365 related articles for article (PubMed ID: 6419029)
21. Surface dose for megavoltage photon beams outside the treatment field.
Starkschall G; St George FJ; Zellmer DL
Med Phys; 1983; 10(6):906-10. PubMed ID: 6419036
[TBL] [Abstract][Full Text] [Related]
22. Caesium-137 gamma-ray beams.
Burns JE
BJR Suppl; 1996; 25():39-45. PubMed ID: 9068355
[No Abstract] [Full Text] [Related]
23. The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams.
Almond PR; Xu Z; Li H; Park HC
Med Phys; 1995 Aug; 22(8):1307-14. PubMed ID: 7476718
[TBL] [Abstract][Full Text] [Related]
24. Experimental determination of the beam quality dependence factors, kQ, for ionization chambers used in photon and electron dosimetry.
Guerra AS; Laitano RF; Pimpinella M
Phys Med Biol; 1995 Jul; 40(7):1177-90. PubMed ID: 7568376
[TBL] [Abstract][Full Text] [Related]
25. Simplified TRS398 dosimetry protocol for dose determination in high-energy electrons beams.
Behin-Ain S; Lanzon P
Phys Med Biol; 2006 May; 51(9):2205-9. PubMed ID: 16625036
[TBL] [Abstract][Full Text] [Related]
26. The use of the ferrous sulphate dosimeter for intercomparison of absorbed dose from electron beams.
Chen WL; Chang SC
Med Phys; 1984; 11(3):335-7. PubMed ID: 6429501
[TBL] [Abstract][Full Text] [Related]
27. Surface doses for acrylic versus lead acrylic blocking trays for Co-60, 8-MV, and 17-MV photons.
Bova FJ; Hill LW
Med Phys; 1983; 10(2):254-6. PubMed ID: 6408367
[TBL] [Abstract][Full Text] [Related]
28. Effect of silicone gel breast prosthesis on electron and photon dose distributions.
Krishnan L; St George FJ; Mansfield CM; Krishnan EC
Med Phys; 1983; 10(1):96-9. PubMed ID: 6405147
[TBL] [Abstract][Full Text] [Related]
29. Dosimetric characterization of the 18-MV photon beam from the Siemens Mevatron 77 linear accelerator.
Palta JR; Meyer JA; Hogstrom KR
Med Phys; 1984; 11(5):717-24. PubMed ID: 6438461
[TBL] [Abstract][Full Text] [Related]
30. Use of a Victoreen 500 electrometer to determine ionization chamber collection efficiencies.
Almond PR
Med Phys; 1981; 8(6):901-4. PubMed ID: 6798399
[TBL] [Abstract][Full Text] [Related]
31. The HPA photon protocol and proposed electron protocol.
Pitchford WG
Radiother Oncol; 1985 Dec; 4(4):297-9. PubMed ID: 4081117
[No Abstract] [Full Text] [Related]
32. Revised code of practice for the dosimetry of 2 to 25 MV x-ray, and of caesium-137 and cobalt-60 gamma-ray beams.
Phys Med Biol; 1983 Oct; 28(10):1097-104. PubMed ID: 6417684
[No Abstract] [Full Text] [Related]
33. [Ionizing radiation sources for radioisotope teletherapy].
Mil'shteĭn RS
Med Radiol (Mosk); 1985 Oct; 30(10):80-6. PubMed ID: 4058283
[No Abstract] [Full Text] [Related]
34. Comment on clinical implementation of the AAPM's Task Group-51 protocol for calibration of high-energy photon and electron beams.
Rodgers JE; Niroomand-Rad A; Lundsten M
Med Phys; 2000 Aug; 27(8):1995-6. PubMed ID: 10984245
[No Abstract] [Full Text] [Related]
35. Partial tolerance and time dose fractionation values for common external beam radiation therapy schedules.
Hibbitts KR; Miller MP; Raeside DE; Bogardus CR
Radiol Technol; 1981; 52(5):533-42. PubMed ID: 6801724
[No Abstract] [Full Text] [Related]
36. Proposed definitions for isodose flatness and symmetry in clinical radiotherapy beams.
Galiano E; Joly T; Wiebe F
Appl Radiat Isot; 2004 Dec; 61(6):1361-6. PubMed ID: 15388134
[TBL] [Abstract][Full Text] [Related]
37. Standardisation of field-size specification in megavoltage radiotherapy.
Karzmark CJ; Sampiere VA; Stovall M
Br J Radiol; 1968 Sep; 41(489):712-3. PubMed ID: 4970951
[No Abstract] [Full Text] [Related]
38. Unwanted photon and neutron radiation resulting from collimated photon beams interacting with the body of radiotherapy patients.
Ing H; Nelson WR; Shore RA
Med Phys; 1982; 9(1):27-33. PubMed ID: 6804769
[TBL] [Abstract][Full Text] [Related]
39. AAPM Task Group 21 protocol: dosimetric evaluation.
Paul JM; Koch RF; Philip PC
Med Phys; 1985; 12(4):424-30. PubMed ID: 3929049
[TBL] [Abstract][Full Text] [Related]
40. [Practical application of optimization criteria for geometrical distributions of irradiation doses. II. Comparison between Co-60 radiation and 15 MeV photon radiation of a linear accelerator (author's transl)].
Amel-Zadeh A; Gremmel H; Hebbinghaus D; Ihnen E; Wendhausen H
Strahlentherapie; 1982 Apr; 158(4):224-6. PubMed ID: 6808712
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]