4):298-303. PubMed ID: 6465833
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Colorimetric rate method for the determination of creatinine as implemented by the Beckman Creatinine Analyzer 2.
    Flores OR; Sun L; Vaziri ND; Miyada DS
    Am J Med Technol; 1980 Nov; 46(11):792-8. PubMed ID: 7246586
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [A fully enzymatic triglyceride determination in a continuous flow 12-channel analyzer (author's transl)].
    Liebich HM; Müller PH; Schmülling RM; Eggstein M; Stähler F; Weisshaar D
    J Clin Chem Clin Biochem; 1977 Sep; 15(9):503-8. PubMed ID: 925637
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Enzymic assay of creatinine in serum and urine with creatinine iminohydrolase and glutamate dehydrogenase.
    Tanganelli E; Prencipe L; Bassi D; Cambiaghi S; Murador E
    Clin Chem; 1982 Jul; 28(7):1461-4. PubMed ID: 7083556
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Determination of reference intervals for serum creatinine, creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffé method.
    Junge W; Wilke B; Halabi A; Klein G
    Clin Chim Acta; 2004 Jun; 344(1-2):137-48. PubMed ID: 15149882
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bilirubin and metamizol do not interfere with the randox enzymatic creatinine test. An evaluation of a new enzymatic creatinine determination method.
    Harmoinen AP
    Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):975-6. PubMed ID: 8986403
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [The determination of urea in plasma and serum by a urease/Berthelot method, adapted to the Greiner Electronic Selective Analyzer GSA II (author's transl)].
    Richterich R; Küffer H
    Z Klin Chem Klin Biochem; 1973 Dec; 11(12):553-64. PubMed ID: 4804158
    [No Abstract]   [Full Text] [Related]  

  • 36. Development and evaluation of a reagent carrier with a new reaction sequence for the determination of creatinine in blood, plasma, serum and urine.
    Carstensen CA; Nagel R; Knoll E; Wisser H; Weidemann G; Riesen WF; Seiler D; Nagel D
    Eur J Clin Chem Clin Biochem; 1993 May; 31(5):335-46. PubMed ID: 8357943
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Pretreatment of Fuller's earth with nitrogen.
    N'cho JS; Fofana I; Beroual A
    Heliyon; 2020 Mar; 6(3):e03643. PubMed ID: 32258486
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [An automated kinetic determination method for serum cholinesterase (EC 3.1.1.8) (author's transl)].
    Eberhard A; Kley R
    Z Klin Chem Klin Biochem; 1973 Apr; 11(4):152-4. PubMed ID: 4770618
    [No Abstract]   [Full Text] [Related]  

  • 39. [The influence of cephaloridine on several methods for the determination of creatinine (author's transl)].
    Raasch E; Kietzer I
    Arzneimittelforschung; 1979; 29(10):1544-6. PubMed ID: 583219
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [A kinetic method of determining creatinine using the Jaffé reaction].
    Lipitskaia IIa; Kotkina TI; Tarasov AV; Titov VN
    Lab Delo; 1989; (2):37-42. PubMed ID: 2467057
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.