These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 6427569)

  • 1. Dosimetry characteristics of large wedges for 4- and 6-MV x rays.
    Wu A; Zwicker RD; Krasin F; Sternick ES
    Med Phys; 1984; 11(2):186-8. PubMed ID: 6427569
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric parameters of a modified set of wedges for use with asymmetric fields of a 6 MV linear accelerator.
    Niroomand-Rad A; Rodgers JE; Taylor P; Hames B
    Med Phys; 1994 Sep; 21(9):1405-8. PubMed ID: 7838051
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetry of large wedged high-energy photon beams.
    Podgorsak MB; Kubsad SS; Paliwal BR
    Med Phys; 1993; 20(2 Pt 1):369-73. PubMed ID: 8497224
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Monte Carlo study on internal wedges using BEAM.
    van der Zee W; Welleweerd J
    Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Using different sets of wedges: clinical applications, dosimetry and safety interlocks.
    DeSanti S; Muller-Runkel R
    Med Dosim; 1989 Dec; 14(4):237-43. PubMed ID: 2513825
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Beam-hardening effects of wedges on a spoiled 6 MV beam.
    Lee PC; Glasgow GP
    Med Dosim; 1994; 19(3):141-4. PubMed ID: 7818752
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.
    Bidmead AM; Garton AJ; Childs PJ
    Phys Med Biol; 1995 Mar; 40(3):393-411. PubMed ID: 7732070
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Photon beam skin dose analyses for different clinical setups.
    Kim S; Liu CR; Zhu TC; Palta JR
    Med Phys; 1998 Jun; 25(6):860-6. PubMed ID: 9650173
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wedge design and dosimetry for 25-MV x rays.
    Abrath FG; Purdy JA
    Radiology; 1980 Sep; 136(3):757-62. PubMed ID: 6773106
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric characteristics of wedged fields.
    Sidhu NP; Breitman K
    Med Dosim; 1994; 19(1):35-41. PubMed ID: 8003205
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A first order approximation of field-size and depth dependence of wedge transmission.
    Tailor RC; Followill DS; Hanson WF
    Med Phys; 1998 Feb; 25(2):241-4. PubMed ID: 9507486
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric characteristics of wedges mounted beyond the blocking tray.
    Ochran TG; Boyer AL; Nyerick CE; Otte VA
    Med Phys; 1992; 19(1):187-94. PubMed ID: 1620046
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Scattered photons from wedges in high-energy x-ray beams.
    Zhu TC; Bjärngard BE; Vadash P
    Med Phys; 1995 Aug; 22(8):1339-42. PubMed ID: 7476722
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An analysis of discrepancies encountered by the AAPM radiological physics center.
    Gagnon WF; Berkley LW; Kennedy P; Hanson WF; Shalek RJ
    Med Phys; 1978; 5(6):556-60. PubMed ID: 104139
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator.
    Patterson MS; Shragge PC
    Med Phys; 1981; 8(3):312-8. PubMed ID: 6798391
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Beam profiles along the nonwedged direction for large wedged fields.
    Chui CS; LoSasso T
    Med Phys; 1994 Nov; 21(11):1685-90. PubMed ID: 7891628
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multienergetic verification of dynamic wedge angles in medical accelerators using multichannel linear array.
    Kowalik A; Litoborski M
    Rep Pract Oncol Radiother; 2013; 18(4):220-34. PubMed ID: 24416557
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characteristics of Clinac-18 wedged fields for 10-MV x rays.
    Tolbert DD; Lane RG; Paliwal BR; Frost SW; Chin KB; Dercks J
    Med Phys; 1977; 4(5):419-22. PubMed ID: 409923
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Matching the 6-MV photon beam characteristics of two dissimilar linear accelerators.
    Marshall MG
    Med Phys; 1993; 20(6):1743-6. PubMed ID: 8309448
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of dosimetric characteristics of Siemens virtual and physical wedges.
    Zhu XR; Gillin MT; Jursinic PA; Lopez F; Grimm DF; Rownd JJ
    Med Phys; 2000 Oct; 27(10):2267-77. PubMed ID: 11099193
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.